1 Introduction
This instruction concerns alarm handling.
1.1 Alarm Description
The NTP Upstream Server Failure alarm is issued by the Managed Object (MO) UpstreamNTPServerConnection. The alarm is issued when the NTP client on the virtual Cloud Infrastructure Controller (vCIC) nodes cannot reach one of the upstream servers in the NTP server list.
The possible alarm causes and the corresponding fault reasons, fault locations, and impacts are described in Table 1.
|
Alarm |
Description |
Fault |
Fault |
Impact |
|---|---|---|---|---|
|
Upstream server not reachable. |
Specified compute host which hosts the vCIC cannot reach one of the upstream servers. |
|
Upstream NTP server |
The time on the compute hosts which host the vCICs and other nodes might be unsynchronized with UTC time server. Therefore the time on the compute host which hosts the vCIC and other nodes might not have the correct UTC time. |
|
Upstream NTP Server, or the compute host which hosts the vCICs, or router, or switch in the network from the compute host which hosts the vCIC to the upstream NTP servers. | |||
|
vCIC host | |||
|
Upstream NTP server |
- Note:
- An alarm can appear as a result of the maintenance activity.
The following is the consequence for the node if the alarm is not solved:
- The time on the compute hosts which host the vCICs and other nodes are not synchronized with UTC time server and may not have the correct UTC time.
- The impact can be reduced redundancy or complete loss of NTP service from external sources to CEE. This depends on the number of NTP servers that are working and used.
The alarm attributes are listed in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Major Type |
193 |
|
Minor Type |
2031709 |
|
Managed Object Class |
UpstreamNTPServerConnection |
|
Managed Object Instance |
Region=<name_of_the_region>, |
|
Specific Problem |
NTP Upstream Server Failure |
|
Event Type |
other (1) |
|
Probable Cause |
realTimeClockFailure (70) |
|
Additional Text |
NTP error |
|
Severity |
MINOR (5) |
1.2 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
The following documents are needed to solve the alarm:
1.2.2 Tools
No tools are required.
1.2.3 Conditions
Before starting this procedure, ensure that the following condition is met:
- SSH credentials for the compute hosts which host the vCICs and the compute host are available.
- An NTP Upstream Server Failure alarm is active.
2 Procedure
This section describes the procedure to follow when this alarm is active.
2.1 Actions for Solving the Alarm
This section describes the procedure to follow when the alarm is active.
The following example output is taken from a controller node, compute-0-6.
Do the following:
- Fetch information from the servers
by executing the following command on the compute hosts which host
the vCICs:
ntpq -c as
Example of output:ind
assid
status
conf
reach
auth
condition
last_event
cnt
1
29326
9024
yes
yes
none
reject
reachable
2
2
29327
9024
yes
yes
none
reject
reachable
2
3
29328
f61d
yes
yes
none
sys.peer
1
4
29329
c01c
yes
no(1)
none
reject
1
5
29330
c01c
yes
yes
none
candidate
1
6
29331
c011
yes
yes
none
candidate
mobilize
1
(1) failure indication
- List the NTP servers information
by executing the command:
root@compute-0-2:~# ntpq -p
Example of output:remote
refid
st
t
when
poll
reach
delay
offset
jitter
compute-0-6.domain.
10.35.50.5
5
u
66
1024
377
0.295
-0.139
0.497
compute-0-5.domain.
10.35.50.5
5
u
888
1024
376
0.180
0.089
0.107
*10.35.50.5
192.168.50.4
4
u
347
1024
377
0.236
1.920
0.039
seki20-ntp4.k2.
.INIT.
16
u
-
1024
0
0.000
0.000
0.000
192.168.6.1
10.35.50.6
4
u
68
1024
377
0.123
1.631
0.109
google-public-d
10.35.50.6
4
u
251
1024
377
0.256
0.928
0.171
- List the NTP server
configuration on the compute hosts which host the vCICs with the following
command:
cat /etc/ntp.conf |grep server
The output example is:
server 10.35.50.5 burst iburst
server 10.51.40.103 burst iburst
server 192.168.6.1 burst iburst
server 8.8.4.4 burst iburst - The failure indication of Step 1 shows that server 4 has the value no in the reach column.
This indicates that the vCIC has general problem to reach its upstream
NTP servers.
If the auth column has a value bad for any of the servers, debug further according to NTP Authentication Failure.
Check which servers have no in the column reach. In the example output, server 4 shows the status no in the column reach. This means that the compute host which hosts the vCIC is not able to reach upstream server 4.
To find the hostname of the server, compare the printout from Step 1 and Step 2. The servers are listed in the same order in both printouts. The server hostnames or IP addresses are listed in the remote column in the printout in Step 2.
To find the IP address of the server, compare printouts from Step 2 and Step 3. In Step 3, the upstream NTP servers IP addresses are listed in the first column. The vCICs are not listed in the printout in Step 3, but the order is the same.
In this example, in Step 1, server 4 has reach status no, which indicates a problem with the upstream NTP server.
Server 4 shown in Step 2 has hostname seki20-ntp4.k2., and the IP address is 10.51.40.103. Therefore, the vCIC has reported to have upstream server failure with the following servers in the /etc/ntp.conf
server 10.51.40.103 burst iburst - Test the network connection, using ping <upstream_server> to verify the network connection from the vCIC to the upstream
NTP server.
If there is no response from the ping command, continue with Step 8.
If there is a response from the NTP server, continue with Step 6.
- Check the authentication
status of the NTP servers. Follow the guide below to find out which
action to perform.
Authentication Status
Go To
Indication
auth: bad
Failed authentication
auth: none
This OPI
No authentication
- If there is no authentication
configured (that is auth: none), do the following:
- Check the local configuration file
- Update the configuration file
- Restart the NTP service with the following command:
sudo service ntp restart
When the issue is fixed, the NTP Upstream Server Failure alarm disappears from the alarm list.
- In case the alarm persists, do the
following:
- Collect all output obtained in Step 1– Step 7.
- Collect troubleshooting data as described in the Data Collection Guideline.
- Note:
- Alarm logs from Atlas and Linux console as generated from the system when following this OPI.
- Consult the next level of maintenance support with all collected information.
Further actions are outside the scope of this instruction.
- The job is completed.