1 Introduction
This document describes how to prepare the site-specific configuration used when installing Cloud Execution Environment (CEE).
Before installation, the CEE configuration files must be edited. The configuration file templates are included in the installation tarball. The files provide configuration for the following areas:
- Compute hardware
- Cloud Management Networks
- Networking and NTP
- Storage
- Identity and Access Management (IdAM)
1.1 Scope
Configurations are described in both this document and the System Dimensioning Guides. This has been verified against the Cloud Execution Environment reference configurations. Refer to the following documents:
This document describes the following parameter types:
| Mandatory parameters | These parameters must be configured before deployment. | |
| Optional parameters | These parameters can be changed for some configurations, as described in Section 3. Optional parameters not described in Section 3 are outside the scope of this document. | |
Storage is measured in gibibyte (GiB), tebibyte (TiB), and mebibyte (MiB) in this document. 1 GiB is equal to 230 bytes.
This guide describes the initial configurations needed before CEE deployment. For post-deployment configuration options, refer to the Runtime Configuration Guide.
1.1.1 Hardware Terminology
In the configuration file templates for all hardware configurations, a universal CEE terminology is used, which maps to the following hardware-specific terms:
|
CEE Term |
Definition |
Dell Rack Servers Term |
BSP (EBS) Term |
HDS Term |
|---|---|---|---|---|
|
CEE region |
Several blade servers or rack-mounted servers |
N/A |
N/A |
A vPOD with a set of ComputerSystems |
|
Shelf |
A collection of servers that shares a control switch |
Servers connecting to the same X440 Extreme switches |
Subrack |
N/A(1) |
|
Server |
A basic compute engine to host cloud applications in CEE Region |
Server |
Blade |
ComputerSystem |
|
Blade |
Logical/physical location of the server |
Logical definition that typically corresponds to the iDRAC IP addressing plan |
Defined by slot of Generic Ericsson Processor (GEP) blade in subrack |
Logical definition that corresponds to a ComputerSystem identified with a UUID |
(1) Only one shelf is to be configured for HDS, listing
all blades per vPOD.
1.2 Target Groups
This document is aimed at skilled professionals from the following groups:
- Ericsson field personnel
- Ericsson designers and test personnel
- Support organization personnel
1.3 Prerequisites
This section describes the site-specific configuration parameters that are to be collected and defined before the installation. The overall workflow is described in CEE Installation. Ensure that the following is available:
- A site-specific IP and VLAN plan, based on Reference [1].
- If applicable, the network entity that is managed by the OpenStack Neutron module of the CEE region to be installed.
- System dimensioning details, based on the hardware-relevant System Dimensioning Guide.
- Additional site-specific system information, required
to update the configuration file, including:
- The number of shelves in the system to be installed
- The number of blades installed in each shelf
- Configuration file templates in the CEE_RELEASE folder of the tarball:
- config.yaml.<hardware_platform>. In case of HDS deployment, both an SDN and a non-SDN template are available.
- Switch configuration templates (<switch_model>_switch.yaml) (for deployment with managed Extreme or CMX/CAX switches).
- Host network templates (host_nw_<hardware_platform>.yaml).
Additional host network templates are available for features that require them. See Section 1.3.1 and Section 2.5.9.
In case of HDS deployment, both SDN and non-SDN templates are available.
- Cabling scheme templates (for deployment with managed Extreme switches).
- Neutron configuration templates (neutron_ericsson_<neutron_template>.yaml).
- EMC storage username and password (for deployment with EMC ScaleIO).
- IP addresses for the external NTP servers.
For more information on the required tarball contents, see Section 1.3.1.
Use the config.yaml template that matches the hardware, that is, Dell multi-server, Dell single server, HDS, or BSP. For more information on the YAML files used for the reference configurations, see the following sections. Compare the examples in this document to the relevant part of the files. A file editor that can render indentations well (for example, UltraEdit) is recommended.
1.3.1 CEE Software Release Tarball
The CEE software release tarball is required for CEE installation and can be downloaded from the SW Gateway. The tarball consists of the following files:
- CXC1737883_4-<release>.tar
- CXC1737883_4-<release>.tar.md5
- CXC1737883_4-<release>.tar.sha1
Below is an example of the release tarball contents:
- Note:
- The contents of the release tarball may vary according to the release.
cee-CXC1737883_4-<release>.iso CEE_RELEASE/config.yaml.bsp CEE_RELEASE/config.yaml.dell CEE_RELEASE/config.yaml.dell-single_server CEE_RELEASE/config.yaml.hds-with-sdn CEE_RELEASE/config.yaml.hds-without-sdn CEE_RELEASE/config.yaml.hp CEE_RELEASE/update_groups.yaml.template CEE_RELEASE/cabling_scheme/2_x670v_hp.yaml CEE_RELEASE/cabling_scheme/2_x670v_dell.yaml CEE_RELEASE/cabling_scheme/4_x670v_dell.yaml CEE_RELEASE/cabling_scheme/4_x670v_hp.yaml CEE_RELEASE/cabling_scheme/4_x770_hp.yaml CEE_RELEASE/cabling_scheme/cax_bsp.yaml CEE_RELEASE/host_net_templates/host_nw_bsp.yaml CEE_RELEASE/host_net_templates/host_nw_bsp-bm-glance-on-storage-nics.yaml CEE_RELEASE/host_net_templates/host_nw_bsp-glance-on-storage-nics.yaml CEE_RELEASE/host_net_templates/host_nw_bsp_without_compute_storage.yaml CEE_RELEASE/host_net_templates/host_nw_dell-single-server.yaml CEE_RELEASE/host_net_templates/host_nw_dell.yaml CEE_RELEASE/host_net_templates/host_nw_dell-bm-glance-on-storage-nics.yaml CEE_RELEASE/host_net_templates/host_nw_dell-glance-on-storage-nics.yaml CEE_RELEASE/host_net_templates/host_nw_dell_without_compute_storage.yaml CEE_RELEASE/host_net_templates/host_nw_hds-with-sdn.yaml CEE_RELEASE/host_net_templates/host_nw_hds-with-sdn-glance-on-storage-nics.yaml CEE_RELEASE/host_net_templates/host_nw_hds-with-sdn_without_compute_storage.yaml CEE_RELEASE/host_net_templates/host_nw_hds-without-sdn.yaml CEE_RELEASE/host_net_templates/host_nw_hds-without-sdn-glance-on-storage-nics.yaml CEE_RELEASE/host_net_templates/host_nw_hds-without-sdn_without_compute_storage.yaml CEE_RELEASE/host_net_templates/host_nw_hp.yaml CEE_RELEASE/host_net_templates/host_nw_hp-bm-glance-on-storage-nics.yaml CEE_RELEASE/host_net_templates/host_nw_hp-glance-on-storage-nics.yaml CEE_RELEASE/host_net_templates/host_nw_hp_without_compute_storage.yaml CEE_RELEASE/neutron/neutron_ericsson_cmx.yaml CEE_RELEASE/neutron/neutron_ericsson_extreme.yaml CEE_RELEASE/neutron/neutron_ericsson_sdn_tight.yaml CEE_RELEASE/neutron/neutron_ericsson_user_spec.yaml CEE_RELEASE/scripts/install_vfuel.sh CEE_RELEASE/scripts/migrate_fuel.sh CEE_RELEASE/scripts/parseyaml.rb CEE_RELEASE/scripts/update_orchestrator.sh CEE_RELEASE/switch_config/2_x670v_switch.yaml CEE_RELEASE/switch_config/4_x670v_switch.yaml CEE_RELEASE/switch_config/4_x770_switch.yaml CEE_RELEASE/switch_config/cmx_switch.yaml |
1.4 Generated and Prefilled Passwords
Some generated passwords are stored in a separate file, /etc/openstack_deploy/user_secrets.yml on the Fuel node. The user_secrets.yml file contains passwords queried from Fuel, for example rabbitmq_password, galera_root_password.
As shown in Example 1, other passwords used by Ericsson components must be prefilled in /etc/openstack_deploy/user_secrets.yml on the Fuel node, or generated by /usr/share/ericsson-orchestration/scripts/pw-token-gen.py:
Example 1 user_secrets.yml
rabbitmq_password: "{{ fuel_generated.rabbit.password }}"
galera_root_password: "{{ fuel_generated.mysql.root_password }}"
keystone_admin_password: "{{ fuel_settings.editable.access.password.value }}"
keystone_admin_token: "{{ fuel_generated.keystone.admin_token }}"
neutron_galera_password: "{{ fuel_generated.quantum_settings.database.passwd }}"
neutron_service_password: "{{ fuel_generated.quantum_settings.keystone.
admin_password }}"
nova_service_password: '{{ fuel_generated.nova.user_password }}'
nova_metadata_proxy_secret: '{{ fuel_generated.quantum_settings.metadata.metadata_
proxy_shared_secret }}'
cinder_password: "{{ fuel_generated.cinder.user_password }}"
cmha_galera_password:
cmha_service_password:
watchmen_galera_password:
watchmen_service_password:
idam_ldap_root_password:
idam_ldap_anonymous_bind_password:
idam_ldap_manager_bind_password:
idam_ldap_sync_bind_password:
idam_user_vnxlf_vnx_key:
idam_user_vnxlf_galera_password:
zabbix_cee_user_password:1.5 Editing the YAML Files
1.5.1 Using Anchors and Aliases
The CEE configuration file is a YAML file. The YAML standard defines anchors and aliases, see section Anchors and Aliases in the YAML specification, Reference [4]. An anchor is used to attach a label to a section of the data structure, so the section can be referred by an alias. An anchor consists of a label prefixed with an & character: &label. An alias consists of a label prefixed with a * character: *label.
Example 2 YAML Anchors and Aliases
...
presets:
- &label1
key1: value11
key2: value12
- &label2
key1: value21
key2: value22
...
actual_use: *label2
...
An alias can be used to reference the data structure defined by the anchor.
The CEE configuration templates define the recommended settings for several parts of the configuration. Each of these settings is marked with an anchor that can be used to reference them with an alias at the place where they are used. For example, settings such as the Network Interface Controller (NIC) assignment are expected to be identical for each server. With the use of aliases, the same NIC assignment is referenced by each server definition.
1.5.2 Editing config.yaml in Windows
If the configuration file is edited in Windows, it is likely that the file contains CRLF characters. To remove CR characters (Linux only uses LF), run the following command after transferring the file to the Fuel master node:
$> sed -i.bak -e 's/\r//g' <CONFIG.FILE.NAME>
A backup of the original file with the name <CONFIG.FILE.NAME>.bak is also created.
2 Basic Parameter Settings
This section describes how to update config.yaml with site-specific parameters. The updated configuration is used as input to the automated installation. The placeholder <variables> in the config.yaml must be replaced with valid values based on the information in this section.
- Note:
- The indentation in the template files must be kept. Use the SPACE key (blanks) to make the indentation. TAB must not be used.
2.1 Region Name
The region_name parameter refers to the CEE region name. The parameter is included in config.yaml as follows:
Example 3 CEE Region Name
ericsson: ... region_name: <CEE Region Name> ...
<CEE Region Name> must be replaced by an OpenStack region name, with a maximum length of 14 characters. The CEE region name must not contain the underscore "_" character.
- Note:
- The OpenStack endpoints are deployed by Fuel where the region name cannot be specified, so all the OpenStack endpoints will be configured with the default region name RegionOne. This difference does not affect the operation of CEE. Contact the next level of maintenance support to change the region name manually after installation if it is required.
The CEE region name and an underscore (_) are prepended to the system names of the hardware switches, if the switches are configured. For hardware switch configuration, see Section 2.3, and Section 3.12.
- Note:
- Each switch name is a maximum of 17 characters long, and the resulting total string length must not exceed 32 characters.
2.2 Neutron Configuration
The neutron section in the configuration file templates enables configuration of the OpenStack networking module (Neutron) in CEE. The section is included in config.yaml as follows:
Example 4 Neutron Non-SDN Configuration
ericsson:
...
neutron:
mgmt_vip: 192.168.2.15
mgmt_subnetmask: 24
l2_vlan_start: <L2.VLAN.START>
l2_vlan_end: <L2.VLAN.END>
neutron_config_yaml_file: <neutron_CONFIG.yaml>
...Example 5 Neutron SDN Configuration
ericsson:
...
neutron:
mgmt_vip: 192.168.2.15
mgmt_subnetmask: 24
tunnel_id_start: <VXLAN.VNI.RANGE.START>
tunnel_id_end: <VXLAN.VNI.RANGE.END>
neutron_config_yaml_file: neutron_sdn_tight.yaml
...Change the configuration template values to reflect the site specific values:
mgmt_vip
mgmt_vip is the common IP for the Neutron server process. This value must be a valid IP in cee_ctrl_sp network static sub range.
mgmt_subnetmask
mgmt_subnetmask is consistent with the subnet mask size of the cee_ctrl_sp network.
l2_vlan_start and l2_vlan_end
The L2 VLAN range only applies to non-SDN deployments.
l2_vlan_start is the first element of the range for tenant VLAN IDs used for Neutron network segments.
l2_vlan_end is the last element of the range for tenant VLAN IDs used for Neutron network segments.
- Note:
- This VLAN range is only for CEE tenant traffic, it must not include any CEE service VLANs (for example, management and storage networks).
tunnel_id_start and tunnel_id_end
Tunnel ID only applies to SDN deployments.
tunnel_id_start is the first element of the VXLAN VNI range. The value must be an integer in the range of 1 – 16777216.
tunnel_id_end is the last element of the VXLAN VNI range. The value must be an integer in the range of 1 – 16777216 and larger than tunnel_id_start.
neutron_config_yaml_file
neutron_config_yaml_file is the name of the file containing the Neutron configuration parameters. The following templates can be used for Neutron:
- neutron_ericsson_user_spec.yaml: Used for all configurations excluding those with SDN or managed CMX, CAX or Extreme switches.
- neutron_ericsson_extreme.yaml: Used for Extreme traffic switches.
- neutron_ericsson_cmx.yaml: Used for BSP deployment of CEE.
- neutron_ericsson_sdn_tight.yaml: Used for deployment with SDN.
The following example is a Neutron BSP configuration:
Example 6 Neutron Configuration for BSP
ericsson:
...
neutron:
mgmt_vip: 192.168.2.15
mgmt_subnetmask: 24
l2_vlan_start: 130
l2_vlan_end: 3999
neutron_config_yaml_file: neutron_ericsson_cmx.yaml
...For more information on the Neutron configuration file configuration, see Section 3.10.
2.3 Hardware Switches
The hw_switches section describes the configuration to be deployed to the hardware switches during CEE region installation. The section can contain the following parameters:
Example 7 Hardware Switch Configuration
ericsson:
...
hw_switches:
initial_setup: <INITIAL_SETUP>
switching_scheme_yaml_file: <SWITCH.CONFIGURATION_FILE.yaml>
cabling_scheme_yaml_file: <CABLING.SCHEME_FILE.yaml>initial_setup
initial_setup specifies the initial setup of the hardware switches. The following values are valid:
- extreme, if using Extreme switch setup (Dell multi-server).
- cmx, if using CMX/CAX switches setup (BSP). If initial_setup is set to cmx, cabling_scheme_yaml_file is not applicable.
- None, if setting up unmanaged CEE switching (HDS without SDN, single server) or HDS with SDN configuration. If initial_setup is set to None, switching_scheme_yaml_file and cabling_scheme_yaml_file are not applicable.
- Note:
- Semi-managed switch configuration is not possible in CEE. The neutron_ericsson_user_spec.yaml Neutron configuration file can only be used if initial_setup is set to None.
switching_scheme_yaml_file
- Note:
- This keyword is only applicable if initial_setup is cmx or extreme.
The value of <SWITCH.CONFIGURATION_FILE.yaml> specifies the switch setup used:
- For Extreme switches, the following values are valid:
- 2_x670v_switch.yaml
- 4_x670v_switch.yaml
- 4_x770_switch.yaml
- For CMX/CAX switches on BSP, the following value is
valid:
- cmx_switch.yaml
The switch configuration file has to be aligned with the hardware setup. For more information, refer to the relevant hardware installation instructions: Dell PowerEdge R630 HW Installation. For information on how to configure the selected <switch_model>_switch.yaml file, see Section 2.3.1 (Extreme) or Section 2.3.2 (CMX).
cabling_scheme_yaml_file
- Note:
- This keyword is only applicable if initial_setup is extreme.
This parameter specifies the cabling schema used. The following values are valid:
- For Dell multi-server deployment:
- 2_x670v_dell.yaml
- 4_x670v_dell.yaml
The cabling configuration file has to be aligned with the hardware setup. For more information, refer to the relevant hardware installation instructions: Dell PowerEdge R630 HW Installation. For advanced hardware switch configuration options, see Section 3.12.
2.3.1 Configuring Extreme Switches
To configure the Extreme switches in multi-server deployment, the following networks need to be configured in the <switch_model>_switch.yaml file with site-specific values for both traffic switch A and B:
- subrack_ctrl_sp network for subrack management.
- cee_om_sp network for vCIC northbound communication.
- subrack_om_sp link network between the traffic switches and the Data Center Gateway (DC-GW), referred to as Border Gateway (BGW) in config.yaml).
For more information on these networks, see Section 2.6.
The structure of the configuration options is as follows:
Example 8 Update Switch IP Addresses
Switch A
switching:
-
...
mgmt_vrrp_config:
-
vip: 10.0.3.1/24
is_master: true
vlan: subrack_ctrl_sp
-
vip: VIP.OF.THE.VRRP/PREFIXSIZE
is_master: true
vlan: subrack_om_sp
...
mgmt_config:
vlans:
-
name: cee_ctrl_sp
tagged: true
-
name: subrack_ctrl_sp
ip: 10.0.3.2/24
tagged: true
bgw_config:
-
id: 1
vlans:
-
name: cee_om_sp
tagged: true
ip: <IP.OF.SWITCH-A/PREFIXSIZE>
-
name: subrack_om_sp
tagged: true
ip: IP.OF.THE.SWITCH/PREFIXSIZE
...
Switch B
switching:
-
...
mgmt_vrrp_config:
-
vip: 10.0.3.1/24
is_master: false
vlan: subrack_ctrl_sp
-
vip: VIP.OF.THE.VRRP/PREFIXSIZE
is_master: false
vlan: subrack_om_sp
...
mgmt_config:
vlans:
-
name: cee_ctrl_sp
tagged: true
-
name: subrack_ctrl_sp
ip: 10.0.3.3/24
tagged: true
bgw_config:
-
id: 2
vlans:
-
name: cee_om_sp
tagged: true
ip: <IP.OF.SWITCH-B/PREFIXSIZE>
-
name: subrack_om_sp
tagged: true
ip: IP.OF.THE.SWITCH/PREFIXSIZE
...mgmt_vrrp_config
The following parameters are needed:
- vip for subrack_ctrl_sp is the VRRP IP address of the traffic switches on subnet subrack_ctrl_sp.
- vip for subrack_om_sp is the VRRP IP address of the traffic switches on subnet subrack_om_sp (<VIP.OF.THE.VRRP/PREFIXSIZE>).
mgmt_config
The following parameters are needed:
- ip for subrack_ctrl_sp is the IP address of the traffic switch on subnet subrack_ctrl_sp, used as source address when the switch is synchronizing towards external NTP servers.
bgw_config
The following parameters are needed:
- ip for cee_om_sp is the IP address of the traffic switch on subnet cee_om_sp, used as source address when the switch is synchronizing towards external NTP servers (<IP.OF.SWITCH-A/PREFIXSIZE> / <IP.OF.SWITCH-B/PREFIXSIZE>).
- ip for subrack_om_sp is the IP address of the traffic switch on subnet subrack_om_sp, used as source address when the switch is synchronizing towards external NTP servers (<IP.OF.THE.SWITCH/PREFIXSIZE>).
2.3.2 Configuring CMX Switches on BSP
- Note:
- The same configuration and switch configuration templates are applicable for CMX and CAX switches.
This section describes CEE on BSP hardware. The configuration file template contains the following section:
Example 9 Hardware Switches
ericsson:
...
hw_switches:
initial_setup: cmx
switching_scheme_yaml_file: cmx_switch.yaml
... The switch configuration template cmx_switch.yaml contains the following section:
Example 10 Switch Configuration
switching: - model: cmx provider_vlan_start: <PROVIDER.VLAN.START> provider_vlan_end: <PROVIDER.VLAN.END> provider_name_prefix: provider_ switch_config: initial_backup: postCEETenant migrated_backup: postMigrateCEETenant
- provider_vlan_start: the first element of the range of VLAN tags to be used as segmentation IDs for Neutron network with provider extension.
- provider_vlan_end: the last element of the range of VLAN tags to be used as segmentation IDs for Neutron network with provider extension.
- provider_name_prefix: prefix of the VLAN names corresponding to the specified range. The VLANs are created in CMX switches during CEE installation.
- initial_backup: is the name of the BSP configuration backup saved by CEE installation script.
- migrated_backup: is the name of the BSP configuration backup that is created after vFuel is migrated inside the blade system.
2.3.3 Configuring Unmanaged Switch
This section describes unmanaged CEE switching. The configuration file template contains the following section:
Example 11 Unmanaged Hardware Switch
ericsson:
...
hw_switches:
initial_setup: None
... 2.4 Cloud Management
2.4.1 General Configuration
The Atlas northbound and southbound networks need to be configured in the cloud_mgmt section of config.yaml. Both the Atlas Northbound Interface (NBI) and the Atlas Southbound Interface (SBI) have to be configured with site-specific information. See the structure of the nbi and sbi subsections:
Example 12 Cloud Management Configuration
ericsson:
...
cloud_mgmt:
nbi:
name: <NETWORK.NAME>
tag: <VLAN.TAG> / <VXLAN.TAG>
cidr: <NETWORK.IP/PREFIXSIZE>
start: <FIRST.IP.TO.USE>
end: <LAST.IP.TO.USE>
gateway: <IP.OF.THE.GW>
ip: <NBI.IP.OF.ATLAS>
sbi:
name: <NETWORK.NAME>
tag: <VLAN.TAG> / <VXLAN.TAG>
cidr: <NETWORK.IP/PREFIXSIZE>
start: <FIRST.IP.TO.USE>
end: <LAST.IP.TO.USE>
gateway: <IP.OF.THE.GW>
ip: <SBI.IP.OF.ATLAS>
....
The following parameters are to be configured with unique values for NBI and SBI, respectively:
- name is the name of the Atlas northbound or southbound network.
- tag is the unique VLAN or VXLAN tag of the Atlas northbound or southbound network.
- cidr is the subnet of the NBI or SBI. All CIDR must be non-overlapping.
- start is the first northbound or southbound IP assigned to the Atlas Cloud Manager.
- end is the last northbound or southbound IP assigned to the Atlas Cloud Manager.
- gateway is the northbound or southbound IP on the DC-GW.
- ip is the northbound or southbound IP address of the Atlas Cloud Manager. This IP must be within range of the <FIRST.IP.TO.USE> and <LAST.IP.TO.USE> of the interface.
During the Atlas installation, there are two options available on how IP addresses are assigned to Atlas:
- The default option is to use the IP addresses defined in <NBI.IP.OF.ATLAS> and <SBI.IP.OF.ATLAS> to run an instance of Atlas.
- The other option is to assign IP addresses from the start–-end ranges. This can be used if the intention is to run several instances of Atlas.
- Note:
- <NETWORK.NAME>, <FIRST.IP.TO.USE>, <LAST.IP.TO.USE>, <NBI.IP.OF.ATLAS>, and <SBI.IP.OF.ATLAS> must always be defined, regardless of how Atlas is installed.
2.4.2 Additional Configuration for SDN Deployments
In SDN deployment, cloud_mgmt can be configured with either L3 VPN or L2 GW connectivity.
2.4.2.1 SDN Deployment with L3 VPN Connectivity
For SDN deployment with L3 VPN connectivity, configure the following extra cloud_mgmt parameters are needed:
Example 13 Cloud Management SDN Configuration with VPN
cloud_mgmt:
network_type: <NETWORK.TYPE>
vpn:
name: <VPN.NAME>
rd: <ROUTE.DISTINGUISHER>
export_rt: <EXPORT.ROUTE.TARGET>
import_rt: <IMPORT.ROUTE.TARGET>
network_type
The mechanism through which the Atlas northbound and southbound networks are implemented. The allowed value is vxlan.
vpn
A VPN has to be configured to provide connectivity for the Atlas VM. The following parameters are needed to create the VPN entity in the Cloud SDN Controller (CSC):
- name is a unique string value defining the name of the VPN. The length of the VPN name must not exceed the CSC REST API buffer size.
- rd is the Route Distinguisher of the VPN.
- export_rt is the export Route Target of the VPN. The value needs to be within quotation marks: "value"
- import_rt is the import Route Target of the VPN. The value needs to be within quotation marks: "value"
2.4.2.2 SDN Deployment with L2 GW Connectivity
For SDN deployment with L2 GW connectivity, configure the following extra cloud_mgmt parameters are needed:
Example 14 Cloud Management SDN Configuration with L2 GW
cloud_mgmt:
network_type: <NETWORK.TYPE>
nbi:
...
l2gw: <NBI.L2GW.FOR.ATLAS>
l2gw_vlan: <VLAN.TAG.FOR.L2GW>
sbi:
...
l2gw: <SBI.L2GW.FOR.ATLAS>
l2gw_vlan: <VLAN.TAG.FOR.L2GW>network_type
The mechanism through which the Atlas northbound and southbound networks are implemented. The allowed value is vxlan.
l2gw
The name of the Neutron L2 GW connected to the DC-GW. The L2 connectivity must be defined according to the section L2 Connectivity to DC-GW in the OpenStack Networking API in CEE with SDN. To use the same L2 GW for both southbound and northbound interfaces, provide the same l2gw name under both nbi and sbi. Otherwise, provide a different L2 GW name for each.
l2gw_vlan
The unique VLAN ID used to connect the Atlas NBI or SBI networks with L2 GW.
2.5 Server Configuration
2.5.1 Shelf and Blade Management
The shelf or blade management sections must be edited with site-specific information. Remove the unused shelves (including definitions for the unused shelf) from config.yaml, or add further shelves if needed.
Some shelves are excluded from the following example for readability. The exact structure of the shelf or blade management information is hardware dependent. The hardware-specific details are shown in the sections below the example.
- Note:
- The passwd and username parameters configured in this section are also used by fencing for out-of-band management access.
The shelf configuration options for BSP deployment are as follows:
Example 15 BSP Shelf Configuration
ericsson:
...
shelf:
-
id: 0
shelf_mgmt:
ip: <IP.SHELF.MANAGER>
name: cee_ctrl_sp
lct_ip: 10.0.10.2
bsp_tenant: CEE
passwd: <PASSWORD-SHELF.MANAGER>
username: <USERNAME.SHELF.MANAGER>
bsp_tenant: CEE
blade:
-
id: 1- Note:
- A shelf with id: 0 must be present in config.yaml and contain shelf_mgmt, even if no blades are allocated to it.
The following shelf manager information has to be updated:
- id is the subrack ID.
- ip is the IP address of the DMXC (BGCI) interface.
- passwd is the administrator password of the single shelf manager.
- username is the administrator username of the single shelf manager.
- bsp_tenant is the name of the BSP tenant used by the CEE installation. During the installation, CEE checks if the BSP tenant already exists on BSP. If the BSP tenant already exists, the installation script removes the existing configuration of the BSP tenant and reconfigures it according to CEE requirement.
The blade ID is the position of the blade, blade ID=(slot ID+1)/2. For example:
- Blade ID 1 is the blade in slot 1.
- Blade ID 2 is the blade in slot 3.
- Blade ID 5 is the blade in slot 9.
Dell
The shelf configuration options for Dell deployment are as follows:
Example 16 Dell Multi-Server Blade Configuration
ericsson:
...
shelf:
-
id: 0
blade:
-
id: 1
blade_mgmt:
ip: <IP.FIRST.SERVER>
name: subrack_ctrl_sp
passwd: <PASSWORD.FIRST.SERVER>
username: <USERNAME.FIRST.SERVER>
...
-
id: 2
blade_mgmt:
ip: <IP.SECOND.SERVER>
name: subrack_ctrl_sp
passwd: <PASSWORD.SECOND.SERVER>
username: <USERNAME.SECOND.SERVER>
...
The following blade manager information has to be updated:
- ip is the IP address of iDRAC in each server.
- passwd is the administrator password.
- username is the administrator username.
The blade ID is the position of iDRAC. For example:
The following shelf configuration options are required for HDS:
Example 17 HDS Shelf Configuration
ericsson:
...
shelf:
-
id: 0
shelf_mgmt:
type: HDS
api_url: https://<IP.TO.CCM.API>/<CUSTOMER.UUID>/<VPOD.UUID>
username: <USERNAME.DCC.VPOD>
passwd: <PASSWORD.DCC.VPOD>
blade:
-
id: 1
hw_uuid: <SERVER.UUID>
...- <IP.TO.CCM.API> is the IP address used for customer access to the HDS CCM API.
- <CUSTOMER.UUID> is the customer UUID of the vPOD owner.
- <VPOD.UUID> is the UUID of the vPOD.
- <USERNAME.DCC.VPOD> is the username for the vPOD where CEE is being deployed.
- <PASSWORD.DCC.VPOD> is the password for the vPOD where CEE is being deployed.
- <SERVER.UUID> is the UUID of the server used for all requests towards the CCM.
SDN Blade Configuration
Additional blade parameters are needed for SDN deployments on HDS versions earlier than 2.7 to configure HW-VTEP reachability on the compute hosts:
Example 18 SDN HW-VTEP Configuration
ericsson:
...
shelf:
-
id: 0
blade:
-
id: 1
hw_vtep_subnet: <HW_VTEP_SUBNET>
hw_vtep_gw: <HW_VTEP_GW>- Note:
- The hw_vtep_subnet and hw_vtep_gw values are mandatory on HDS versions earlier than 2.7, and can be retrieved from the switch. Contact the Data Center (DC) owner. On HDS 2.7 and later, the keys are ignored and the values are fetched from the Command Center Manager (CCM) API.
- hw_vtep_subnet is the HW-VTEP subnet address.
- hw_vtep_gw is the HW-VTEP gateway IP address, retrieved from the switch.
Unmanaged Server
- Note:
- Unmanaged CEE deployment is not fully supported with documented procedures.
The blade configuration options for unmanaged CEE are as follows:
Example 19 Unmanaged Server Configuration
shelf:
-
id: 0
cee_managed: false
blade:
-
id: 1
hw_uuid: <SERVER.UUID>
mac_assignment:
control0: <LEFT.MAC.ADDRESS>
control1: <RIGHT.MAC.ADDRESS>
Unmanaged server mode requires the servers to be discovered and preconfigured before running the installation. The cee_managed shelf configuration option needs to be set to false. The following blade configuration options have to be updated:
- hw_uuid is the UUID of the
server to be included in applicable alarms. The hw_uuid parameter is optional, but if used, it must be defined for all servers.
See Section 2.5.2.
- Note:
- This parameter only applies to HDS deployment.
- control0 is the MAC address of the primary boot NIC of the server.
- control1 is the MAC address of the alternate boot NIC (optional).
Managed ScaleIO Blade Configuration
To dedicate a blade to be part of the ScaleIO cluster in a managed ScaleIO solution, the role of the blade in the cluster has to be defined in the scaleio subsection of blade configuration. This section is optional and only has effect if the global scaleio parameters are defined in the storage section, see Section 2.9.1. The following blade.scaleio parameters are available:
Example 20 ScaleIO Blade Configuration Example
ericsson:
shelf:
blade
- id: ..
scaleio:
mode: dedicated
roles:
mdm:
gw:
tb:
sds:
- protection_domain: domain1
faultset: fs1
devices:
- name: /dev/sdb
pool: pool1
- name: /dev/disk/by-partlabel/scaleio_sds_1
pool: pool2
mode has the following available values:
- dedicated
- shared
Currently only the dedicated value is supported.
roles has the following available parameters:
- mdm is used to configure the blade as Meta Data Manager (MDM).
- tb is used to configure the blade as Tie-Breaker (TB) MDM.
- gw is used to configure the blade as ScaleIO Gateway (GW).
- sds is used to configure the blade as ScaleIO Data Server (SDS).
Multiple roles can be configured for a ScaleIO dedicated host, however, MDM and TB roles are mutually exclusive. The blade is configured with the combination of roles present in roles. For more information on each role, refer to the EMC ScaleIO Version 2.0.x User Guide.
- Note:
- The default configuration is a 5-node MDM cluster, consisting of three MDM and two TB servers. If there are more than three MDM or two TB servers defined, the extra nodes will be configured as standby MDM or standby TB, respectively.
For sds role, the following parameters need to be specified:
- protection_domain is the protection domain, as defined in the scaleio storage section.
- devices is the list of devices
to be used for storage. Each device has to be listed in the form of
a dictionary containing the following parameters:
- name is the persistent device
path. It is advised to use the /dev/disk/by-path of the device, as this path depends on the physical connection between
the disk and the storage controller, and so it can be collected after
Fuel installation on the kickstart server, with one blade powered
on. Fuel boots a bootstrap image on the blade, where the /dev/disk/by-path IDs are the same as the post-deployment
IDs. Issue the following command to retrieve the path for each device:
find /dev/disk/ |grep sas|grep -v part |sort | ⇒ xargs sudo /sbin/hdparm -I | ⇒ grep 'Serial Number\|Model Number\|path'
find /dev/disk/ |grep sas|grep -v part |sort | xargs sudo /sbin/hdparm -I | grep 'Serial Number\|Model Number\|path'
- pool is the name of the pool where the device belongs. The storage pools are defined in the scaleio storage section.
- Note:
- Make sure that the disk devices configured for ScaleIO are removed from the RAID configuration.
- name is the persistent device
path. It is advised to use the /dev/disk/by-path of the device, as this path depends on the physical connection between
the disk and the storage controller, and so it can be collected after
Fuel installation on the kickstart server, with one blade powered
on. Fuel boots a bootstrap image on the blade, where the /dev/disk/by-path IDs are the same as the post-deployment
IDs. Issue the following command to retrieve the path for each device:
- faultset is an optional parameter
used to configure Fault Sets.
- Note:
- There are specific conditions to be met when configuring Fault Sets for SDSs. For more information on Fault Sets, refer to the Fault Sets section in the EMC ScaleIO Version 2.0.x User Guide.
In configurations using managed Extreme switches (Dell multi-server deployments), the cabling scheme YAML file must also be updated according to the allocation of ScaleIO ports in the traffic switch. The ScaleIO ports have the value usage: storage.
Example 21 ScaleIO Cabling Scheme Configuration for Extreme Switches
cabling_scheme:
shelves:
- blades:
- blade_id: 1
network interfaces:
- {nic_id: 1, switch_id: 1, switch_port: 3, usage: storage}
- {nic_id: 2, switch_id: 2, switch_port: 3, usage: storage}
- {nic_id: 3, switch_id: 1, switch_port: 4, usage: storage}
- {nic_id: 4, switch_id: 2, switch_port: 4, usage: storage}
2.5.2 Compute Hosts
Compute hosts are defined as a list of blades within each shelf. Each compute host must have an ID that corresponds to the physical/logical location of the server, see Section 1.1.1. Assignment of physical NIC devices to different CEE networks must be defined for each server. Memory (hugepages), CPU, and storage must also be allocated to different resource owners. The allocation of these resources is controlled through the configuration file.
A compute host can contain vCIC or vFuel VMs, or both. The allocation of resources depends on whether the host contains these infrastructure VMs or not.
hw_uuid
- Note:
- For HDS deployment, hw_uuid is a mandatory blade parameter to be configured for CCM communication, see HDS.
Certain CEE alarms contain the UUID of the compute host associated with the alarm. The UUID can be used to correlate CEE alarms with alarms generated by the lower-layer server management tools. By default, the UUID of each compute blade is obtained automatically during CEE install by running the following command:
dmidecode --string system-uuid
hw_uuid is an optional parameter for servers. If it is defined in config.yaml, the applicable alarms show the specified UUID instead of the default, automatically obtained one. If hw_uuid is used, it must be defined for all servers. If hw_uuid is not defined in config.yaml, the default auto value is assumed. The UUID can be assigned as follows:
Example 22 Hardware System UUID Assignment
ericsson:
...
blade:
-
id: 2
hw_uuid: <SERVER.UUID>
...
-
id: 3
hw_uuid: <SERVER.UUID>
...
The value of the hw_uuid parameter must be either a valid UUID or auto.
2.5.3 Virtual Cloud Infrastructure Controller (vCIC)
In a multi-server deployment, three compute hosts must be configured to host a vCIC. In a single server deployment, the single compute host must be configured to host a vCIC.
To contain a vCIC, the corresponding blade must contain the virt key with a data structure that defines a vCIC as shown in the examples in the previous subsections. In addition, the blade definition must contain resource reservations for hugepages, CPU, and disk storage suitable for vCIC.
2.5.4 Virtual Fuel
In a multi-server deployment, two compute hosts must be configured to be able to host a vFuel. In a single server deployment, while the vFuel VM is associated with the compute host, it remains on the kickstart server and does not migrate to the compute host.
To be able to contain a vFuel, the blade definition must contain resource reservations for hugepages, CPU, and disk storage suitable for vFuel. In addition, one of the two blade definitions must contain the vfuel key with an empty string as its value (see the previous sections for examples).
2.5.5 NIC Assignment
Each blade must have a nic_assignment section to define which physical NIC to use for control, storage, and data traffic. Each NIC is defined by its PCI address. The actual mapping depends on the cabling of the server.
The configuration template contains a list of predefined NIC assignments for supported hardware assuming the Ericsson-recommended cabling scheme. Predefined NIC assignments are listed in nic_assignments and each setting is labeled by an anchor. Normally, it is sufficient to refer to the appropriate predefined NIC assignment by using an alias in the blade definition.
Example 23 NIC Assignment of a Dell Server
ericsson:
...
blade:
-
id: 2
...
nic_assignment: *DELL_630_OEM_nic_assignment
....
Example 24 NIC Assignment of an Unmanaged Server
shelf:
cee_managed : false
blade:
id: 1
hw_uuid: 4c4c4544-0030-3310-8039-b8c04f423232
nic_assignment: *DELL_620_nic_assignment
mac_assignment:
control0: ec:f4:bb:c1:27:d4
control1: ec:f4:bb:c1:27:d5
- Note:
- If cee_managed is true, the CEE is managed and the mac_assignment fields are ignored.
If the alias for a blade used in nic_assignment is not appropriate for the hardware, change the alias to refer to the relevant setting. The predefined values are found in the nic_assignments section of the configuration template. Refer to one of the available predefined settings by using its alias. If the hardware is not listed in nic_assignments, add a new NIC mapping to the list. See Section 3.6 for information on how to define a new NIC mapping.
2.5.6 Memory Allocation
The physical memory of a server is partitioned into memory pages. Pages can have three different sizes: 4 KiB, 2 MiB, and 1 GiB. The 2 MiB and 1 GiB pages are called hugepages. In CEE, the memory is used as follows:
- 4 KiB pages are used by the host OS (hypervisor).
- 2 MiB pages are used by Open Virtual Switch (OVS) as buffers for Data Plane Development Kit (DPDK).
- 1 GiB pages are used for the memory of tenant and infrastructure VMs (vCIC and vFuel).
The memory to be allocated in hugepages is defined in config.yaml for each blade. The remainder of the physical memory that is not allocated in hugepages is accessible in 4 KiB pages. If using the keyword auto for the VM hugepage allocation, the installer calculates the hugepage count and ensures that they are evenly split between multiple NUMA nodes. If the number of hugepages is specified for VMs, the installer will reserve them evenly between NUMA nodes if an even number is configured. In case an odd number is configured, NUMA node 0 will be configured with one more hugepage than NUMA 1.
To reserve hugepages on a compute host, the reservedHugepages section of the corresponding blade must be filled in.
Example 25 Hugepage Reservations for Three Different Blades in BSP
ericsson:
...
blade:
-
id: 1
nic_assignment: *BSP_GEP7_nic_assignment
reservedHugepages: *reservedHugepages_with_vcic_and_vfuel
reservedCPUs: *reservedCPUs_with_vcic_and_vfuel
reservedDisk: *reservedDisk_for_vcic_and_vfuel
virt:
cic:
id: 1
-
id: 2
nic_assignment: *BSP_GEP5_nic_assignment
reservedHugepages: *reservedHugepages_with_vcic_and_vfuel
reservedCPUs: *reservedCPUs_with_vcic_and_vfuel
reservedDisk: *reservedDisk_for_vcic_and_vfuel
virt:
cic:
id: 2
-
id: 3
nic_assignment: *BSP_GEP5_nic_assignment
reservedHugepages: *reservedHugepages_with_vcic
reservedCPUs: *reservedCPUs_with_vcic
reservedDisk: *reservedDisk_for_vcic
virt:
cic:
id: 3
-
id: 4
nic_assignment: *BSP_GEP5_nic_assignment
reservedHugepages: *reservedHugepages
reservedCPUs: *reservedCPUs
...
The amount of memory to reserve in hugepages depends on whether the compute host contains a vCIC or vFuel, or both. The examples above illustrate different alternatives. For the recommended hugepage reservations, refer to the relevant System Dimensioning Guide:
Predefined hugepage reservations are listed in the reservedHugepages section. Refer to one of the available predefined settings by using an alias as shown in the examples.
The installer calculates the amount of memory to be allocated for each component and verifies its consistency with the total nominal memory of the physical server. The managed memory reservation can be configured using the compute_os_reserved_mem parameter, with the default value of 6 GiB. 6 GiB of managed memory is the minimum requirement. For the recommended allocation, refer to the Multi-Server System Dimensioning Guide, CEE 6.
- Note:
- The amount of unmanaged memory depends on the nominal physical memory of the server. The installer reads this value directly from the compute host.
The compute_os_reserved_mem configuration parameter is a dictionary with the nominal physical memory amount of the server as key, and the amount of memory to reserve as host OS managed memory as value. The values are in GiB. This parameter is defined globally for all blades in the CEE region. The configuration templates contain the following values:
compute_os_reserved_mem: {64: 6, 128: 6, 192: 6, 256: 6, 320: 6, 384: 6, 448: 6, 512: 6}
compute_os_reserved_mem: {64: 6, 128: 6, 192: 6, 256: 6, 320: 6, 384: 6, 448: 6, 512: 6}
The example above shows the minimum required values. These parameters are defined globally and are valid for all blades.
The default vCIC swap space is 512 MiB. The swap space can be changed by setting the vcic_swap_size optional parameter. The value is expressed in MiB. For example, the following setting increases the swap space to 5 GiB:
vcic_swap_size: 5120
2.5.7 CPU Allocation
The CPUs of a compute host can be reserved for different purposes, such as OVS, tenant VMs, and infrastructure VMs (vCIC and vFuel). Reservation of the CPUs means that the reserved CPUs are used exclusively by the owner of the reservation. Reserved CPUs are isolated, which means that the kernel scheduler does not schedule processes to run on these CPUs by itself. The CPUs not reserved for these owners remain non-isolated and regular processes of the host OS are scheduled on these CPUs.
To reserve CPUs on a compute host, the reservedCPUs section of the corresponding blade must be filled in.
Example 26 CPU Allocation
ericsson:
...
-
id: 3
blade_mgmt:
...
nic_assignment: *DELL_630_OEM_nic_assignment
reservedHugepages: *reservedHugepages_with_vcic
reservedCPUs: *reservedCPUs_with_vcic
reservedDisk: *reservedDisk_for_vcic
virt:
cic:
id: 3
-
id: 4
blade_mgmt:
...
nic_assignment: *DELL_630_OEM_nic_assignment
reservedHugepages: *reservedHugepages
reservedCPUs: *reservedCPUs
-
id: 5
blade_mgmt:
...
nic_assignment: *DELL_630_OEM_nic_assignment
reservedHugepages: *reservedHugepages_with_vfuel
reservedCPUs: *reservedCPUs_with_vfuel
reservedDisk: *reservedDisk_for_vfuel
vfuel: ""
...
If the compute host contains a vCIC or vFuel, or both, CPUs must be reserved for those as well. The examples above illustrate different alternatives. For the recommended CPU reservations, refer to the relevant System Dimensioning Guide. The CPU reservation anchors are predefined in the reservedCPUs section of the configuration template. Refer to one of the available predefined settings by using an alias, as shown in the examples.
- Note:
- The default OVS and VM CPU reservation uses automatic CPU allocation in multi-server configurations but uses manual CPU allocation for single server deployments. See Section 3.1 for details on the supported CPU allocation methods.
2.5.8 Disk Reservation
Storage space must be reserved on compute hosts that contain vCIC or vFuel. Use the reservedDisk section for reserving disk storage on a blade. Such disk reservation is not needed on compute hosts that do not contain infrastructure VMs.
Example 27 Disk Reservation for vCIC and vFuel
ericsson:
...
-
id: 1
...
nic_assignment: *DELL_630_OEM_nic_assignment
reservedHugepages: *reservedHugepages_with_vcic
reservedCPUs: *reservedCPUs_with_vcic
reservedDisk: *reservedDisk_for_vcic
virt:
cic:
id: 2
-
id: 2
...
nic_assignment: *DELL_630_OEM_nic_assignment
reservedHugepages: *reservedHugepages_with_vfuel
reservedCPUs: *reservedCPUs_with_vfuel
reservedDisk: *reservedDisk_for_vfuel
vfuel: ""
...
For the correct vFuel disk size value, refer to the relevant System Dimensioning Guide. The disk size value has to be given in GiB, with "G" appended after the value.
Example 28 vFuel Disk Size 80 GiB
ericsson:
...
- &reservedDisk_for_vfuel
- owner: vfuel
size: 80G
...
Or...
- &reservedDisk_for_vcic_and_vfuel
- owner: vfuel
size: 80G
...
2.5.9 Host Networking
The used host networking YAML file must correspond to the used hardware configuration.
Example 29 Host Networking in Dell Multi-Server Configuration
host_networking:
template_yaml_file: host_nw_dell.yaml
In case of HDS deployment, the host networking template must be selected based on whether CEE is deployed with or without SDN TI.
The following host networking templates are available:
Standard networking templates
- host_nw_bsp.yaml
- host_nw_dell.yaml
- host_nw_dell-single-server.yaml
- host_nw_hds-with-sdn.yaml
- host_nw_hds-without-sdn.yaml
- host_nw_hp.yaml
Networking templates for deployment without SAN connectivity
To deploy compute servers (not hosting a vCIC) in the whole CEE region without SAN connectivity, the following templates are available for the multi-server platforms:
- host_nw_bsp_without_compute_storage.yaml
- host_nw_dell_without_compute_storage.yaml
- host_nw_hds-with-sdn_without_compute_storage.yaml
- host_nw_hds-without-sdn_without_compute_storage.yaml
- host_nw_hp_without_compute_storage.yaml
The compute servers that are not hosting a vCIC will not have storage interfaces (storage switching domain) configured. The surplus interfaces can be used for other purposes, such as PCI passthrough (see Section 3.8), SR-IOV Physical Function passthrough (see Section 3.8), or SR-IOV (see Section 3.7). Use the PCI addresses of the unused storage interfaces for SR-IOV, SR-IOV Physical Function passthrough, or PCI passthrough at interface configuration.
Networking templates for deployment with Glance on storage network
To deploy CEE with Glance on the storage network, the following templates are available:
- host_nw_bsp-glance-on-storage-nics.yaml
- host_nw_dell-glance-on-storage-nics.yaml
- host_nw_hds-with-sdn-glance-on-storage-nics.yaml
- host_nw_hds-without-sdn-glance-on-storage-nics.yaml
- host_nw_hp-glance-on-storage-nics.yaml
- Note:
- The templates host_nw_bsp-bm-glance-on-storage-nics.yaml, host_nw_dell-bm-glance-on-storage-nics.yaml, and host_nw_hp-bm-glance-on-storage-nics.yaml are not supported for commercial use.
For more information on configuring Glance on the storage network, see Section 2.6.4.
2.6 Networks
The networks section must be edited with site-specific information. See the following example for network configurations:
Example 30 Network Configuration
ericsson:
...
networks:
-
name: cee_om_sp
mos_name: public
tag: <VLAN.TAG>
enable_ntp: true
cidr: <NETWORK.IP/PREFIXSIZE>
start: <FIRST.IP.TO.USE>
end: <LAST.IP.TO.USE>
gateway: <IP.OF.THE.GW>The network fuel_ctrl_sp is used for PXE boot of compute hosts (host OS) and vCIC nodes. For information on how to change this network, see Section 3.17.
The following networks have to be configured based on hardware deployment:
|
Network name |
Dell multi-server |
Single server | ||
|
N/A |
to be configured |
N/A |
to be configured | |
|
N/A |
to be configured |
N/A |
N/A | |
|
to be configured |
to be configured |
to be configured |
to be configured | |
|
cee_ctrl_sp |
to be configured |
preconfigured |
to be configured |
preconfigured |
|
iscsi_san_pda |
to be configured |
preconfigured |
to be configured |
N/A |
|
iscsi_san_pdb |
to be configured |
preconfigured |
to be configured |
N/A |
|
swift_san_sp |
to be configured |
preconfigured |
to be configured |
N/A |
|
migration_san_sp |
to be configured |
preconfigured |
to be configured |
N/A |
|
to be configured |
N/A |
N/A |
N/A |
- Note:
- In case of HDS and BSP deployment, the VLAN tag has to be configured for all relevant networks above.
For more information on configuring these networks, see Section 2.6.1 and the site-specific IP and VLAN plan.
If using ScaleIO, additional networks must be configured, see Section 2.6.2.
If Glance is configured on the storage network, the network glance_san_sp must be configured, see Section 2.6.4.
Additionally, the following networks have to be configured for deployments with SDN:
For more information on configuring the SDN networks, see Section 2.6.3.
2.6.1 Hardware-dependent Network Configuration
subrack_ctrl_sp
- Note:
- The subrack_ctrl_sp network is used in case of non-Ericsson hardware configurations.
The network subrack_ctrl_sp is used for subrack management. The VLAN is used to monitor and manage the server blades. This is done regardless of whether the blade is powered on, or if an operating system is installed or functional. Update tag with the correct VLAN tag, and cidr with the IP address in the subrack_ctrl_sp network used by Fuel.
The start, end, and mos_name parameters have to be configured for the CM-HA fencing feature, see Section 2.17.
Example 31 Subrack Management
ericsson:
...
networks:
...
-
name: subrack_ctrl_sp
mos_name: subrack_ctrl_sp
tag: <VLAN.TAG>
vr: subrack_om
ipforwarding: true
cidr: <IP.IN.FUEL/PREFIXSIZE>
start: <FIRST.IP.TO.USE>
end: <LAST.IP.TO.USE>
...
- tag is the VLAN tag of subrack management. The VLAN is used to monitor and manage the server blades. This is done regardless of whether the blade is powered on, or if an operating system is installed or functional.
- cidr is the IP address used by Fuel in the subrack_ctrl_sp network.
- start is the first IP address in range for the subnet offered to the vCIC for the CM-HA fencing feature.
- end is the last IP address in range for the subnet offered to the vCIC for the CM-HA fencing feature.
Additional parameters must be set for subrack_ctrl_sp in the specific <switch_model>_switch.yaml file, see Section 2.3.1.
subrack_om_sp
- Note:
- The subrack_om_sp is used in case of non-Ericsson multi-server configurations.
The network subrack_om_sp is used as a link network between the traffic switches and the BGWs (DC-GWs). Subrack management traffic is routed over this network.
Example 32 Network subrack_om_sp
ericsson:
...
networks:
...
-
name: subrack_om_sp
tag: <VLAN.TAG>
vr: subrack_om
cidr: <NETWORK.IP/PREFIXSIZE>
gateway: <IP.OF.THE.GW>
ipforwarding: true
...
- tag is the VLAN tag of subrack management.
- cidr is the subnet of subrack management.
- gateway is the IP of the gateway.
Additional parameters must be set for subrack_om_sp in the specific <switch_model>_switch.yaml file, see Section 2.3.1.
cee_om_sp
The network cee_om_sp is used for vCIC northbound communication:
Example 33 vCIC Northbound Communication
ericsson:
...
networks:
...
-
name: cee_om_sp
mos_name: public
tag: <VLAN.TAG>
enable_ntp: true
cidr: <NETWORK.IP/PREFIXSIZE>
start: <FIRST.IP.TO.USE>
end: <LAST.IP.TO.USE>
gateway: <IP.OF.THE.GW>
...
The number of dynamically assigned IP addresses inside cee_om_sp in the range FIRST.IP.TO.USE to LAST.IP.TO.USE must be at least seven, including the endpoints:
- The first, second, and third IP addresses in the range are individual addresses of the three vCICs.
- The fourth IP address in the range is always the vRouter address.
- The fifth address in the range is the CIC HA proxy.
- The last two IP addresses are reserved for vCIC internal use.
- Note:
- For HDS configuration, the kickstart server IP also has to be provided, using the kickstart key.
hds_agent
The network used for HDS In-band Metrics Collection. The following parameters need to be configured:
- tag is the VLAN for the hds_agent network.
- cidr is the IP range of the hds_agent network.
- start is the first management IP address.
- end is the last management IP address.
2.6.2 ScaleIO Network Configuration
If using ScaleIO, the ScaleIO frontend networks must be configured. A pair of back-end networks can optionally be configured for managed ScaleIO. For more information on ScaleIO configuration, see Section 2.9.1.
- Note:
- The host networking configuration has to be aligned with
the ScaleIO cluster:
- In case of CEE-managed ScaleIO, the mos_name of the configured networks must be added to the global scaleio configuration.
- In case of deploying CEE with unmanaged ScaleIO, the mos_name for each configured ScaleIO network must be manually configured in the external ScaleIO cluster.
Establishing connectivity between an unmanaged ScaleIO cluster and CEE is outside the scope of the customer documentation. Contact next level of support. The following connectivity must be configured:
- L2 connectivity between the SDCs and the SDSs
- L3 connectivity between the vCICs and the ScaleIO gateway
- L3 connectivity between the compute hosts and the ScaleIO gateway
- L2 and L3 connectivity between the compute hosts and the MDM
The configuration templates contain configuration details for both ScaleIO frontend and back-end networks, however, a VLAN tag has to be added to each configured ScaleIO network.
The following ScaleIO frontend networks must be configured:
sio_fe_san_pda
The left ScaleIO frontend network used for storage traffic.
- mos_name is scaleio-frontend-left
sio_fe_san_pdb
The right ScaleIO frontend network used for storage traffic.
- mos_name is scaleio-frontend-right
Optionally, the following ScaleIO back-end networks can be configured:
- Note:
- Backend network configuration only applies to managed ScaleIO.
sio_be_san_pda
The left ScaleIO back-end network for SDC to SDS, MDM to MDM, MDM to SDS, and MDM to SDC traffic.
- mos_name is scaleio-backend-left
sio_be_san_pdb
The right ScaleIO back-end network for SDC to SDS, MDM to MDM, MDM to SDS, and MDM to SDC traffic.
- mos_name is scaleio-backend-right
For more information about ScaleIO network configuration, refer to the ScaleIO Architecture Description.
2.6.3 SDN Network Configuration
The following additional networks have to be configured for SDN:
sdnc_internal_sp
sdnc_internal_sp is the network used for CSC internal communication. The CSCs running on the three vCICs use this network to communicate with each other and form a cluster.
Example 34 sdnc_internal_sp Configuration
name: sdnc_internal_sp
mos_name: mos-sdnc-int
tag: <VLAN.TAG>
cidr: <NETWORK.IP/PREFIXSIZE>
start: <START.IP>
end: <END.IP>
mip: <MOVABLE.IP.QUAGGA>
mip2: <MOVABLE.IP.BGP_MASTER>mip and mip2 are the movable IPs of the sdnc_internal_sp network, used as single access IPs for all three vCICs.
mip is attached to the Quagga service and is used for OpenDaylight (ODL) to Quagga communication.
mip2 is attached to the BGP master resource and is used for Quagga to ODL communication. The ODL service runs in active-active-active mode on the three vCICs, but only one ODL instance has BGP as master. The ODL service will open port 6644 in the vCIC where BGP is master within the ODL service.
Both values must be:
sdnc_sbi_sp
sdnc_sbi_sp is the management network used for communication between the CSC and the Cloud SDN Switches (CSSs). sdnc_sbi_sp carries the OVSDB and Openflow traffic.
Example 35 sdnc_sbi_sp Configuration
name: sdnc_sbi_sp
mos_name: mos-sdnc-sbi
tag: <VLAN.TAG>
cidr: <NETWORK.IP/PREFIXSIZE>
start: <START.IP>
end: <END.IP>sdnc_sig_sp
sdnc_sig_sp is the network used for Border Gateway Protocol (BGP) traffic between the CSCs and the DC-GW.
Example 36 sdnc_sig_sp Configuration
name: sdnc_sig_sp
mos_name: mos-sdnc-sig
tag: <VLAN.TAG>
cidr: <NETWORK.IP/PREFIXSIZE>
start: <START.IP>
end: <END.IP>
mip: <MOVABLE.IP.EXTRENAL.CONNECTIVITY>
gateway: <IP.OF.THE.GATEWAY>
bgp_gateway: [<BGP.GATEWAY.1.IP>, <BGP.GATEWAY.2.IP>]
bgp_neighbour: [<BGP.NEIGHBOUR.1.IP>, <BGP.NEIGHBOUR.2.IP>]- mip is the movable IP of
the sdnc_sig_sp network, used as a single
access IP for all three vCICs. The mip is
attached to the Quagga service and is used for communicating with
the DC-GW for external connectivity. The value of this parameter must
be:
- Inside the cidr range
- Outside the start – end range
- bgp_gateway is a list of the DC-GW A and DC-GW B interface addresses in the site-specific IP and VLAN plan.
- bgp_neighbour is a list of the BGP neighbor addresses. The length of the list must be equal to that of bgp_gateway.
2.6.4 Glance on Storage Network Configuration
Glance can be optionally configured on storage network, by configuring the glance_san_sp network.
- Note:
- If glance_san_sp is configured, the appropriate host networking template must be selected, see Section 2.5.9.
glance_san_sp is used for Glance image transfer traffic from the vCICs to the compute hosts. The Glance API on each vCIC use this network to communicate with each other and form a cluster. The Swift internal and admin endpoints use a virtual IP address on this network.
Example 37 glance_san_sp Configuration
name: glance_san_sp
mos_name: glance
tag: <VLAN.TAG>
cidr: <NETWORK.IP/PREFIXSIZE>
start: <START.IP>
end: <END.IP>The following parameters have to be configured, based on the site-specific IP and VLAN plan, Reference [1]:
- tag is the VLAN for the glance_san_sp network.
- cidr is the subnet of the glance_san_sp network.
- start is the first IP address in range for the subnet offered to the vCIC and compute nodes for Glance on storage network.
- end is the last IP address in range for the subnet offered to the vCIC and compute nodes for Glance on storage network.
Refer to the Multi-Server System Dimensioning Guide, CEE 6.
2.7 Configure NTP
The ntp_config section contains NTP servers accessible by the vCIC. The section has to be updated with site-specific information.
Example 37 NTP Configuration
ericsson:
...
ntp_config:
servers: [<NTP.SERVER.1.IP>, <NTP.SERVER.2.IP>, <NTP.SERVER.3.IP>, <NTP.SERVER.4.IP>]
orphan_mode_stratum: <ORPHAN.MODE.STRATUM>
...
Example 38 NTP Configuration
ericsson:
...
ntp_config:
servers: [<NTP.SERVER.1.IP>, <NTP.SERVER.2.IP>, <NTP.SERVER.3.IP>, <NTP.SERVER.4.IP>]
orphan_mode_stratum: <ORPHAN.MODE.STRATUM>
...
Define up to four external NTP server IP addresses. A minimum of one NTP server IP address is required for deployment, but four are recommended for CEE operation. For example, servers: [IP-ADDRESS.FOR.NTP.SERVER-1, IP-ADDRESS.FOR.NTP.SERVER-2], IP-ADDRESS.FOR.NTP.SERVER-3].
When the NTP server running on one of the compute nodes enters NTP Orphan mode, the value of the parameter orphan_mode_stratum is used as stratum by that NTP server. To configure a correct value, the following criteria must be fulfilled:
- The value is in the range of 2 through 14.
- The value exceeds N+2 or be equal to N+2, where N is the maximum stratum of the upstream NTP servers. The upstream NTP servers are the NTP external sources for the CEE region.
2.7.1 NTP Authentication
The ntp_config section contains NTP authentication setup. The authentication can be set up between the compute host hosting the vCIC and the CIC upstream NTP servers.
Example 39 NTP Authentication
ericsson:
...
ntp_config:
...
authentication: None
...
To enable authentication towards the NTP servers upstream of the compute host that hosts the vCIC, set the md5 to the supported authentication method. Currently, the only available encryption method is md5.
Example 40 NTP Authentication, MD5
ericsson:
...
ntp_config:
...
authentication: md5
...
To enable authentication between the controllers in CEE and the upstream NTP servers, configure the following:
- group key
- group password
Configure for the upstream NTP servers, and for the controllers in CEE. The group key is a decimal number from 1 to 65534, inclusive. The group password consists of a printable ASCII string, less than or equal to 16 characters.
Example 41 Group Key and Password
ericsson:
...
ntp_config:
...
authentication_upstream_group_key: 1
authentication_upstream_group_password: upstream_group_password
authentication_ericsson_group_key: 10
authentication_ericsson_group_password: ericsson_password
...
- Note:
- Enabling the NTP authentication requires the support and configuration of the upstream NTP servers.
2.8 Legal Text Presented at Logon
There are predefined messages in the config.yaml template that are shown at logon. These can be changed if needed.
If some specific legal text is to be displayed before logon attempts, update the predefined text in the section legaltext:
Example 41 Predefined Legal Text
ericsson:
...
legaltext:
local: "Attention! Unauthorized local access is strictly prohibited!\n"
remote: "\nAttention! Unauthorized remote access is strictly ⇒
prohibited!\n\n"
...
Example 42 Predefined Legal Text
ericsson:
...
legaltext:
local: "Attention! Unauthorized local access is strictly prohibited!\n"
remote: "\nAttention! Unauthorized remote access is strictly prohibited!\n\n"
...
Legal text has two items: local and remote:
- local is used for local logons, for example: serial console.
- remote is used for remote logons, for example: SSH.
Text can be formatted using normal C-style (\t for tab, \n for new line for example).
2.9 Storage
The storage section must be edited with site-specific information.
2.9.1 ScaleIO Configuration
ScaleIO block storage is configured in the scaleio storage subsection in config.yaml. ScaleIO can be configured to function in managed or unmanaged mode. In managed mode, a ScaleIO cluster is configured in config.yaml to be deployed during installation. In case of unmanaged mode, CEE uses an already deployed external ScaleIO cluster, and does not manage it. For more information on the ScaleIO feature and the configurable parameters, refer to the EMC ScaleIO Version 2.0.x User Guide. ScaleIO can be configured using the scaleio section . To enable ScaleIO, the cee_managed key must be set to true (managed ScaleIO) or client (unmanaged ScaleIO).
- Note:
- In case of unmanaged ScaleIO, the parameters must be aligned to the configuration of the already deployed ScaleIO cluster to be used. Additionally, the ScaleIO networks defined in config.yaml must be defined in the external ScaleIO cluster, see Section 2.6.2.
Example 43 Managed ScaleIO Configuration Parameters
ericsson:
storage:
scaleio:
cee_managed: true
protection_domains:
- name: <PROTECTION_DOMAIN_NAME_1>
pools:
- name: <STORAGE_POOL_NAME_1>
zeropadding: <enabled|disabled>
types:
- name: <VOLUME_TYPE>
provisioning_type: <thick|thin>
frontend_networks:['<FRONTEND_NETWORK_1>','<FRONTEND_NETWORK_2>']
backend_networks:['<BACKEND_NETWORK_1>','<BACKEND_NETWORK_2>']
password: <SCALEIO_PASSWORD>
gateway_admin_password: '<SCALEIO_GATEWAY_ADMIN_PASSWORD>'
gateway_port: 4443
gateway_user: <cinder_username>
users:
- name: '<cinder_username>'
pwd: "<cinder_password>"
role: 'FrontendConfigure'
- name: '<username_N>'
pwd: '<password_N>'
role: '<Administrator|Security|BackEndConfigure|FrontEndConfigure|Monitor|Configure>'
Example 43 Managed ScaleIO Configuration Parameters
ericsson:
storage:
scaleio:
cee_managed: true
protection_domains:
- name: <PROTECTION_DOMAIN_NAME_1>
pools:
- name: <STORAGE_POOL_NAME_1>
zeropadding: <enabled|disabled>
types:
- name: <VOLUME_TYPE>
provisioning_type: <thick|thin>
frontend_networks:['<FRONTEND_NETWORK_1>','<FRONTEND_NETWORK_2>']
backend_networks:['<BACKEND_NETWORK_1>','<BACKEND_NETWORK_2>']
password: <SCALEIO_PASSWORD>
gateway_admin_password: '<SCALEIO_GATEWAY_ADMIN_PASSWORD>'
gateway_port: 4443
gateway_user: '<cinder_username>'
users:
- name: '<cinder_username>'
pwd: '<cinder_password>'
role: 'FrontendConfigure'
- name: '<username_N>'
pwd: '<password_N>'
role: '<Administrator|Security|BackEndConfigure|FrontEndConfigure|⇒
Monitor|Configure>'
Example 44 Unmanaged ScaleIO Configuration Parameters
ericsson:
storage:
scaleio:
cee_managed: client
protection_domains:
- name: <PROTECTION_DOMAIN_NAME_1>
pools:
- name: <STORAGE_POOL_NAME_1>
zeropadding: <enabled|disabled>
types:
- name: <VOLUME_TYPE>
provisioning_type: <thick|thin>
gateway_ip: '<SCALEIO_GATEWAY_IP_ADDRESS>'
gateway_port: <SCALEIO_GATEWAY_PORT>
gateway_user: '<cinder_username>'
users:
- name: '<cinder_username>'
pwd: '<cinder_password>'
role: 'FrontendConfigure'
Example 44 Unmanaged ScaleIO Configuration Parameters
ericsson:
storage:
scaleio:
cee_managed: client
protection_domains:
- name: <PROTECTION_DOMAIN_NAME_1>
pools:
- name: <STORAGE_POOL_NAME_1>
zeropadding: <enabled|disabled>
types:
- name: <VOLUME_TYPE>
provisioning_type: <thick|thin>
gateway_ip: '<SCALEIO_GATEWAY_IP_ADDRESS>'
gateway_port: <SCALEIO_GATEWAY_PORT>
gateway_user: '<cinder_username>'
users:
- name: '<cinder_username>'
pwd: '<cinder_password>'
role: 'FrontendConfigure'
The following parameters can be configured for ScaleIO:
cee_managed
- true: enable ScaleIO in managed mode to configure and deploy a ScaleIO cluster in CEE as storage back end.
- client: enable ScaleIO in unmanaged mode to connect CEE to an already deployed external ScaleIO cluster.
- false: disable ScaleIO.
protection_domains
This is a list of protection domains, where each listed element is a dictionary containing the name and pools parameters:
name is the name of the protection domain. pools is a list of the storage pools in the protection domain, in the form of dictionaries containing the following parameters:
- name is the name of the storage pool.
- zeropadding enables or disables the zero padding policy. The accepted parameters are enabled and disabled.
- types is a list of dictionaries
containing the volume types defined for this pool. The dictionaries
must consist of the following parameters:
- name is the volume type name. Unique volume type names must be defined for each protection domain.
- provisioning_type is the provisioning type of the volume type. The supported values are thick and thin.
frontend_networks
List of the mos_name of the ScaleIO frontend networks. This parameter only applies to managed ScaleIO. For more information, see Section 2.6.
backend_networks
List of the mos_name of the ScaleIO back-end networks. This parameter only applies to managed ScaleIO. For more information, see Section 2.6.
password
password is the password for the MDM admin user. This parameter only applies to managed ScaleIO.
gateway_admin_password
gateway_admin_password is the password for the gateway admin user, in quotes. This parameter only applies to managed ScaleIO.
gateway_ip
The gateway IP address of the ScaleIO cluster. This parameter only applies to unmanaged ScaleIO.
gateway_port
The TCP port that the gateway exposes to the REST API interface. For managed ScaleIO, the value must be 4443.
gateway_user
The username to the gateway REST API interface. The user must be defined under the users key with FrontEndConfigure role.
users
The ScaleIO user accounts, in the form of dictionaries containing the following parameters:
- name is the username.
- pwd is the password of the user.
- role is the user role. The
following user roles can be defined: Administrator, Security, BackEndConfigure, FrontEndConfigure, Monitor, Configure.
- Note:
- In unmanaged mode, only one user is to be defined, with FrontEndConfigure role, which must be the same user that was created in the ScaleIO cluster for this particular CEE domain.
To dedicate a blade to be part of the ScaleIO cluster in managed ScaleIO mode, the role of the blade in the cluster has to be defined in the blade section, see Managed ScaleIO Blade Configuration.
2.9.2 Local Storage (SSD)
fstrim is used on mounted file systems to discard blocks which are not in use by the file system. fstrim can be configured in the following ways:
- Configured using the default Canonical settings
- Configured using low priority settings
- Disabled
For more information on fstrim, see the SSD fstrim Configuration section in the CEE Architecture Description, Reference [6].
The structure of the fstrim section in config.yaml is as follows:
Example 45 Ericsson Modified fstrim Configuration
blade:
...
fstrim:
disabled: <true | false>
type: <default | ericsson>
...disabled
To completely disable the automatic fstrim, set to true. If set to false, fstrim runs automatically once a month.
type
- Note:
- If disabled is set to true, this parameter does not apply.
The following parameters are available:
- ericsson: to run fstrim with lower scheduling class and priority (ionice -c 3 nice -n 19), set to ericsson. In this case, the TRIM is applied in 5 GB chunks in five second intervals.
- default: for the default Canonical best-effort settings (ionice -c 2 -n 2), set to default.
This is an optional parameter. If the type parameter is omitted, the default configuration will apply.
2.9.3 Software RAID Configuration
The swraid Boolean key is used to enable software RAID configuration on a per compute blade basis.
- Note:
- Only RAID 1 is supported, and the compute blades must have
two physical disks to use this feature. Provisioning can take more
time than usual, as RAID 1 is created during this phase.
The write I/O operations on the installed system will be impacted due to the RAID 1 configuration. The disk capacity of the compute blade will be reduced by half, as a result of RAID 1.
The following values are valid:
swraid is an optional parameter. If undefined, RAID is not configured on the compute blade.
Example 46 Software RAID Configuration
ericsson:
...
shelf:
-
id: 0
blade:
-
id: 1
blade_mgmt:
...
swraid: True
...
2.10 Local Disk Partition Sizes
The section localdisks has local disk partition sizes for local disk (for compute hosts) and partition sizes of virtual disk (for vCIC). The sizes are in mebibyte (MiB). The sizes are applied to all partitioning for vCIC (guest OS) and Host OS. The default settings in config.yaml are the minimum requirement and cannot be decreased. On compute nodes, the remaining disk space is allocated to /var/lib/nova (for data that includes local storage and ephemeral disks).
On vCIC nodes, the remaining disk space is allocated to /var/lib/glance and is used for Glance, Swift, and CIC Domain Data Backup.
The partition sizes must be dimensioned according to the site-specific needs. The mysql_size value is not filled in the template, must be added based on the System Dimensioning Guides:
- Note:
- Consider the size of virtual disk available to vCIC.
Example 47 Local Disks
ericsson:
...
storage:
localdisks:
cic:
os_size: 51200
logs_size: 40960
mysql_size: <MYSQL_SIZE_IN_MiB>
mongo_size: 40960
compute:
os_size: 51200
logs_size: 40960
...
- Note:
- Do not define mongo_size in a single server deployment.
2.11 IdAM
IdAM is used for managing the system administrator accounts. The idam: section includes credentials for the IdAM component. It allows setting initial passwords for the predefined accounts needed for CEE to operate.
The ldap section includes credentials of LDAP entities used exclusively by infrastructure applications. The recommendation is to leave these credentials blank to enable the system to use generated passwords.
It is possible to set the initial password of the ceeadm and ceebackup in the users section:
Example 48 Password for the ceeadm Predefined User
ericsson:
...
users:
ceebackup:
idam_tag:
- admin
passwd:' <IDAM.CEEBACKUP.PASSWD>'
ceeadm:
idam_tag:
- none
passwd:' <IDAM.CEEADM.PASSWD>'
...
Passwords must be quoted by using single-quotes and must be compliant with CEE password policy, otherwise the deployment fails. The minimal accepted password length is 12 characters. There is no factory default password.
- Note:
- ceebackup is not applicable to single server deployment.
2.12 LDAP Users
The LDAP section includes credentials used by infrastructure applications, if these credentials are left blank in the config.yaml, the entries from the idam_ldap_*_password section in /etc/openstack_deploy/user_secrets.yml are used.
Example 49 LDAP
ericsson:
idam:
ldap:
basedn: <IDAM.LDAP.BASE>
rootdn: <IDAM.LDAP.ROOTRDN>
rootpw: ''
anonymous_binddn: <IDAM.LDAP.ANONRDN>
anonymous_bindpwd: ''
manager_binddn: <IDAM.LDAP.MNGRRDN>
manager_bindpwd: ''
sync_binddn: <IDAM.LDAP.SYNCRDN>
2.13 Glance Image Service
The Glance API server can be configured to have an optional local image cache. A local image cache stores a copy of image files, essentially enabling multiple API servers to serve the same image file. This increases scalability due to an increased number of endpoints serving an image file.
The Glance image cache is disabled in the configuration file templates.
Enable the local image cache for CEE deployments where there is sufficient disk space available for Glance image cache on local disks. For CEE deployments where the local disk space is limited it is more favorable to disable the function or to reduce the disk space used for the local image cache on the /var/lib/glance disk partition.
Two parameters are available in the storage section of config.yaml to manipulate the Glance image cache function:
- Set enable_glance_image_cache to true to activate the Glance image cache.
- Use image_cache_max_size to define the maximum size of the disk space in bytes used for Glance image cache. The value set in the config.yaml templates for image_cache_max_size is 5368709120 bytes.
Glance can optionally be configured on the storage network. For more information, see Section 2.6.4.
2.14 GRUB Configuration
Credentials for accessing Grub menu entries must be configured in the grub section. The GRUB username and password are mandatory parameters.
Example 50 GRUB Configuration
ericsson:
grub:
grub_username: <SUPER_USERNAME>
grub_password: ''
For successful deployment, the grub_password value must be in single quotes and must be compliant with the CEE password policy. The minimum accepted password length is 12 characters.
- Note:
- There is no default password. The parameter must not be left empty.
2.15 Swift Configuration Options
The swift section in the configuration file template allows to configure Swift to use the back-end storage system, and by this to move the location of the Swift store from the local disks to the back-end storage. Currently, the supported storage back end for Swift is ScaleIO.
- Note:
- The prerequisite to configure Swift on back-end storage is
as follows:
- To use ScaleIO as storage back end: a properly configured ScaleIO block storage, see Section 2.9.1.
If the prerequisite is not fulfilled, the swift_on_backend_storage section is not applicable and will be ignored.
The following configuration options are available:
Example 51 Swift Configuration Options
ericsson:
...
swift:
swift_on_backend_storage:
type: <SWIFT.SWIFT_ON_BACKEND_STORAGE.TYPE>
activation_mode: <SWIFT.SWIFT_ON_BACKEND_STORAGE.MODE>
lun_size: <SWIFT.SWIFT_ON_BACKEND_STORAGE.SIZE>
type
The type of the back-end storage system. To configure Swift to use ScaleIO as storage back end, the type must be set to scaleio.
activation_mode
The supported values are manual and automatic. The value set in the config.yaml templates is manual.
To deploy Swift on ScaleIO manually after installation, refer to the Swift Store on ScaleIO Activation operating instructions.
The automatic activation mode can be used to deploy Swift on back-end storage during installation.
lun_size
lun_size specifies the LUN size of Swift on the storage back end. The value must be given as an integer value followed by the unit (GiB or TiB). The value set in the config.yaml templates is 0GiB in combination with activation_mode set to manual.
If activation_mode is set to automatic, a value different from 0GiB must be used. The unit has to be given in GiB or TiB. The minimum value is 1GiB.
- Note:
- ScaleIO only supports volumes with a granularity of 8 GiBs. As a result, the physical size of the LUN will always be rounded up to the nearest multiple of 8 GiBs, while Cinder is not aware of this rounding and uses the given size. Therefore, it is recommended to set a lun_size which is a multiple of 8 GiBs.
2.16 SDN Integration on HDS
To enable the SDN integration feature of HDS, the sdn section has to be defined in config.yaml. This feature enables the user to deploy CEE with the CSC integrated, without any other extension package. The CSCs running inside CEE vCICs will be used to manage the tenant network and create tunnels on compute blades for tenants network isolation. Software VTEPs are created automatically during CEE deployment. The parameters needed for SDN configuration are as follows:
Example 52 SDN Configuration
sdn:
sdnc_admin_username: <SDNC.ADMIN.USERNAME>
sdnc_admin_password: <SDNC.ADMIN.PASSWORD>
remote_gre_term: <REMOTE.GRE.TERM.IP>
sdnc_admin_username
Username for CSC authentication
sdnc_admin_password
Password for CSC authentication
remote_gre_term
The DC-GW loopback IP(s). If there are multiple IP addresses, they are to be added as a list, for example: [' 10.33.215.30', ' 10.33.215.31']
2.17 CM-HA
The cmha section of config.yaml is used to configure the Continuous Monitoring High Availability (CM-HA) service, and includes the following parameters:
- Note:
- The parameters below are optional. If these parameters are not included in config.yaml, the default values apply.
fence_compute_before_evacuation
If fence_compute_before_evacuation is true, CM-HA is to fence down the compute host before evacuating the VMs. This function is to prevent VM duplication in case of a partial compute failure. Default value: true
try_to_recover_compute_after_evacuation
If try_to_recover_compute_after_evacuation is true, CM-HA attempts to power on the compute host after finishing the evacuation of the VMs. This function can help recover the failed compute. Default value: true
- Note:
- In the HDS with SDN configuration template, the default value for fence_compute_before_evacuation and try_to_recover_compute_after_evacuation is false.
In case of non-Ericsson hardware, the subrack_ctrl_sp network has to be configured with start, end, and mos_name parameters for vCIC access, see Section 2.6.
2.18 Fuel Plugins
The fuel-plugins section of config.yaml is used for the installation and configuration of Fuel plugins. For more information on Fuel plugins, including the plugin name, configuration attributes, and the list of mandatory and optional Fuel plugins, refer to the Fuel Plugin Configuration Guide.
The fuel-plugins section includes the following parameters:
Example 53 Fuel Plugin Configuration
ericsson:
...
fuel-plugins:
-
name: <PLUGIN-NAME>
config_attributes:
<ATTRIBUTE1>: <VALUE1>
<ATTRIBUTE2>: <VALUE2>
-
name: <PLUGIN-NAME>
...
name
The name of the Fuel plugin to be installed.
- Note:
- The variable <PLUGIN-NAME> must match the name mentioned in the metadata.yaml file of the Fuel plugin.
config_attributes (optional)
Any configuration attributes needed for the plugin are added in the config_attributes section using the below structure:
...
config_attributes:
<ATTRIBUTE1>: <VALUE1>
<ATTRIBUTE2>: <VALUE2>
...
If no configuration attributes are specified, the default Fuel plugin values are automatically set.
2.19 Change of Linux I/O Scheduler
The user must select the I/O scheduler for the compute hosts. This changes the strategy used for scheduling I/O requests. The parameter is global and applies to all compute hosts.
Example 54 Selecting IO Scheduler Options
ericsson: ... timezone: Etc/UTC compute_io_scheduler: <IO.Scheduler> ... neutron: ...
The following values can be configured for compute_io_scheduler:
- deadline starts the Deadline scheduler that caps the maximum latency per request, and maintains high disk throughput.
- cfq starts the Completely Fair Queuing scheduler that is used for maintaining system-wide fairness of I/O bandwidth.
- noop starts the simple NOOP scheduler. NOOP is used for memory-backed block devices such as RAM disks, and non-rotational media such as flash.
2.20 License Management Configuration
- Note:
- The ericsson_sheriff Fuel plugin must be enabled in the config.yaml for license management. Refer to the Fuel Plugin Configuration Guide.
The Sheriff license management can be configured using the license key in the config.yaml. The following configuration options are available:
Example 55 Example License Management Configuration
ericsson:
...
license:
nels_server_host: <NELS.SERVER.IP>
nels_server_port: <NELS.SERVER.PORT>
nels_server_trusted_hostname: <NELS.TRUSTED.HOSTNAME>
tls_trusted_ca_certificate: <TRUSTED.CA.CERT>
tls_nels_client_private_key: <NELS.CLIENT.PRIVATE.KEY>
tls_nels_client_certificate: <NELS.CLIENT.CERT>
openssl:
ciphersuites: <CIPHERSUITES>
protocols: <SSL.PROTOCOL>
NeLS Server Configuration
The NeLS server can be configured using the following parameters:
- nels_server_host: The hostname or IP of the NeLS server.
- nels_server_port: The port to be used on the NeLS server.
- nels_server_trusted_hostname: The trusted hostname of the NeLS server.
Certificate Configuration
- Note:
- The files needed for certificate configuration must be copied to /mnt/cee_config/ before CEE deployment.
The certificates can be configured using the following keys:
- tls_trusted_ca_certificate: The certificate for authentication of the TLS connection.
- tls_nels_client_private_key: The file containing the private key for the TLS connection.
- tls_nels_client_certificate: The client certificate for the NeLS authentication.
SSL Configuration
The SSL encryption can be configured using the openssl key, which has the following subkeys:
- ciphersuites: The string containing the list of allowed OpenSSL cipher suites.
- protocols: The protocols
to be used for TLS.
- Note:
- In the current release, only the TLSv1.2 protocol is possible to be used.
3 Advanced Parameter Settings
This section contains the advanced configuration options of config.yaml and explains how to change the default values used in the templates.
- Note:
- Not all possible combinations have been formally verified by CEE Integration and Verification.
3.1 Advanced CPU Allocation
To reserve CPUs on a specific compute host, the reservedCPUs section of the corresponding blade must be filled in with information on the reservation. Reservation for a server consists of a list of CPU reservations. Each item in the list represents the CPU reservation for a specific system component (owner). The reservation for a system component is defined by a mapping (also called hash or dictionary in programming languages) containing the keys owner, count, and cpus.
The owner key is mandatory. It specifies the component for whom the reservation is intended. Supported owners are vm, ovs, vcic, and vfuel.
- Note:
- It is possible to reserve CPUs for not supported owners. The CPUs reserved for such owners remain idle since they are added to the list of isolated CPUs and none of the supported system components use them.
Either the count or the cpus key must be defined, but not both. Deviations from this rule are explained later.
The value of the count key is either the string auto or an integer. When the value auto is used, the CEE installer determines how many CPUs to reserve for the given owner and which ones. If the value is an integer, it defines the number of CPU cores to reserve. Due to hyperthreading, one core corresponds to two CPUs. When a CPU core is reserved for an owner, both CPUs on that core are dedicated to that owner. The System Dimensioning Guides provide information about the relation between CPUs and cores for supported hardware models.
Refer to the following documents:
The value of the cpus key is a list of CPU IDs or ID ranges. The ranges are inclusive. By using the cpus key, the cloud administrator can directly control the allocation of CPUs to owners. Although it is possible to reserve CPUs by mixing allocations that use the count and the cpus keys for different CPU owners (ovs, vm, vfuel, vcic), this practice is not recommended, because the configuration validation before deployment may fail.
- Note:
- Reserving CPU 0 for any owner is not recommended. The CPUs reserved for any owner in config.yaml are added to the kernel list of isolated CPUs, ensuring that the kernel does not schedule common host OS processes to run on the isolated CPUs. The kernel uses CPU 0 during boot, and does not enable any other CPUs until late in the boot process. The isolcpus boot parameter of the kernel does not move already started processes (such as driver or worker threads) off CPU 0, only ensures that processes started subsequently will not use the isolated CPUs by default. Therefore, it is possible that processes keep using CPU 0 even if it is listed in the isolcpus kernel parameter.
3.1.1 Automatic CPU Allocation Rules
The CEE installer allocates CPU resources using the rules described here when only the count key is used in CPU reservations.
- Note:
- These rules are not applicable when the CPUs are reserved manually using the cpus key.
Two CPU cores are assigned to the host OS (that is, left as non-isolated) when the reservation count: auto is used for the owner: vm. If the number of CPU cores to be reserved for VMs is explicitly set, or no CPU reservation is made for VMs, then all remaining CPU cores are used by the host OS. It is a configuration error if there are no CPU cores left for the host OS.
Six CPU cores are reserved for vCIC, and one CPU core is reserved for vFuel, if count: auto is used. The auto configuration is only applicable to small regions, for proper dimensioning, refer to the Multi-Server System Dimensioning Guide, CEE 6. The installer attempts to allocate all cores from the same NUMA node, starting with NUMA 0. If unsuccessful, an attempt is made to split the cores evenly across all NUMA nodes. If the cores cannot be evenly split across the NUMA nodes, the installer will allocate as many cores as possible from NUMA 0, then from NUMA 1. If this is not possible, it will follow the same logic starting from NUMA 1. If the installer cannot find enough available cores to satisfy the request, CEE installation fails.
CEE deployment fails if the CPU allocation succeeds, but no sufficient memory is available in the NUMA node. In this case, the cpus key must be used to manually distribute the cores over the available NUMA nodes, as memory is allocated proportionally to the amount of reserved CPU per NUMA node. For example: in case of more than one NUMA nodes and 64 GiB RAM: if the 30 GiB is reserved for the vCIC, and all cores fit in a single NUMA node, an insufficient amount of memory is available in that NUMA node for the host OS. As a result, CEE deployment fails. In this case, the user can manually split the required number of cores equally across the two NUMA nodes, so 15×1 GiB hugepages will be allocated from each node for the vCIC.
The first CPU core on each NUMA node is assigned to the host OS (left non-isolated) if the number of required host OS cores are at least equal to the number of NUMA nodes. Then one CPU core is reserved for OVS PMD threads on each NUMA node. On NUMA node 0 (and NUMA node 1, if it exists), the first one or two available cores are reserved for OVS PMD threads, depending on the css_mode configuration (see Section 3.1.2). After that, the CPUs are reserved for vCIC, vFuel, and tenant VMs, in this order. For more information on CSS auto configuration options, see Section 3.1.2.1.
The first CPU used by the host OS is also assigned to the OVS control process unless it is explicitly defined. See Section 3.1.2 for details.
3.1.2 Allocating CPUs for CSS (OVS)
- Note:
- After CEE deployment, the CSS CPU allocation can only be changed during server replacement. For details, refer to the Runtime Configuration Guide.
OVS requires CPUs for different purposes. Some of the CPUs are used for poll-mode driver (PMD) threads. The PMD threads continuously poll the physical and virtual NICs to check if there is new data. It is crucial that no other tasks are scheduled on the CPUs assigned to OVS PMD threads for performance reasons. In addition, one CPU must be specified for the OVS control process. This process does not have special requirements on its CPU. It can share one of the non-isolated CPUs with the other host OS processes. CPUs reserved for the owner ovs in config.yaml are used for PMD threads
- Note:
- At least one CPU must be reserved for PMD threads on each NUMA node. Failure to fulfill this constraint leads to system malfunction.
Refer to the System Dimensioning Guide for the details on CPU allocation for CSS.
There are two main options for allocating CPUs for CSS (OVS), using the mandatory key css_mode:
- Automatic configuration, using one of the following modes: normal-perf, high-perf, ultra-perf. For more information about using the automatic configuration, see Section 3.1.2.1.
- Custom configuration, using the custom mode. If this mode is selected, the count or the cpus key can be used to allocate a number of cores, or specific cores, respectively. For more information about using the custom configuration, see Section 3.1.2.2.
css_mode is a mandatory key if CPUs are allocated using count or cpus (custom configuration).
The appropriate CPU reservation has to be set for each blade in the blade section, depending on whether it hosts vCIC or vFuel. An example is:
ericsson:
...
shelf:
...
blade:
-
id: 1
blade_mgmt:
...
nic_assignment: *DELL_630_nic_assignment
reservedHugepages: *DELL_630_reservedHugepages
reservedCPUs: *OVS_single_thread_DELL_630_reservedCPUs
ericsson:
...
shelf:
...
blade:
-
id: 1
blade_mgmt:
...
nic_assignment: *DELL_630_nic_assignment
reservedHugepages: *DELL_630_reservedHugepages
reservedCPUs: *OVS_single_thread_DELL_⇒
630_reservedCPUs
3.1.2.1 Automatic CPU Allocation for CSS
- Note:
- CSS version R10A (Fuel plugin version 1.0-1.0.13-1) or later is required for normal-perf, high-perf, and ultra-perf configuration. For automatic CPU allocation using an earlier CSS version, use the count: auto configuration without defining css_mode.
Cores can be automatically reserved for CSS by setting the css_mode key to either of the following values:
- normal-perf: One core is allocated for CSS per NUMA node (1 physical CPU + 1 hyper-thread CPU).
- high-perf: Two cores are allocated for CSS per NUMA node (2 physical CPUs).
- ultra-perf: Two cores are
allocated for CSS per NUMA node (2 physical CPUs + 1 hyper-thread
CPU).
- Note:
- The ultra-perf configuration is an experimental feature with limited verification. Refer to the CSS User Guide, Reference [9].
For details about the exact CPU (physical and hyper-thread sibling) reservation methods used for normal, high and ultra performance allocations and for the performance implications, refer to the CSS User Guide, Reference [9].
Compute servers with only one NUMA node (for example, BSP deployment) provide decreased CSS performance with the automatic allocation method compared to platforms with two (for example: Dell, HDS deployment) or more NUMA nodes.
- Note:
- If the css_mode key is not defined in config.yaml, normal-perf is configured by default.
In case of automatic CPU allocation, count: auto must be used.
Example 56 Example Auto Core Allocation for CSS
ericsson:
...
reservedCPUs:
- &CSS_auto_reservedCPUs
- owner: vm
count: auto
- owner: ovs
count: auto
css_mode: high-perf3.1.2.2 Custom CPU Allocation for CSS
In case of custom CPU allocation, the count or the cpus key must be used to allocate cores. If the count key is used, the value must be an integer, not auto. The css_mode key must be defined with the value custom.
- Note:
- Using custom CPU allocation when css_mode is not defined as custom results in installation failure.
If the count key is used to specify the allocated cores for reserving the OVS PMD CPUs, at least one CPU core per NUMA node must be allocated to OVS PMD threads. For example, at least two cores are required on Dell and HDS compute servers, while only one is required on BSP. In this case, both the physical CPUs and the hyper-threading siblings of the respective cores are allocated for the OVS PMD threads, and added to the isolcpus and nohz_full boot parameter lists of the kernel. Any additional cores are allocated sequentially from the available cores, starting with NUMA node 0 and then continuing with NUMA node 1, if necessary.
Example 57 Example Custom CPU Allocation for CSS
ericsson:
...
reservedCPUs:
- &CSS_custom_3_reservedCPUs
- owner: vm
count: auto
- owner: ovs
css_mode: custom
count: 3In Example 57, three cores are allocated for CSS. An even more precise allocation option is to specify the exact CPUs to be allocated using the cpus key, with the value being a list of CPU IDs or ID ranges.
To allocate a single CPU per core for OVS, new definitions have to be created under reservedCPUs for each compute host and deployment scenario (with or without vCIC and vFuel). An example is:
ericsson:
...
reservedCPUs:
- &CSS_single_thread_DELL_630_reservedCPUs
- owner: vm
cpus: 1,3,5-22,25,27,29-46
- owner: ovs
css_mode: custom
cpus: 2,23
cpus_nonpmd: 0
- owner: idle
cpus: 26,47
notick: true
For more information on the CSS CPU reservation methods, refer to the CSS User Guide, Reference [9].
Of the two CPUs in a core, the lower numbered must be reserved for OVS.
The hyper-thread siblings of OVS PMD CPUs must be allocated to the owner idle and the notick allocation parameter is set to the value true.
This results in the following:
- These CPUs are listed in the kernel isolcpus boot parameter list, ensuring that the process scheduler does not assign any processes to these CPUs apart from the ones allocated for OVS OMD threads (owner: ovs).
- These CPUs are listed in the kernel nohz_full boot parameter list, ensuring that the kernel does not generate scheduling clock interrupts on these CPUs apart from the ones allocated for OVS OMD threads.
By default, the OVS control process uses the first CPU allocated for the host OS. This can be overruled by defining the cpus_nonpmd key. The recommended value is a single CPU ID. Only non-isolated CPUs are allowed. That is, CPUs reserved for other purposes (including OVS PMD threads) are not allowed. Make sure that the constraints listed above are fulfilled.
- Note:
- Although it is possible to define a set of CPUs for the OVS control process, it is currently not recommended to assign more than one CPU.
OVS is configured to use DPDK only if CPUs and huge pages are both reserved for the owner ovs. OVS is configured to run without DPDK if there are no reservations. It is a configuration error if only one of CPUs or huge pages are reserved. VMs must also use hugepages to be able to communicate over OVS/DPDK. Therefore, it is mandatory to reserve 1 GiB huge pages for VMs if OVS/DPDK is used.
- Note:
- It is not possible to configure a CEE region without DPDK acceleration for traffic network (provided by the corresponding OVS bridges).
3.1.3 Resource Allocation for vCIC
The CPU allocation for vCIC (owner: vcic) supports the boolean key isolated to control if dedicated CPUs have to be allocated for the vCIC VM. Its value is either the default true or false.
If isolated: true is configured or the key is omitted, the vCIC uses dedicated physical CPUs, and the virtual CPUs of the vCIC VM are mapped one-to-one to the reserved physical CPUs. In this case, the hugepages are taken from the same NUMA nodes to which the physical CPUs belong. In case cores are allocated to the vCIC from two NUMA nodes, the huge pages are allocated in proportion to the number of CPUs on each NUMA node.
If isolated: false is configured, no physical CPUs are reserved for the vCIC. Instead, it shares the non-isolated physical CPUs, or a subset of them, with the host OS processes. If the cpus key is defined, it must be a subset of the non-isolated CPUs and the vCIC only uses these physical CPUs. If cpus is not defined, the vCIC uses all non-isolated CPUs. If the count key is defined, it is used to calculate the number of vCPUs in the vCIC. . The number of vCPUs to use is calculated as count×HTs/core. The resulting number of vCPUs cannot be higher than the number of physical CPUs on which the vCIC is allowed to run.
Example 58 Use non-isolated CPUs for a vCIC with 4 vCPUs
ericsson:
...
reservedCPUs:
- owner: vcic
count: 2
isolated: false
...- Note:
- Using the isolated: false CPU allocation is not recommended on multi-server systems.
In case isolated: false is used for CPU configuration, then in the memory allocation for the vcic owner, the memnode key can be used to specify the NUMA node ID on the physical host. If specified, then the memory of the VM is allocated from the given NUMA node. If the memnode key is not defined, the VM memory is allocated from NUMA node 0.
Example 59 Reserve 30 GiB RAM for a vCIC using physical memory on NUMA node 1
ericsson:
...
reservedCPUs:
- owner: vcic
count: 2
isolated: false
...
reservedHugepages:
- owner: vcic
size: 1GB
count: 30
memnode: 1
...
If isolated: false is not used for CPU reservation, the memory will be allocated from the NUMA nodes proportionally to the number of CPUs in the NUMA node.
3.1.4 CPU Allocation for Single Server Deployment
The following example shows the recommended CPU allocation for a Single Server deployment:
Example 60 Allocating vCPUs Reserved for VMs
ericsson:
...
reservedCPUs:
- owner: vm
cpus: 6,30,8,32,10,34,7,31,9,33,11,35,13,37,15,39,17,41,19,43,21,45
- owner: ovs
count: auto
cpus_nonpmd: 1
- owner: vcic
count: 2
isolated: false
...
This example illustrates some of the concepts discussed before:
- CPUs are assigned manually using the cpus key to reserve specific CPUs.
- As a consequence, this allocation is suitable for a specific server and processor model because the NUMA topology and the numbering of CPUs vary among systems. This example assumes a Dell R630 server equipped with 2 Intel Xeon E5-2680 v3 processors.
- No dedicated CPUs are reserved for the vCIC, it uses any of the non-isolated CPUs.
For more information on single server CPU allocation, refer to Single Server System Dimensioning Guide, CEE 6.
3.2 NUMA Balancing
The automatic NUMA balancing kernel feature can be disabled on the compute blades, both globally and on a per blade basis:
Example 61 Example NUMA Balancing Configuration
ericsson:
global_numa_balancing: false
shelf:
-
id: 0
...
blade:
...
-
id: 2
numa_balancing: trueglobal_numa_balancing
The global configuration key for NUMA balancing is global_numa_balancing, which takes a boolean value. If set to true, the automatic NUMA balancing is enabled in the whole region. If set to false, NUMA balancing is disabled in the region. The default value is true.
This configuration can be overridden on individual blades using the numa_balancing blade key.
numa_balancing
The shelf/blade/numa_balancing key can be used to override the global_numa_balancing or the default configuration on a per blade basis. If set to true, the NUMA balancing kernel feature is enabled on the respective compute blade. If set to false, NUMA balancing is disabled on the blade.
If neither global_numa_balancing nor numa_balancing is configured, all compute blades will be installed with the NUMA balancing kernel feature enabled.
3.3 DPDK Physical Interface Driver
The DPDK physical interface driver can be configured on each compute blade as follows:
Example 62 Example DPDK Physical Interface Driver Configuration
ericsson:
global_ovs_dpdk_io_driver: vfio-pci
shelf:
-
id: 0
...
blade:
...
-
id: 2
ovs_dpdk_io_driver: uio_pci_genericThe supported DPDK physical interface driver on each respective platform is as follows:
- Note:
- The OVS DPDK physical interface must be defined, either globally or for each individual compute blade.
global_ovs_dpdk_io_driver
The global_ovs_dpdk_io_driver key is used to set the DPDK physical interface driver in the whole region. The supported values are vfio-pci and uio_pci_generic. The global configuration can be overridden on a per blade basis using the ovs_dpdk_io_driver key.
ovs_dpdk_io_driver
The shelf/blade/ovs_dpdk_io_driver key is used to set the DPDK physical interface driver of a specific blade. The supported values are vfio-pci and uio_pci_generic. This key overrides the parameter set in global_ovs_dpdk_io_driver for the blade.
3.4 Kernel Parameter Settings
In order to fine-tune the system performance, the following parameters can be configured:
vm_stat_interval / global_vm_stat_interval
The interval of the memory statistic updates can be configured in the whole region using the global_vm_stat_interval key. The value is to be given in seconds.
The vm_stat_interval blade configuration key can be used to configure the interval on a per blade basis. This key overrides the global setting.
Both keys are optional. If neither the global nor the blade key is defined, the default value (120 seconds) becomes active for each blade.
Example 63 Example vm_stat_interval Configuration
ericsson:
global_vm_stat_interval: 110
shelf:
-
id: 0
blade:
-
id: 2
vm_stat_interval: 115
kernel_nmi_watchdog / kernel_nmi_watchdog
Non Maskable Interrupts (NMI) can be enabled or disabled in the whole region using the global_kernel_nmi_watchdog key. Correct values are 0 (disabled) and 1 (enabled).
The kernel_nmi_watchdog blade configuration key can be used to configure the NMI on a per blade basis. This key overrides the global setting.
Both keys are optional. If neither the global nor the blade key is defined, the default value (0) becomes active for each blade.
Example 64 Example kernel_nmi_watchdog Configuration
ericsson:
global_kernel_nmi_watchdog: 1
shelf:
-
id: 0
blade:
-
id: 2
kernel_nmi_watchdog: 03.5 Increasing Virtio Queue Size
- Note:
- This feature requires the ericsson_performance Fuel plugin to be configured. For more information, refer to the Fuel Plugin Configuration Guide.
An updated QEMU package with virtio_queue_size increased to 1024 descriptors can be optionally enabled on a per blade basis using the increased_virtio_queue key:
Example 65 Example increased_virtio_queue Configuration
ericsson:
shelf:
-
id: 0
blade:
-
id: 2
increased_virtio_queue: True
This configuration is only applicable to blades with the role compute.
If the increased_virtio_queue key is set to True, the QEMU package will be updated on the blade. If undefined or set to False, the standard QEMU package will be installed.
3.6 NIC Information
The section nic_assignments defines role-based PCI addresses for all NICs in the system, for the control, traffic and storage networks. If the relevant hardware is not listed in nic_assignments in the relevant template, add or modify the relevant element in the list.
The PCI addresses must be defined in the following format: XXXX:YY:ZZ.W
where:
XXXX = domain, must always be 0000
YY = bus
ZZ
= slot
W = function
Anchors are used to label each assignment in nic_assignments. See Section 1.5.1 for the use of anchors and aliases.
- Note:
- Every network role (control, data, storage) must be configured for a NIC assignment. Failure to do so results in deployment failure.
Example 66 Example NIC Assignment
ericsson:
nic_assignments:
- &DELL_630_nic_assignment
control0: "0000:01:00.0"
control1: "0000:01:00.1"
data0: "0000:81:00.0"
data1: "0000:04:00.0"
storage0: "0000:81:00.1"
storage1: "0000:04:00.1"
- &DELL_620_nic_assignment
control0: "0000:01:00.0"
control1: "0000:01:00.1"
data0: "0000:42:00.0"
data1: "0000:04:00.0"
storage0: "0000:42:00.1"
storage1: "0000:04:00.1"3.7 SR-IOV
- Note:
- The SR-IOV feature is configurable on Dell multi-server hardware platform, and on HDS platform with additional NICs available for SR-IOV.
To enable SR-IOV traffic network support, the feature has to be configured in config.yaml in the following places:
- On a per blade basis, using the sriov key, see Section 3.7.1.
- In the global configuration, using the sriov_segmentation_type key, see Section 3.7.2
- In case of CEE-managed switch configuration (Extreme), in the switch cabling scheme configuration template, see Section 3.7.3
3.7.1 SR-IOV Blade Configuration
- Note:
- SR-IOV can only be enabled on compute nodes.
The sriov key is to be configured individually for each blade that will have the SR-IOV feature enabled. The key is not to be configured for blades not using SR-IOV. To define SR-IOV on a specific blade, include the sriov key with the number of virtual functions and devices properties in the blade section. You can reference the devices with aliases that point to pre-defined anchors in sriov_configs at the beginning of the configuration file.
Additionally, the configuration of an arbitrary provider physical network for each SR-IOV Physical Function (PF) is supported. This makes the PF resource management significantly more dynamic.
More anchors can be added in sriov_configs if the used hardware configuration is different from the provided ones. See also Section 1.5.1 about YAML syntax.
See the configuration example below:
Example 67 8 VFs with 2 SR-IOV Devices in Blade 2, All PFs Connected to "physnet1"
ericsson:
...
sriov_configs:
- &DELL_620_sriov_info
- pci_address: "0000:41:00.0"
bandwidth: 10000000
physical_network: "physnet1"
- pci_address: "0000:41:00.1"
bandwidth: 10000000
physical_network: "physnet1"
- &DELL_630_OEM_sriov_info
- pci_address: "0000:83:00.0"
bandwidth: 10000000
physical_network: "physnet1"
- pci_address: "0000:83:00.1"
bandwidth: 10000000
physical_network: "physnet1"
- &DELL_630_sriov_info
- pci_address: "0000:84:00.0"
bandwidth: 10000000
physical_network: "physnet1"
- pci_address: "0000:84:00.1"
bandwidth: 10000000
physical_network: "physnet1"
...
shelf
-
blade:
-
id: 2
sriov:
devices: *DELL_630_sriov_info
vf: 8
...
ericsson/sriov_configs
The dictionaries containing the PCI addresses of SR-IOV NICs (PFs) have to be defined in sriov_configs. The N-th SR-IOV PF on a blade is the N-th listed item in the dictionary for the blade. Each listed item must contain the pci_address and physical_network parameters.
- pci_address identifies the
network interfaces that must be used for SR-IOV purpose on the compute
node. Enter in format "DDDD:BB:SS.F" key-value pairs.
D=domain (always 0000), B=Bus, S=Slot, F=Function. The double quoting is mandatory for the value of pci_address. This is a mandatory parameter if sriov is defined. - bandwidth is the bandwidth of the traffic Ethernet interfaces as specified by the hardware NIC vendor, in kilobit/s. This parameter is not mandatory.
- physical_network is the name of the physical network assigned to the respective device. This is a mandatory parameter if sriov is defined. The name of the physical network can contain alphanumeric characters, underscores ("_"), and hyphens ("-"). The same physical_network name can be used for different SR-IOV PFs.
ericsson/shelf/blade/sriov
- devices is a list of dictionaries containing the PCI addresses of SR-IOV NICs (PFs). The list of devices cannot contain more than two devices.
- vf specifies the number of
Virtual Functions (VFs) on compute nodes assigned to each PF (NIC).
The maximum value is 16. This is a mandatory parameter if sriov is defined.
- Note:
- It is highly recommended to define the same number of VFs for each blade on which SR-IOV is configured. Asymmetric vf configuration can result in SR-IOV VMs not being migrated or evacuated to other compute hosts.
3.7.2 SR-IOV Global Configuration
The global sriov_segmentation_type key has to be set if the SR-IOV blade configuration is enabled on one or more blades, see Section 3.7.1. This key is used to enable type(s) of network segmentation in a CEE region. The following network segmentation options are available:
- vlan: enables VLAN segmentation in the CEE region, see Example 68.
- flat: enables flat networking in the CEE region, see Example 69.
- both vlan and flat: enables both VLAN segmentation and flat networking in the CEE region. see Example 70.
Example 68 SR-IOV with VLAN Segmentation Enabled in the Region
ericsson:
...
sriov_segmentation_type:
- vlan
neutron:
...
neutron_config_yaml_file: neutron_ericsson_extreme.yaml
...
hw_switches:
initial_setup: extreme
switching_scheme_yaml_file: 2_x670v_switch.yaml
cabling_scheme_yaml_file: 2_x670v_dell.yamlExample 69 SR-IOV with Flat Networking Enabled in the Region
ericsson:
...
sriov_segmentation_type:
- flat
neutron:
...
neutron_config_yaml_file: neutron_ericsson_user_spec.yaml
...
hw_switches:
initial_setup: NoneExample 70 SR-IOV with Both Flat Networking and VLAN Segmentation Enabled in the Region
ericsson:
...
sriov_segmentation_type:
- flat
- vlan
neutron:
...
neutron_config_yaml_file: neutron_ericsson_user_spec.yaml
...
hw_switches:
initial_setup: None
3.7.3 SR-IOV Cabling Scheme Configuration
In case of CEE-managed switch configuration, the cabling scheme YAML file must be updated according to the allocation of SR-IOV ports in the traffic switch. The SR-IOV ports have the value usage: sriov.
Example 71 SR-IOV Cabling Scheme Configuration
cabling_scheme:
shelves:
- blades:
- blade_id: 1
network interfaces:
- {nic_id: 1, switch_id: 1, switch_port: 1, usage: data}
- {nic_id: 2, switch_id: 2, switch_port: 1, usage: data}
- {nic_id: 3, switch_id: 1, switch_port: 2, usage: storage}
- {nic_id: 4, switch_id: 2, switch_port: 2, usage: storage}
- {nic_id: 5, switch_id: 1, switch_port: 40, usage: sriov}
- {nic_id: 6, switch_id: 2, switch_port: 40, usage: sriov}Extreme traffic switch ports are not configured when a VM is booted in a Neutron network used for SR-IOV. The physical ports used for SR-IOV tenant traffic must be manually configured with the respective Neutron VLAN. Refer to the SW Installation in Multi-Server Deployment document for more information.
3.8 PCI Passthrough
The PCI passthrough feature is configurable on Dell multi-server hardware platform, BSP, and HDS platform, if free NICs are available for PCI passthrough.
PCI passthrough can only be configured using compatible NICs on which the SR-IOV virtualization mode can be disabled. As a result, PCI passthrough is not possible on HDS and Dell servers using Intel Fortville NICs (XXV710-AM1, XXV710-AM2, XL710-AM1, XL710-AM2, XL710-BM1, XL710-BM2, X710-AM2, X710-BM2, XL710-QDA1, XL710-QDA2, X710-DA2, and X710-DA4). If the SR-IOV virtualization mode cannot be disabled, the OpenStack funcionality SR-IOV Physical Function passthrough (PCI passthrough based on type-PF) can be configured and used. In this case, the device type of the interfaces used by Nova is not type-PCI, but type-PF.
To enable PCI passthrough traffic network support, the feature has to be configured in config.yaml in the following places:
- The ericsson_pci_passthrough Fuel plugin must be enabled, refer to the Fuel Plugin Configuration Guide.
- On a per blade basis, using the pci_passthrough key, see Section 3.8.2.
- The PCI aliases optionally on a global level, see Section 3.8.1.
- If using CEE-managed switch configuration (Extreme), in the switch cabling scheme configuration template, see Section 3.8.3.
SR-IOV and PCI passthrough cannot be configured on the same compute host.
- Note:
- The PCI passthrough feature can only be configured when performing the initial deployment of CEE. It cannot be configured during the CEE software update procedure.
- Note:
- To provide High Availability for the VMs using PCI passthrough interfaces, one or more compute servers must be left with free PCI passthrough interfaces for VM evacuation purpose in case of a compute server failure. If each PCI passthrough interface is used in the CEE system, Nova scheduler will fail in case of a compute server failure because of lack of needed resources on other compute servers.
3.8.1 PCI Passthrough Alias Configuration
Arbitrary alias names can be configured for the network devices used for PCI passthrough or SR-IOV Physical Function passthrough functionality. This allows users to specify the alias with the PCI property requirements in the extra_specs of the Nova flavor.
The aliases can be defined under the pci_passthrough_alias key, using the following parameters in a combination:
- device_type is the type of the used PCI device. The value must be type-PCI or type-PF.
- product_id is the product number of the used network device in hexadecimal. This parameter is optional.
- vendor_id is the vendor number of the manufacturer of the network device in hexadecimal. This parameter is optional.
pci_passthrough_alias is an optional parameter. If not configured, the default PCI alias devices PCI_devs and PF_devs are used in the whole CEE region:
- PCI_devs devices can be used by VMs for PCI passthrough (SR-IOV virtualization mode is set to off on the NIC), in which the device_type is type-PCI
- PF_devs devices can be used by VMs for SR-IOV Physical Function passthrough (SR-IOV virtualization mode is set to on on the NIC), in which the device_type is type-PF
Example 72 Example PCI Passthrough Alias Configuration
ericsson:
...
pci_passthrough_alias:
PCI_Intel_X520: {'device_type':'type-PCI', 'vendor_id':'8086', 'product_id':'154d'}
PCI_Intel_device: {'device_type':'type-PCI', 'vendor_id':'8086'}
PCI: {'device_type':'type-PCI'}Example 72 Example PCI Passthrough Alias Configuration
ericsson:
...
pci_passthrough_alias:
PCI_Intel_X520: {'device_type':'type-PCI', 'vendor_id':'8086', 'product_id':'154d'}
PCI_Intel_device: {'device_type':'type-PCI', 'vendor_id':'8086'}
PCI: {'device_type':'type-PCI'}3.8.2 PCI Passthrough Blade Configuration
- Note:
- PCI passthrough can only be enabled on compute hosts.
To define PCI passthrough or SR-IOV Physical Function passthrough on a specific blade, configure the pci_passthrough key with devices properties in the blade section. The pci_passthrough key must be configured for each blade where the PCI passthrough or SR-IOV Physical Function passthrough feature is to be enabled.
It is advised to refer to the devices with aliases that point to pre-defined anchors at the beginning of the configuration file. For information on using aliases, see Section 1.5.1.
Example 73 PCI Passthrough Blade Configuration with Alias
ericsson:
...
pci_passthrough_configs:
- &DELL_620_pci_pt_info
- pci_address: "0000:41:00.0"
- pci_address: "0000:41:00.1"
...
shelf:
-
blade:
-
id: 6
pci_passthrough:
devices: *DELL_620_pci_pt_info
Example 74 PCI Passthrough Blade Configuration without Alias
pci_passthrough:
devices:
- pci_address: "0000:42:00.0"
- pci_address: "0000:42:00.1"devices is a list of dictionaries containing the unique PCI address of each PCI passthrough NIC (Physical Function), where the key of each PCI address is pci_address, and the value is the standard PCI address in double quotes. A minimum of one PCI address must be configured.
3.8.3 PCI Passthrough Cabling Scheme Configuration
In case of CEE-managed switch configuration on Dell platforms, the cabling scheme YAML file must be updated according to the allocation of PCI passthrough ports in the traffic switch. The PCI passthrough ports have the value usage: pci_passthrough. This value is valid for both PCI passthrough or SR-IOV Physical Function passthrough use cases.
Example 75 Example PCI Passthrough Cabling Scheme Configuration
cabling_scheme:
shelves:
- blades:
- blade_id: 6
network interfaces:
- {nic_id: 1, switch_id: 1, switch_port: 1, usage: data}
- {nic_id: 2, switch_id: 2, switch_port: 1, usage: data}
- {nic_id: 3, switch_id: 1, switch_port: 2, usage: storage}
- {nic_id: 4, switch_id: 2, switch_port: 2, usage: storage}
- {nic_id: 5, switch_id: 1, switch_port: 40, usage: pci_passthrough}
- {nic_id: 6, switch_id: 2, switch_port: 40, usage: pci_passthrough}Example 75 Example PCI Passthrough Cabling Scheme Configuration
cabling_scheme:
shelves:
- blades:
- blade_id: 6
network interfaces:
- {nic_id: 1, switch_id: 1, switch_port: 1, usage: data}
- {nic_id: 2, switch_id: 2, switch_port: 1, usage: data}
- {nic_id: 3, switch_id: 1, switch_port: 2, usage: storage}
- {nic_id: 4, switch_id: 2, switch_port: 2, usage: storage}
- {nic_id: 5, switch_id: 1, switch_port: 40, usage: pci_passthrough}
- {nic_id: 6, switch_id: 2, switch_port: 40, usage: pci_passthrough}The physical ports of the traffic switch used for PCI passthrough tenant traffic must be manually configured with the respective VLAN. For more information, refer to:
- Multi-Server System Dimensioning Guide, CEE 6
- In case of BSP deployment: Manage VLAN, Reference [10]
- In case of HDS deployment: Connect an L2 Network to an Ethernet Interface with VLAN Tagging Using REST API in the HDS documentation, Reference [11]
3.9 Bandwidth-Based Scheduling
3.9.1 Nominal Bandwidth of Neutron Physical Networks
The neutron_networks section describes the characteristics of the Neutron physical networks used to identify the physical ports dedicated to CSS physical interfaces. It defines the bond interfaces, Neutron name, and bandwidth capacity.
Format:
neutron_networks:
<neutron-physical-network-name>:
devices:
- <device>
…
bandwidth: <capacity-of-network>
devices lists the interfaces used to bond the network. bandwidth defines the capacity of the network in kbit per second.
- Note:
- In the current release, only the default Neutron physical network is supported, and the devices key is not used.
Example 76 neutron_networks Configuration
ericsson:
...
neutron_networks:
- &neutron_networks_std_limit
control:
devices:
- control0
- control1
bandwidth: 1000000
default:
devices:
- data0
- data1
bandwidth: 10000000
...
shelf:
-
...
blade:
...
-
id: 3
nic_assignment: *DELL_630_nic_assignment
reservedHugepages:
…
reservedCPUs:
...
vswitch_capacity: <vswitch capacity>
neutron_networks: *neutron_networks_std_limit
If SR-IOV is used, the bandwidth of the Neutron physical network is specified in the sriov_configs section. See Section 3.7.1.
3.9.2 vSwitch Capacity
The vswitch_capacity attribute defines the capacity of the virtual switch on each host. The capacity is shown in kilo packet per second. It is used for bandwidth-based scheduling.
Example 77 vswitch_capacity
ericsson:
...
shelf:
-
...
blade:
...
-
id: 3
nic_assignment: *DELL_630_nic_assignment
reservedHugepages:
...
reservedCPUs:
…
vswitch_capacity: <vswitch capacity>- Note:
- For more information about the recommended way to determine the values for vswitch_capacity, refer to the Multi-Server System Dimensioning Guide, CEE 6.
3.10 Neutron Configuration Options
The Neutron configuration file template (selected by using information provided in Section 2.2) can be modified compared to the Ericsson default parameters and values. The change must be part of a system integration activity that includes CEE verification.
- Note:
- CEE was verified only with unchanged Neutron configuration files.
Example 78 neutron_ericsson_user_spec.yaml Template File
# Without further configuration ericsson_user_spec is equivalent to
# ericsson_basic, but ericsson_user_spec is not locked down.
conf_type: ericsson_user_spec
# The .deb files must be included into the Fuel .iso.
# Will be installed on the given target groups.
# Multiple groups are allowed in the target list with comma separation.
# The followin groups are usually enough to install the additional package:
# all - this means the package will be installed on all compute and
# controller nodes
# compute - this means that the package will be installed on all compute nodes
# controller - this means that the package will be instaleed on all controllers
additional_packages:
- name:"<DEBIAN.PACKAGE>"
target:["<TARGET.NODE.GROUP>"]
- name:"<DEBIAN.PACKAGE>"
target:["<TARGET.NODE.GROUP>"]
neutron_configuration_files:
-
name: neutron.conf
option:
# default if next line is not present: no service plugins
DEFAULT/service_plugins: <COMMA.SEPARATED.LIST.OF.SERVICE.PLUGINS>
-
# It is possible to list multiple .ini files here and they will get
# merged into a single plugin.ini.
name: ml2_conf.ini
option:
# default if next line is not present: openvswitch
ml2/mechanism_drivers: <COMMA.SEPARATED.LIST.OF.MECHANISM.DRIVERS>
Example 79 neutron_ericsson_cmx.yaml Template File
conf_type: ericsson_user_spec
additional_packages:
- name: "neutron-plugin-bsp"
target: ["controller"]
neutron_configuration_files:
-
name: ml2_conf.ini
option:
ml2/mechanism_drivers: openvswitch,bsp
-
name: ml2_conf_bsp.ini
option:
ml2_bsp/management_ip: 192.168.2.2
ml2_bsp/audit_interval: 10
ml2_bsp/timeout: 10
ml2_bsp/port_list_restorable: True- Note:
- Do not modify the initial indentation when editing the configuration files.
- additional_packages: list Debian packages included in the .iso Fuel build to be deployed to the controllers during CEE installation. For example, drivers that are not included in the OpenStack distribution, and add functionality inside Neutron. Put each package name in quotation marks. Specify at least one package, otherwise the installation fails.
- neutron_configuration_files: list Neutron configuration files to change or create, refer to OpenStack for valid names.
- name: the name of the section in the corresponding Neutron configuration file. The parameter value is a string that is deployed exactly as it is written.
- option: lists the parameters that the user wants to write in the corresponding Neutron configuration file. Use the following format: <section name>/<key name>: <value>
3.11 Nova Configuration Options
The default values in the nova section is used for a regular deployment scenario. The parameters below are optional. If these parameters are not included in config.yaml, the default values apply. Do not modify the config.yaml file unless the listed use cases are required.
- disk_cachemodes: The cache modes to use for different disk types.
- enable_nova_quotas: The default value is True to enable quota support, False means no Nova quota support.
- force_config_drive: The default value is True, to force injection to take place on a config drive. False means not forcing the injection. The user can still specify the config drive use on boot.
- vms_use_raw_images: The default value is False, that is, cow images are used by the VMs. If it is set to True, then raw images are used instead.
Example 80 Nova Configuration Options
ericsson:
...
nova:
disk_cachemodes: file=directsync,block=none
enable_nova_quotas: true
force_config_drive: true
vms_use_raw_images: false
... 3.12 Hardware Switch Configuration Options
The hw_switches section in the config.yaml template provides the initial_setup parameter. According to the settings in this section, the CEE installation deploys the initial configuration relevant to the used switch type, that is, Extreme traffic and storage switches in Dell multi-server deployments, and CMXB in BSP hardware. No initial hardware switch configuration is used for Single Server CEE and for user-specific Neutron options.
The setting of initial_setup in the hw_switches section must be aligned with the setting of the neutron_config_yaml_file in the neutron section. Table 3 shows the settings that can be used together.
|
Hardware |
neutron: neutron_config_yaml_file: |
hw_switches: initial_setup: |
|---|---|---|
|
neutron_ericsson_cmx.yaml |
cmx | |
|
Dell multi-server(1) |
neutron_ericsson_extreme.yaml |
extreme |
|
neutron_ericsson_user_spec.yaml |
None | |
|
neutron_ericsson_sdn_tight.yaml |
None |
(1) In case of Dell multi-server configuration
with SR-IOV, see Section 3.7.2 for the
correct Neutron configuration.
See the following sections for more information:
- Section 2.3 for hardware switch configuration
- Section 2.2 for Neutron configuration files
- Section 3.10 for Neutron options
Example 81 Neutron Configuration File and Hardware Switch Settings for CMX, BSP
ericsson:
...
neutron:
...
neutron_config_yaml_file: neutron_ericsson_cmx.yaml
...
hw_switches:
initial_setup: cmx
switching_scheme_yaml_file: cmx_switch.yaml
...Example 82 No Hardware Switch Configuration, Single Server
ericsson:
...
neutron:
...
neutron_config_yaml_file: neutron_ericsson_user_spec.yaml
...
hw_switches:
initial_setup: None
... 3.13 Multiple Data Center Gateways
- Note:
- Border Gateway (BGW) is a deprecated term for Data Center Gateway (DC-GW). The term BGW is used in this section.
Two BGWs are specified in the cabling schema, 4_x670v_dell.yaml or 2_x670v_dell.yaml, used for configuring managed Extreme switches:
Example 83 Two BGWs in Cabling Schema
external_components:
border_gateways:
- id: 1
name: BGW-1
switch_id: 1
ports: [49, 50, 51, 52]
master: 49
partition: 4x10G
- id: 2
name: BGW-2
switch_id: 2
ports: [49, 50, 51, 52]
master: 49
partition: 4x10G ...
The BGWs are also specified in the switch configuration file:
Example 84 BGWs in Switch Configuration File
switching:
-
name: TRAFFIC_SWA_X770
device_id: 1
...
bgw_config:
-
id: 1
vlans:
-
name: cee_om_sp
tagged: true
ip: <IP.OF.SWITCH-A/PREFIXSIZE>
-
name: subrack_om_sp
tagged: true
ip: IP.OF.THE.SWITCH/PREFIXSIZE
...
-
name: TRAFFIC_SWB_X770
device_id: 2
...
bgw_config:
-
id: 2
vlans:
-
name: cee_om_sp
tagged: true
ip: <IP.OF.SWITCH-B/PREFIXSIZE>
-
name: subrack_om_sp
tagged: true
ip: IP.OF.THE.SWITCH/PREFIXSIZE
...
Adding further BGWs requires the following:
- Entities must be added to the cabling schema and to the switch configuration file, with increasing IDs.
- The ports used by the additional gateways must be specified.
Example 85 Additional BGW in Cabling Schema
external_components:
border_gateways:
- id: x
name: BGW-x
switch_id: <1 or 2>
ports: [y, y+1, y+2, y+3, ... , y+n]
master: y
partition: 4x10G- Note:
- A partition of 1x40G is also possible, if 40G connections
are used towards the BGW.
Switch ID is 1 or 2, depending on the switch to which the BGW is connected.
The switch configuration file can be updated as shown in the following example:
Example 86 Switch Configuration File Update for Multiple BGWs
switching:
-
name: TRAFFIC_SWA_X770
device_id: <1 or 2>
...
bgw_config:
-
id: z
vlans:
-
name: cee_om_sp
tagged: true
ip: <IP.OF.SWITCH-A/PREFIXSIZE> ⇒
--- (same as the other BGW, in the same switch)
-
name: subrack_om_sp
tagged: true
ip: <IP.OF.THE.SWITCH/PREFIXSIZE> ⇒
--- (same as the other BGW, in the same switch)3.14 Change of Data Center Gateway Settings
To configure the DC-GW with settings different from the default in CEE, the startup configuration of managed Extreme switches must be handled differently for traffic and storage.
Global process:
- If the system is already deployed, change the configuration
version in the following file: /mnt/cee_config/<switch_model>_switch.yaml
switch_config: restore_conf_version: 15B_R4
15B_R4 must be replaced with higher number, for example 15B_R5 - Change the default configuration of the switches in the
following file:
/opt/ecs-fuel-utils/python_libdir/extreme_conf/sw_conf_XXX.xsf - If the hardware configuration contains dedicated storage switches, make sure that the storage-specific default configuration file is named as follows: sw_conf_XXX_storage.xsf. Tip: Make a copy of the original traffic-specific file and add _storage to the name of the new file.
- Modify the default traffic and storage switch configuration
in the files: /opt/ecs-fuel-utils/python_libdir/extreme_conf/sw_conf_XXX.xsf
and
/opt/ecs-fuel-utils/python_libdir/extreme_conf/sw_conf_XXX_storage.xsf
Finally, continue with the normal installation process.
3.15 Time Zone
The time zone to be used on Fuel and the deployed nodes in the CEE region is stated in the config.yaml template. The time zone configured in the templates is UTC (Etc/UTC).
Example 87 Time Zone
ericsson: ... timezone: Etc/UTC ...
For a list of available time zone settings, execute the following
command on a Linux system, for example on the Kickstart Server:
ls -R /usr/share/zoneinfo
3.16 Secure NBI API Endpoints
API NBI endpoints are exposed over SSL/TLS on HTTP. To set the needed trust on the client side, a set of CA certificates must exist.
The options are in the Ericsson namespace, so each option is prefixed with "ericsson".
Example 88 Secure NBI API Options
ericsson:
security:
openssl:
ciphersuites: 'ECDHE-RSA-AES256-GCM-SHA384:ECDHE-ECDSA-AES256-GCM-SHA384:ECDHE-EDSA-AES128-GCM-SHA256:
ECDHE-RSA-AES128-GCM-SHA256'
protocols: TLSv1.2
gnutls:
priority: 'NONE:+SUITEB128:+SUITEB192:+VERS-TLS-1.2'
haproxy:
sslprotocols: no-sslv3 no-tlsv10 no-tlsv11
sslrate: 100
sslconns: 40
nbi:
atlas:
hostname: <ATLAS_HOSTNAME>
certfilename: <ATLAS_CERTFILENAME>
cafilename: <ATLAS_CAFILENAME>
controller:
hostname: <CONTROLLER_HOSTNAME>
certfilename: <CONTROLLER_CERTFILENAME>
cafilename: <CONTROLLER_CAFILENAME>
...
Example 88 Secure NBI API Options
ericsson:
security:
openssl:
ciphersuites: 'ECDHE-RSA-AES256-GCM-SHA384:ECDHE-ECDSA-AES256⇒
-GCM-SHA384:ECDHE-EDSA-AES128-GCM-SHA256:
ECDHE-RSA-AES128-GCM-SHA256'
protocols: TLSv1.2
gnutls:
priority: 'NONE:+SUITEB128:+SUITEB192:+VERS-TLS-1.2'
haproxy:
sslprotocols: no-sslv3 no-tlsv10 no-tlsv11
sslrate: 100
sslconns: 40
nbi:
atlas:
hostname: <ATLAS_HOSTNAME>
certfilename: <ATLAS_CERTFILENAME>
cafilename: <ATLAS_CAFILENAME>
controller:
hostname: <CONTROLLER_HOSTNAME>
certfilename: <CONTROLLER_CERTFILENAME>
cafilename: <CONTROLLER_CAFILENAME>
...
security.openssl.ciphersuites
The string containing the list of allowed OpenSSL cipher suites. Validate the support of cipher suites with the external hosts that use the REST API and change the specified values if needed.
Examples on external hosts using the REST API:
- Network Function Virtualization Orchestrator (NFVO), for example, Ericsson Cloud Manager (ECM)
- Virtualized Network Function Manager (VNFM)
- Note:
- The order of the listed cipher suites signifies the precedence honored by CEE components.
Recommended setting:
ECDHE-RSA-AES256-GCM-SHA384:ECDHE-ECDSA-AES256-GCM-SHA384:ECDHE-ECDSA-AES128-GCM-SHA256:ECDHE-RSA-AES128-GCM-SHA256
security.openssl.protocols
The string containing the list of allowed SSL/TLS protocols.
Recommended setting: TLSv1.2
security.gnutls.priority
The string containing gnuTLS protocol/ciphersuite settings.
Recommended setting:
NONE:+SUITEB128:+SUITEB192:+VERS-TLS-1.2
security.haproxy.sslprotocols
The string containing accepted/disabled SSL/TLS protocols to offer.
Recommended setting:
no-sslv3 no-tlsv10 no-tlsv11
security.haproxy.sslrate
The number of SSL sessions allowed to be established per second.
Recommended setting: 100
Recommended
setting for Dell Single server: 20
security.haproxy.sslconns
The number of SSL connections to allow per listener.
Recommended setting: 40
- Note:
- One session requires two connections.
security.nbi.controller.hostname
The string containing the hostname by which the CIC is referenced through the NBI.
security.nbi.controller.certfilename
The string containing the filename (relative to /mnt/cee_config) of the CIC certificate.
security.nbi.controller.cafilename
The string containing the filename (relative to /mnt/cee_config) of the CA certificate signing the CIC certificate.
security.nbi.atlas.hostname
The string containing the hostname of the Atlas VM that is reachable from the vCICs. Only needed if Atlas is installed.
security.nbi.atlas.certfilename
The string containing the filename (relative to /mnt/cee_config) of the Atlas certificate when Atlas is installed.
security.nbi.atlas.cafilename
The string containing the filename (relative to /mnt/cee_config) of the CA certificate signing the Atlas certificate if Atlas is installed.
The hostnames for the vCICs and Atlas are user-supplied. End users must make sure that their hostnames are unique and the hostnames used for cloud endpoints are resolving to the proper IP addresses. The hostnames must conform to RFC 952, Reference [7] and RFC 1123, Reference [8].
- Note:
- The certification files are either acquired from a third party or generated by own CA authority, and out of scope of this document. Refer to the SW Installation in Single Server Deployment and SW Installation in Multi-server Deployment for more information on the certificate for the Northbound Interface (NBI) required for secure HTTPS access to CEE.
3.17 Fuel Administration Network
fuel_ctrl_sp is used for PXE boot of compute hosts (host OS) and vCIC nodes.
The network can be configured under the networks key in the config.yaml template:
Example 89 Fuel Administration Network
ericsson:
...
networks:
...
-
name: fuel_ctrl_sp
mos_name: fuelweb_admin
cidr: 192.168.0.11/24
dhcp_pool_start: 192.168.0.20
dhcp_pool_end: 192.168.0.253
gateway: 192.168.0.254
dns: 10.51.40.100
...
If the IP address of the Fuel administration network is different from the network specified in config.yaml and the IP and VLAN plan Reference [1], update fuel_ctrl_sp before running CEE_RELEASE/scripts/install_vfuel.sh.
- Note:
- Make sure that the Fuel IP is not included in the dynamic IP range of dhcp_pool_start and dhcp_pool_end.
3.18 Location of Logs
The location of core and crash dump logs can be changed using the following parameters:
Example 90 Crashes Stored Locally
ericsson:
...
logging:
crashes: local
forward_to_fuel: false
forward_to_controller: true
forward_to_external: false
external_server_ip:
external_server_port:
local_on_controller: true
local_on_compute: false
...
Example 91 Setting Server IP and Port for External Server
ericsson:
...
logging:
forward_to_fuel: false
forward_to_controller: true
forward_to_external: true
external_server_ip: 1.2.3.4
external_server_port: 5678
local_on_controller: true
local_on_compute: false
...- Note:
- The boolean parameters of logging must be included in the config.yaml. The default values mentioned below refer to the values originally set in the template.
crashes
The destination of crashes (core and kernel crash dumps). crashes can have the value local or cics. Dell and single server store crashes locally in each blade or server by default. BSP stores most crashes in the vCICs, BSP still saves crashes locally where possible, since disk space is scarce in most BSP installations. If cics is selected for single server, local crashes are still used when needed, for example at compute host kernel crash or core dump of QEMU.
forward_to_fuel
Indicates whether to forward logs from both vCICs and compute hosts to Fuel or not. Boolean parameter, default value: false
forward_to_controller
Indicates whether to forward logs from compute hosts to vCIC or not. Boolean parameter, default value: false on Dell and Single Server, true on BSP
forward_to_external
Indicates whether to forward logs from both vCIC and compute host to an external log server or not. Boolean parameter, default value: false
external_server_ip
The IP address of an external log server. Mandatory if forward_to_external is set to true
external_server_port
The port of an external log server. Mandatory if forward_to_external is set to true
local_on_controller
Enable or disable local logging on vCIC. Boolean parameter, default value: true
local_on_compute
Enable or disable local logging on compute hosts. Boolean parameter, default value: true on Dell and Single Server, false on BSP.
auditlog_local
If enabled, up to three audit logs will be stored on the vCICs in /var/log/audittrail. The size of an audit log is 50 MiB.
This Boolean parameter is optional. If omitted, the default value false is configured.
auditlog_remote
Enable or disable audit log forwarding to the SBI, if the SBI address is configured.
This Boolean parameter is optional. If omitted, the default value true is configured.
3.19 Link Monitoring for CEE on BSP
- Note:
- Port state tracking is only applicable to BSP R9.1 and later releases.
Link monitoring for CEE on BSP is implemented using port state tracking, To enable port state tracking, configure the following settings:
Example 92 Port State Tracking Configuration
ericsson:
...
port_state_tracking:
enabled: <TRUE/FALSE>Port state tracking is implemented for the control and traffic networks with the following mandatory parameter:
- enabled: If this parameter is set to True, the system automatically configures port state tracking in CEE. The parameter is set to True in the config.yaml template.
If enabled is set to True, the bond settings must be configured in host_nw_bsp.yaml. The bond setting is pre-configured in the template. The following parameters are needed:
Example 94 Host Network Template Configuration for Port State Tracking
- action: add-bond
bond_properties:
mode: active-backup
use_carrier: 0
downdelay: 0
miimon: 100
bridge: br-fw-admin
interfaces:
- <% if1 %>
- <% if2 %>
name: bond-fw-admin
provider: ovs
3.20 Reduced Footprint Monitoring Data Collection
- Note:
- The reduced_footprint key is deprecated and will be removed in the next major release. For more information, refer to the Preconfigured Key Performance Indicators.
reduced_footprint enables reduced KPI data collection in Zabbix to save storage, computing, and network resources. It uses a set of alternative KPI/metric lists for Zabbix that gather and store less measurement data.
monitoring_data_collection default value is false.
Both keys are optional, if omitted, the default value applies.
Example 95 Reduced Footprint
ericsson:
...
reduced_footprint:
monitoring_data_collection: false
...
3.21 Zabbix CEE User
The zabbix_cee_user section contains configuration options to configure the user group, username, and password of the read-only user in Zabbix. All keys are optional. If the keys are not present, the following default values are used for the user group, user, and password, respectively:
- CEEUserGroup
- ceeuser
- An automatically generated secure password
Example 96 Zabbix CEE User
ericsson:
...
zabbix_cee_user:
zabbix_user_group: <ZABBIX_USER_GROUP>
zabbix_user: <ZABBIX_USER>
zabbix_password: <ZABBIX_PASSWORD>
...
zabbix_user_group: String, the name of the user group. The value admin cannot be used, because the global access administrator user "admin" exists by default and cannot be overwritten.
zabbix_user: String, the name of the user.
zabbix_password: String, the password of the user.
Use single quote marks as shown in the example below:
Example 97 Zabbix CEE User Example
ericsson:
...
zabbix_cee_user:
zabbix_user_group: ‘CEEUserGroup’
zabbix_user: ‘ceeuser’
zabbix_password: ‘examplepassword’
...
3.22 Excluding Disk At Deployment
Any disk attached to a compute blade is mounted and erased as part of the CEE deployment.
One or more disks can be configured to be excluded from the CEE deployment by defining the exclude_disks key for the blade to which the disk is attached.
Example 98 Excluding Disks from CEE Deployment
ericsson:
...
shelf:
-
id: 0
blade:
-
id: 1
exclude_disks: disk/by-id/<DISK_ID>
...
-
id: 2
exclude_disks:
- disk/by-id/<DISK_ID>
- disk/by-id/<DISK_ID>>Multiple disks to be excluded must be submitted in list format.
The disks are specified using the disk names without the leading /dev.
- Note:
- It is recommended to use disk/by-path or disk/by-id names. Do not use standard device names such as sdb, as their mapping to the physical disk is not guaranteed to be consistent.
3.23 Deployment Debugging Information
- Note:
- The debugging logs can contain sensitive data, including password hashes, and user-password pairings. As such, the use of debug_deploy is not recommended in production environments.
Debugging information can be logged during CEE installation, by defining the optional debug_deploy key. The logs can be used to troubleshoot deployment issues.
Example 99 Enabling Deployment Debugging
ericsson: ... debug_deploy: true
If the parameter is true, logs about the deployment will be stored in the /var/log/puppet.log file on each node apart from vFuel (compute host, vCIC, ScaleIO). The default value for debug_deploy is false.
Reference List
| [1] IP and VLAN plan, 2/102 62-CRA 119 1862/5 Uen |
| [2] VNX5400 SW Installation, 3/1531-CSA 113 125/5 Uen |
| [3] BSP External Network Connectivity, 2/1553-APP 111 01 Uen |
| [4] YAML Specification. http://www.yaml.org/spec/1.2/spec.html |
| [5] CEE Network Infrastructure, 1/102 62-CRA 119 1862/5 Uen |
| [6] CEE Architecture Description, 5/155 53-AZE 102 01 Uen |
| [7] DoD Internet Host Table Specification. https://tools.ietf.org/html/rfc952 |
| [8] Requirements for Internet Hosts -- Application and Support. https://tools.ietf.org/html/rfc1123 |
| [9] CSS User Guide, 1553-AXT 901 11/2-V1 |
| [10] Manage VLAN, 12/1543-APR 901 0549/1 Uen |
| [11] Hyperscale Datacenter System 8000 Customer Product Information. https://ewstest.ericsson.com/hyperscale/cloud-infrastructure/hyperscale-datacenter-system/hds-8000-product-information/ |