FC STM-1 Manager C7.0 (Build 7.0.9)



Copyright © 2009 Nokia Siemens Networks. All rights reserved.

Contents

Introduction
System Requirements
Compatibility
Installation
Uninstallation
Document Errata
Version History
Known Issues
Other Information



Introduction

This document provides some important information about FC STM-1 Manager (referred to as "the Element Manager" or "the EM" hereinafter). Please read this (as well as the documentation for the Elements involved) through before using the Element Manager.

There is more detailed information also in the online Help of the Element Manager.

This Element Manager is used for managing the FC STM-1 unit in MetroSite BTS or ConnectSite 10 BTS.
 

Back to Contents



System Requirements

In order to use the Element Manager, you need the following:

  • Operating System (English versions):
    • Microsoft Windows 2000 Server
    • Microsoft Windows XP Professional
    • Microsoft Windows 2003 Server
    • Microsoft Windows Vista

The Element Manager does NOT officially support any other Windows Operating Systems.
 

  • An Intel Pentium compatible PC:
    • Processor: min. 300 MHz (recommended 500 MHz or more)
    • Memory: according to installed operating system (preferably the recommended amount)
    • Monitor: min. SVGA with 800x600 resolution (recommended 1024x768 resolution)
    • Hard disk: 10 MB free space exclusively for the Element Manager installation (recommended 25 MB)
    • Pointing device: mouse, trackball, touchpad or equivalent
    • CD-ROM drive
    • (local connection) 9-pin serial port in the PC
    • (local connection) LMP cable (see more details in section Other Information)
    • (remote connection) Network adapter with connection to DCN
    • (optional) Windows compatible printer


Back to Contents



Compatibility

This Element Manager release is compatible with the following:
 

Item

Product Version

 HW Version

SW Version

FC STM-1 Card

03, 04, A0, B0, C0

Bridge: 00002793 02, A0,

 

STM-1: 00002794 03, A0,

Bridge PDH part:

00003784 C0, B0, A0, 00

 

Bridge SDH part:

00003783 C0, B0, A0, 00

 

STM1 part:

00003781 C0, B0, A0, 00

Bridge Manager

-

-

C7.0 (build 7.0.9)

STM-1 Manager

-

-

C7.0 (build 7.0.9)

BTS Manager

-

-

CX6 CD2.0

GCS communication stack

-

-

4.2, 5.0, 6.0

NetAct

-

-

NetAct OSS4.1, NetAct OSS4.2

The Element Manager is a part of SiteWizard 6 CD4.0. 

Back to Contents



Installation

You can obtain the Element Manager through SiteWizard CD-ROM or you can download it via https://www.online.nokia.com/SWD/: Software Delivery > Operations Support Systems > Element Management Products > SiteWizard.

To install the Element Manager, follow the instructions of the SiteWizard installation program.
The installation program should start automatically when the CD-ROM is inserted in the CD-ROM drive. If it does not start, run setup.exe from the CD-ROM manually.

If you received the Element Manager Installation package as a compressed file (.zip), extract the zip file contents into some temporary directory in your hard disk. Then run setup.exe from the directory. After the installation is completed, you can delete the temporary directory and its contents.

The Element Manager files are installed into the directory you selected during the installation (referred to as "Installation Directory").

The Element Manager startup (shortcut) icon is added into the "Nokia Siemens Networks" folder.

The Element Manager executable "FCSTM1Man.exe" is located in the Installation Directory.

To use connection services of the Element manager, GCS communication service (as per the compatibility chart above) must be installed.

 

Back to Contents



Uninstallation

To uninstall the Element Manager, follow the normal Windows application uninstallation procedure (from the Control Panel select Add/Remove Programs).
For more details, see the online Help of the Operating System.

NOTE: If you have saved some extra files (logs, configurations, etc.) to the Element Manager directory, those files and the directory will NOT be deleted. You need to remove them by yourself.
 

Back to Contents



Document Errata

There are no significant documentation updates.
 

Back to Contents



Version History

The Element Manager changes in release 1.1 (Build 1.1.10) are:

Features Removed

  • PB2 type CC removed from PDH part as the condition for this type of CC cannot be set in a pure SDH node.
  • "Transmission Unit Manager" menu item in Help menu removed.

Features Added

  • New Synchronization functionality.
  • Q1 scripter tool can be launched from the manager.
  • XML file save - Displays message box saying XML file does not save all the settings that are saved by the node file.

Bugs Fixed

  • Pronto # 8747ES09P : Manager crashes when you select wrong kind of .xml-file.
  • Pronto # 2498ES38 : During CC bank activation status bar info is incorrect.
  • Pronto # 8909ES11P : Q1 Management->Routing->Help

The Element Manager changes in release 2.0 (Build 2.0.14) are:

Requirements Implemented

  • FXC_SysRqt_0720 - SDH protection switch for FC STM-1.
  • ITN_SysRqt0808 - Full Xml Support.
  • ITN_SysRqt0801 - Traffic Manager to support STM-1.
  • ITN_SysRqt0880 - User access levels to Element Managers.
  • ITN_SysRqt0940 - Addition, modification support for nx8k CC.
  • Retransmission support while downloading a node software.
  • EM setups should clean the registry during uninstallation.
  • ITN_SysRqt0760 - Selection of Bridge TS in SDH-PDH CC creation.

Features Added

  • FXC STM & Bridge alignment.
  • Help Updated.

Features Modified

  • CRC checksum problem with SDH protected Cross-connections.
  • COM port change - Number of selectable COM ports should be more than 4.

Features removed

  • None

Bugs Fixed

  • Pronto # 2354ES11P : Help problems.
  • Pronto # 2528ES11P : FC-STM1 Manager does not work properly with command line parameters.
  • Pronto # 8260ES11P : After factory defaults -reset to whole node (MS BTS with FC STM-1) FC STM Manager (C1.0-1 Build 1.0.7) shows Bridge -part as 'not installed' although it is installed.
  • Pronto # 9295ES11P : XML-files for US BTS and MHB can be used in commissioning of MS BTS with FC STM-1 Manager C1.0-1.
  • Pronto # 11534ES11P : Wrong kind of .xml file causes troubles with restore backup settings.
  • Pronto # 9272ES11P : Problems with uninstalling BTSMan or FC STM-1 Man when using Windows 2000 or XP.
  • Pronto # 8058ES11P : Inactive XC bank does not empty after HW Reset when Bridge in node.
  • Pronto # 13082ES11P : FC Bridge PDH SWDL dialog does not accept pkz files.
  • Pronto # 9273ES11P : Win2000 and WinXP startup menu contains useless C2.1 startup icons for HubMan and UBHubMan when SiteWizard is updated to C2.2.
  • Pronto # 1-54191373 : Combined 32K OMU&TRXSIG on TCH.
  • Pronto # 3489ES42 : 'Received TTI' field not updated automatically.
  • Pronto # 13245ES11P : FXC STM1 Commissioning - Commissioning STM1 causes NM to crash.
  • Pronto # 11270ES08P : CC wizard keyboard keys not same as previous releases.
  • Pronto # 2741ES11P : It's not possible to make CC with Tab and arrow keys.
  • Pronto # 12898ES11P : Help button is missing from CC properties dialog.
  • Pronto # 12946ES11P : Extra space character in splash screen.
  • Pronto # 14886ES09P : Saving node settings with HubMan / USBTSHubMan fails.
  • Pronto # 2376ES11P : & Symbol not displayed in CC Bank.
  • Pronto # P234602 : Time stamp in the top of the alarm-view doesn't update when Refresh All is pressed.
  • Pronto # 9994ES11P : Q1 Ext connection does not recover after chainging speed.
  • Pronto # 8276ES11P : EOC Cross-connections cannot be modified.
  • pronto # P274502 : "LYNX -- Node Manager -- Hub Manager Q1 EOC connections in the inactive CC bank window can not be modified".
  • Installation Problem related to GCS - Failure message changed.
  • Pronto # 13553ES11P : Help problems with FC STM-1.
  • Pronto # 8775ES10P : Bridge PDH SWDL - Downloading corrupted SW leads to different results.
  • Pronto # 8767ES10P : Bridge PDH SWDL - Downloading of incorrect SW gives different results in FXC as in FC.
  • Pronto # 8774ES10P : FXC Bridge SWDL - After aborting a SWDL, the window will not update.
  • Pronto # 12286ES11P : Software download cancellation with FXCBridge possible without further confirmation.
  • Pronto # 13719ES11P : Clock calibration not possible with FC STM-1 Manager.
  • Pronto # 13739ES11P : SDH-PDH Channel NM - Refresh button on SDH_PDH Channel does not refresh all settings.
  • Pronto # 5692ES11P : Severity state change of alarms - handled differently on different cards / different equipment.
  • Pronto # 13980ES11P : SDH Traffic Manager - Missing mapping to STM-1 VC-12 channel.
  • Pronto # 13960ES11P : Fault on Abis allocation list on UltraSite BTS with FXC STM/Bridge cards.
  • Pronto # 14107ES11P : Factory defaults and Commissioning wizard factory default are NOK in FCSTM1Man.
  • Pronto # 14179ES11P : Reset Factory Defaults can not be selected for Bridge SDH in FC STM-1 manager.
  • Pronto # 14216ES11P : Q1 Routing: Switch 'InternalToExternal' missing in online mode of FC STM-1 manager.
  • Pronto # 14274ES11P : FC STM: Bridge SDH Reset Counter is not updated in the STM-1 manager after HW reset.
  • Pronto # 14294ES11P : FC STM-1 Manager does not support ITN_SysReq0763.
  • Pronto # 14524ES11P : Warnbox 'FXC STM-1 unit missing' is misleading in case of FC STM-1 unit.
  • Pronto # 14532ES11P : FC STM-1 HW IDs are not stored correctly in node file (*.nod, *.xml).
  • Pronto # 14166ES11P : Quality alert while calibrating though reference source had quality G.811.
  • Pronto # 14568ES11P : Modify Bridge resource allocation during XC creation does not work correctly in node manager.
  • Pronto # 14192ES11P : CC mismatch alarm when cc created with Traffic Manager (PDH node).
  • Pronto # 14803ES11P : Wrong version info in Print review.
  • Pronto # 14867ES11P : Wrong version info in alarm view print preview in FC STM-1 manager.
  • Pronto # 15047ES11P : UALC feature does not prohibit remote modification of system although feature installed and enabled.
  • Pronto # 15040ES11P : Element Manager always tries to connect to COM1.
  • Pronto # 14957ES11P : All Tools->Options settings are not saved when exit.
  • Pronto # 14610ES11P : Pending cross-connections are not displayed correctly in cross-connection window.
  • Pronto # 9272ES11P : Problems with uninstalling BTSMan or FC STM-1 Man when using Windows 2000 or XP.
  • Pronto # 14593ES11P : Accept Site Selection -dialog in Commissioning Wizard shows 'Site Name' from the Node and not from the xml-file.
  • Pronto # 14900ES11P : Alarm monitoring settings not visible where expected in Configuration report.
  • Pronto # 15344ES11P : MS is shown as a CS10 in FC-STM-1 Manager.
  • Pronto # 15533ES11P : Embedded Bridge and STM-1 starts in read-only mode in file-mode with FC-STM-1 manager.
  • Pronto # 15521ES11P : The Bridge and FC STM1 manager crash during the remote activation of the FC Bridge PDH SW.

The Element Manager changes in release 5.0 (Build 5.0.9) are:

Requirements Implemented

  • ITN_SysRqt0961 - Traffic manager should support crossconnection protection in SDH
  • ITN_SysRqt0787 : Polling of Alarms in a separate thread
  • ITN_SysRqt0967 : Full Loop Wizard(Undo the code for LoopWizard).Pilotbits check box functionality should be developed
  • ITN_SysRqt0922 : A user shall be informed if there are inconsistencies between the cross-connection data represented towards the user via Element Manager and the actual cross-connection data at the ITN/FC STM node. If a inconsistency occured user shall be able to upload the cross-connection data from the ITN/FC STM node to re-establish consistency.
  • ITN_SysRqt0309 : Remote change of Q1 NE address and baudrate
  • ITN_SysRqtxxxx : Remove the OS-Laser Control State saving and reading to/from file
  • ITN_SysRqt0977 : Node Status Report
  • ITN_SysRqt0978 : Part of Node Status (ITN_SysRqt0977) generation of the customer report from one dialogue, excluding ability to cancel
  • FXC_SysRqt_0407 : RAML 2.1 support limited to updation of "AdaptationVersionMajor
  • COMITN_xxx : Change of Version number of the EM to C5. Internal version to be changed to 5.0

Features Added

  • None

Features Modified

  • None

Features removed

  • None

Bugs Fixed

  • Pronto # 13045ES10P : STM-1 CC - Protected CC with Traffic Mgr Interface not shown
  • Pronto # 18319ES11P : Invalid File error while downloading FcSTM Software
  • Pronto # 18293ES11P : STM-1 CC - Protected CC with Traffic Mgr, Node Mgr Crashes
  • Pronto # 13076ES10P : SDH Prot CC - Change from loop to chain in SDH Traffic Mgr not possible
  • Pronto # 18379ES11P : FCSTM Element Manager doesn't use the bulk command(k:6,5,999)
  • Pronto # 18470ES11P : Wrong Version in node report
  • Pronto # 19299ES11P : FCSTM1 Manager gives error on 'Reset to Factory Defaults' and 'Install All'
  • Pronto # 15625ES11P : After refreshing the cross-connections the symbol in case of pending XCs disappears or changes its type
  • Pronto # 14610ES11P : Pending cross-connections are not displayed correctly in cross-connection window
  • Pronto # 17100ES11P : Export of alarm history in file contains only deactivation dates, activations dates are missing
  • Pronto # 15592ES11P : Changing the Q1 address or speed is not possible with a remote connection
  • Pronto # 1-97391385 : Disabled Q1 port settings
  • Pronto # 19961ES11P : DBus 13 doesn't work
  • Pronto # 14448ES11P : The FC STM Alarm properties lists for node and units are not correct when connected to the BTS
  • Pronto # 15793ES11P : MetroSite node file restore may fail due to corrupted communication parameters
  • Pronto # 14107ES11P : Factory defaults and Commissioning wizard factory default are NOK in FCSTM1Man
  • Pronto # 15583ES11P : FC STM1 measuement HW reset counter name is incorrect
  • Pronto # 15713ES11P : After Real Time update the previous Statistics History records in FXC SDH units are not available anymore
  • Pronto # 15583ES11P : FC STM1 measuement HW reset counter name is incorrect
  • Pronto # 20417ES11P : The problem occurs because the SWDL summary window is not implented in Bridge Manager
  • Pronto # 20395ES11P : Can not modify the new EOC via remote connection
  • Pronto # 20519ES11P : Cross-Connections disappear in Inactive bank when EOC is created for FCSTM
  • Pronto # 14497ES11P : Refresh button missing at FXC/FC STM-1 VC-4/TUG dialogue
  • Pronto # 14107ES11P : Factory defaults and Commissioning wizard factory default are NOK in FCSTM1Man
  • Pronto # 20531ES11P : Message 'Illegal Comand' by reading Cross-connection on FC STM-1 Card
  • Pronto # 14447ES11P : The FC STM Alarm properties lists for node and units are not correct in offline mode
  • Pronto # 14448ES11P : The FC STM Alarm properties lists for node and units are not correct when connected to the BTS
  • Pronto # 21471ES11P : FC STM-1 User Info is not restored completely
  • Pronto # 21427ES11P : Missing Site Location Information if restoring Backup settings with the stand alone FC STM-1 Manager
  • Pronto # 14107ES11P : Factory defaults and Commissioning wizard factory default are NOK in FCSTM1Man
  • Pronto # 21456ES11P : Wrong xml content specification version used inside the EM xml files.
  • Pronto # 21152ES11P : Text missprinted in Action section of enhance Error Handling
  • Pronto # 21155ES11P : GUI: Too many spaces between release and build numbers
  • Pronto # 5067C01 : Error while uninstalling FXC STM unit
  • Pronto # 21666ES11P : USBTS EM: Inconsistency between graphical view and list view of Cross Connections
  • Pronto # 19220ES11P : Restore of backup settings failed
  • Pronto # 21650ES11P : Problem at creation of Uni_Directional CC in FC-STM1 EM
  • Pronto # 20274ES11P : Error in CC-overview dialog
  • Pronto # 34017ES09P : Company name incorrect in splash screen
  • Pronto # 22307ES11P : Protecting ABIS on SDH interface is shown as CHAIN in Traffic Manager Necessary Information Missing

The Element Manager changes in release 6.0 (Build 6.0.8) are:

Requirements Implemented

  • Bulk Command Implementation for STM1 for CRC4 Multifranme
  • C3CD2_1 : Measurement/Display of internal +5V/-5V
  • C3CD2_1 : Measurement/Display of internal +5V/-5V
  • C3CD2_23 : Improvement of alarm logging file
  • C3CD2_26 : Alarm rationalization (phase 2)
  • C3CD2_30 : Compatibility Management change
  • C3CD2_5 : A new Unit should enable to upgrade a complete node to the new SW status : SW copy functionality
  • C3CD2_12 : Re-branding UI to Nokia Siemens Networks style
  • C3CD2_5 : A new Unit should enable to upgrade a complete node to the new SW status : All / Activating the software : remaining : to be

Features Added

  • None

Features Modified

  • None

Features removed

  • None

Bugs Fixed

  • Pronto # 22528ES11P : HubMgr after reopen traffic mgr with node file and add SDH units
  • Pronto # 5821C01 : Bulk command k:6,5,4 not sent for PDH Monitoring
  • Pronto # 5840C02 : "SDH-PDH Channels" dialogue gives error while opening
  • Pronto # 22496ES11P : VC12 configured for ABIS can not be selected, during traffic setup
  • Pronto # 6223C02 : E1T1 Delete Signal for OMUSIGTRXSIG1 is not working properly
  • Pronto # 6198C02 : US,MH:Manager is not able to handle conflict for TRXSIG on TCH
  • Pronto # 6200C02 : MH: Delete All operation is not happening smooth for STM1 Abis allocation
  • Pronto # 14052ESPE01: The +5/-5V unit measurement values are displayed incorrectly in the node status report
  • Pronto # 5446C01 : Incorrect message displayed by EM when changing VC12 Mapping mode
  • Pronto # 14448ES11P : The FC STM Alarm properties lists for node and units are not correct when connected to the BTS
  • Pronto # 9195ES05X : US,MH: Compatibility menu is enabled when node SW on all the cards is less than C3.1
  • Pronto # 21419ES11P : wrong port settings for the service interface in factory default within the stand alone FC STM-1 Manager
  • Pronto # 9318ES05X : TRX numbers used in EDAP are displayed under the title 'Traffic Manager' in Traffic Manager window
  • Pronto # 9411ES05X : BTS Manager hangs when attempted to delete multiple conflicts cross-connection in the Inactive bank when RRI is on slot-3 of ultrasite
  • Pronto # 6043ESPE06 : Cross connection mismatch window occurs unexpected
  • Pronto # 6084ESPE06 : SW compatibility management recommends old software
  • Pronto # 14447ES11P : The FC STM Alarm properties lists for node and units are not correct in offline mode
  • Pronto # PR9471ES05X: MH US_EMA Manager crashes when deleting a conflicting signal from a imported file
  • Pronto # 9611ES05X : SW activation is not happening via SW upgrade dialogue
  • Pronto # 9540ES05X : Element Manager Crashes In Metrosite when Software Upgrade menu is selected.
  • Pronto # 9612ES05X : FCSTM1 : SW download via SW Upgrade dialogue is not happening for Bridge SDH
  • Pronto # 9610ES05X : FCSTM1 : Incompatibility is not getting detected by SW compatibility and SW upgrade dialogue
  • Pronto # 9551ES05X : Software Upgrade Window doesn't Shows Incompatibility in Metrosite
  • Pronto # 9608ES05X : FCSTM1 : When Bridge PDH with C3CD1 and STM1, Bridge SDH with C3CD2_SL06 new version combo box displays incorrect values
  • Pronto # 9609ES05X : When Bridge SDH SW=C3CD1 and STM, Bridge PDH SW= C3CD2SL_06 new version combo box displays wrong results
  • Pronto # 9628ES05X : Bridge PDH at C3CD1 and other cards at C3 level incompatibility is not getting detected
  • Pronto # 6557ESPE06 : SW Compatibility window does not display incompatible units if unit with newer SW is uninstalled
  • Pronto # 17352ESPE01: Software Upgrade on MetroSite is not successful, Bridge PDH not updated
  • Pronto # 9491ES05X : FCSTM1_EMA Alarms report mentions node version as Metrohub Manager C6 for FCSTM1 alarm report
  • Pronto # 9682ES05X : FCSTM1 Not able to modify Performance colletion timer in STM1 SDH PDH Channels dialogue
  • Pronto # 9793ES05X : US/MH: Manager crashes when imported .abs file (Dbus).
  • Pronto # 9640ES05X : Element Manager Shows all the Units as Uptodate In Ultasie when STM1 has C3.0 and below software - Online help text for FXC STM and compatability issue updated
  • Pronto # 9795ES05X : US/MH:Help is not present for Bridge-Measurement - Help button

The Element Manager changes in release 7.0 (Build 7.0.8) are:

Requirements Implemented

  • Migrated the Help from Win Help to chm format.
  • Look & Feel of the EM will be as per the look & Feel of the respective OS

Features Added

  • Windows Vista Support

 

Features Modified

  • None

Features removed

  • None

Bugs Fixed

  • None

 

The Element Manager changes in release 7.0 (build 7.0.9) are:

Requirements Implemented

  • “Nokia Siemens Networks” folder shall be in ‘Start’ menu instead of ‘Start->Programs’ menu.

Features Removed

  • None

Features Added

  • None

Features Modified

  • None

Bugs Fixed

  • None

Back to Contents



Known Issues

The following issues are known for this Element Manager version:

  • None yet

Back to Contents



Other Information

Product codes for some of the products:
 

Product

Code

LMP Cable

CS 72451.01 / T55270.01

SiteWizard 6 CD4.0 (via NOLS)

471919A.105

SiteWizard 6 CD4.0 (CD-ROM)

471918A.105

Pentium is a trademark of Intel Corporation.

Windows Vista, Windows 2003, Windows 2000 and Windows XP are registered trademarks of Microsoft Corporation.

Other products may be trademarks or registered trademarks of their respective manufacturers.

© 2009 Nokia Siemens Networks. All rights reserved.

Nokia Siemens Networks operates on a policy of continuous improvement. Therefore we reserve the right to make changes and improvements to any of the products described in this guide without prior notice.

Nokia Siemens Networks is not responsible for any loss of data, income or any consequential damage howsoever caused.
 

Back to Contents