RRI Manager C7.0
(Build 7.0.9)
Copyright © 2009 Nokia Siemens Networks. All
rights reserved.
Contents
Introduction
System Requirements
Compatibility
Installation
Uninstallation
Document Errata
Version History
Known Issues
Other Information
Introduction
This document provides some important
information about RRI Manager (referred to as "the Element Manager"
or "the EM" hereinafter). Please read this (as well as the documentation for the Elements
involved) through before using the Element Manager.
There is more detailed information also
in the online Help of the Element Manager.
This Element Manager is used for managing
the FXC RRI cards and connected outdoor units.
Back to Contents
System Requirements
In order to use the Element Manager, you
need the following:
- Operating System (English versions):
- Microsoft Windows 2000 Server
- Microsoft Windows XP Professional
- Microsoft Windows 2003 Server
- Microsoft Windows Vista
The
Element Manager does NOT officially support any other Windows Operating
Systems.
- An Intel Pentium compatible PC:
- Processor: min. 300 MHz (recommended 500 MHz or
more)
- Memory: according to installed operating system
(preferably the recommended amount)
- Monitor: min. SVGA with 800x600 resolution
(recommended 1024x768 resolution)
- Hard disk: 10 MB free space exclusively for the
Element Manager installation (recommended 25 MB)
- Pointing device: mouse, trackball, touchpad or
equivalent
- CD-ROM drive
- (local connection) 9-pin serial port in the PC
- (local connection) LMP cable (see more details
in section Other Information)
- (remote connection) Network adapter with
connection to DCN
- (optional) Windows compatible printer
Back to Contents
Compatibility
This Element Manager release is
compatible with the following:
|
Item
|
Product Version
|
HW Version
|
SW Version
|
|
FXC RRI Card
|
101 – 104
|
E55833.01 A0, A1, A2, B0
|
S55832.01
F0, G0
|
|
FXC RRI Card
|
105 – 109
|
E55833.01 C0, D1, E0
|
S55837.01 B0, C0,
D0, E0
|
|
MetroHopper Outdoor unit
|
-
|
-
|
C3.1, C3.2, C4.0
|
|
FlexiHopper Outdoor unit
|
-
|
-
|
C3.3.4, C3.4, C5.2.4, C5.3, FH6.6, FH6.7
|
|
FlexiHopperPlus Outdoor
unit
|
-
|
-
|
FHP2.6, FHP2.7
|
|
MetroHub Manager
|
-
|
-
|
C7.0 (build 7.0.9)
|
|
USBTS Hub Manager
|
-
|
-
|
C7.0 (build 7.0.9)
|
|
BTS Manager
|
-
|
-
|
CX6 CD2.0
|
|
GCS communication stack
|
-
|
-
|
4.2, 5.0, 6.0
|
|
NetAct
|
-
|
-
|
NetAct OSS4.1, NetAct OSS4.2
|
The Element Manager is a part of
SiteWizard 6 CD4.0.
Back to Contents
Installation
You can obtain the Element Manager
Through SiteWizard CD-ROM or you can download it via https://www.online.nokia.com/SWD/: Software Delivery > Operations Support Systems
> Element Management Products > SiteWizard.
To install the Element Manager, follow
the instructions of the SiteWizard installation program.
The installation program should start automatically when the CD-ROM is
inserted in the CD-ROM drive. If it does not start, run setup.exe from the
CD-ROM manually.
If you received the Element Manager
installation package as a compressed file (.zip), extract the zip file contents
into some temporary directory in your hard disk. Then run setup.exe from the
directory. After the installation is completed, you can delete the temporary
directory and its contents.
The Element Manager files are installed
into the directory you selected during the installation (referred to as
"Installation Directory").
The Element Manager startup (shortcut)
icon is added into the "Nokia Siemens Networks" folder.
The Element Manager executable
"FXCRRIMan.exe" is located in the Installation Directory.
To use connection services of the Element
manager, GCS communication service (as per the compatibility chart above) must
be installed.
Back to Contents
Uninstallation
To uninstall the Element Manager, follow
the normal Windows application uninstallation procedure (from the Control Panel
select Add/Remove Programs).
For more details, see the online Help of the Operating System.
NOTE:
If you have saved some extra files (logs, configurations, etc.) to the Element
Manager directory, those files and the directory will NOT be deleted. You need
to remove them by yourself.
Back to Contents
Document Errata
There are no significant documentation
updates.
Back to Contents
Version History
The Element Manager changes in release
2.1 are:
Features Removed
- Connecting to UltraSite BTS in stand-alone
mode.
- Q1 Int settings in Service Interface dialog
can't be modified.
Features Added
- FC RRI support.
- Loop Network topology support in Traffic
Manager.
- Commissioning Wizard-Monitoring Hop dialog: BER
values are read from indoor unit.
- Multiple selections in platform interface
settings.
- Node file commissioning now commissions also
radios.
- Popup menu in Equipment view supports
uninstallation of radios.
- Commissioning Wizard-Monitoring Hop dialog: BER
values are read from indoor unit.
Features Modified
- Changed reading of MetroHopper
RF Settings to use k-commands.
- Changed the MetroHopper
RF Settings -dialog so that after commissioning all settings of the page
are read again.
- Limits of Flexihopper settings are read from
outdoor unit.
- Send all menu command now sends only indoor
unit data.
- Changed detection of hop ready state in
commissioning.
- RRI manager stand-alone mode allowed only when
connected to MetroSite BTS.
- Q1 address in LMP connection displayed properly
in caption bar.
- FlexiHopper status in Monitoring
Hop dialog is changed to Ready/Not Ready.
- Commissioning of FlexiHopper
now sends all data to radio (Previously only identifications were sent).
The Element Manager changes in release
3.0 are:
Features Removed
- Removed Platform interfaces while working on EOCs, Loops, Priorities.
- Removed NWI-NMI support.
- Removed CC (Cross Connections) menu item from
the main menu and placed it as submenu under "Configuration"
item of the main menu.
- Master/Slave selection removed from Q1 Management->
Loop Protection dialog. All entries in this dialog will now be only of the
Slave type.
Features Added
- New CC UI, EDGE and EDAP support.
- Separate D-Bus allocation through embedded
Transmission menu.
- ROSE support & XML
- Network Topology support in Syncronization
dialog. Included support to store Network Topology settings in SCF file as
"TOPOLOGY_CHAIN" and "TOPOLOGY_LOOP".
- Compressed file SW download.
- Corrupted SW indication (Testing only).
- Default SWDL options.
- Loop Sync Status.
- TSO (MCB/LCB) bits handling in Synchronization
dialog.
- 2M CC creation when EOC and Sync Loop Control
Bits are added to node.
- Circuit Management dialog for TRUNET
parameters. The menu item 'Circuit Management...' under 'Configuration
calls this dialog.'
- When TRUNET is enabled,
in the sync priorities dialog, controls for priorities that were created
on PIF 12 will now be shown as disabled.
- When TRUNET is
enabled, then Loop Control Bits dialog will show any control bits that
were created on PIF 12 but they cannot be modified or deleted.
- When TRUNET is
enabled, then EOC dialog will show any EOCs
that were created on PIF 12 but they cannot be modified or deleted.
- When TRUNET is
enabled, then Loop Protections dialog will not show any loop protections
that were created on PIF 12.
Features Modified
- The Priority dialog now has a changed layout
and the Active source will now be shown as static text.
- Reading the New Unit Identifications and
changes to Unit Identifications page.
- "Send to indoor unit" functionality
so that CC banks are not activated or copied when EOCs
and sync loop bits are sent from node file to device.
- Date and Time display in all identification
dialogs. Now these entries are no more Edit boxes but they will call a
date-time control. So empty entries are disallowed.
- RSWDL enhancements(LCH 10 usage).
- SWDL activation changes, polling logic changed.
- RSWDL enhancements to OU to handle GCS timeout
problems.
- RSWDL Harmonization.
The Element Manager changes in release
3.1 are:
Features Added
- Fault recovery/re-transmission support during
SW download.
- Manager read improvement.
- SWDL interruption/CRC error info.
- 24-hour support for SWDL.
- New GUI for SWDL Management dialog.
- "Saving Node File Improvement"
implemented.
- "Conversion of node file to binary"
implemented.
- Support for logical channel 8 for remote SWDL
to FXC-RRI card and OUs.
- Support for OU SW code check before software
download to OUs.
- Support for 2M CC creation before send to
indoor unit.
- Support to Restore factory settings to node
before send to indoor unit.
- Support for 50 MHz channel spacing for Metrohopper.
- Support for Hot Standby (HSB).
- Support for Far-End Management in Embedded HubManager mode.
- Support for Fading Margin Measurement.
- Support for Circuit management support in file
mode.
- Support for TFTP checksum during software
download.
- Support for HW resets using one command.
- Support for Factory resets using one command.
- New platform interface page in "Unit
Settings" dialog implemented.
- Support for CPU Reset Counter in Statistics
dialog.
- Support for Remote Transmission Manager in
Remote MMI.
- Support for Direct FlexBus
commissioning during XML commissioning by HubManagers.
- Support for High Density Radio.
- Support for new file extensions (.nod, .xcs,
.tmn).
- centering of Interface Loops dialog in the
application main window.
Features Modified
- Maintenance menu enhancement feature,
harmonized the SW management dialogs with E1/T1 Manager.
- HW Reset support to unit managers, also
harmonized and enhanced the existing Factory resets dialog.
- Support for Manager Options is taken into use
from platform.
- Support for Alarms view into use from platform
with the new Alarms view provided by platform.
- Support for Q1 Management dialog and
Synchronization dialog is taken into use from platform.
- Support for TRUNET taken into use from
platform.
The Element Manager changes in release
3.1-1 are:
Bugs Fixed
- Pronto# 2116ES11P - When opening the radio
setting window of FlexiHopper Plus in FXC RRI
card manager the first time, it doesn't show the current setting. After
changing it and opening the window again, the current setting is shown.
- Pronto# 2116ES11P - The manager doesn't show
which bandwidth is in use for the FlexiHopper
Plus radio.
- Pronto# 2649ES10P - Message box strings needs
to changed.
- Pronto# 2382ES08P - Bandwidth
setting of FlexiHopper Plus not read in Radio
wizard. Bandwidth setting cannot be set in Wizard.
- Pronto# 2597ES11P - Commissioning with radio
wizard: only full bandwidth can be selected, not possible to select
interleave status (or fading margin, ALCQ set point).
- Pronto# 2117ES11P - The Parameter
names for the modulation type in FlexiHopper
plus are different than in Hopper Manager (currently Full Bandwidth, Half
Bandwidth; correct 4-state, 16-state).
- Pronto# 2755ES10P - RRI man has no support for
compressed (pkz) OU file selection.
- Pronto# 2679ES10P - Interleave Status should be
disabled with empty value if 16-state is active. Interleave status not to
be sent to radio.
- Pronto# 2590ES11P - In HSB far end view manager
shows random alarms for far end.
- Pronto# 2597ES11P - Commissioning with radio
wizard: only full bandwidth can be selected, not possible to select
interleave status (or fading margin, ALCQ set point).
- Pronto# 2116ES11P - Configuration report in Hubman still shows "Full" or
"Half" for Modulation setting.
- Pronto# 2649ES10P - In RadioWizard
there is still possible to get odd combinations between modulation and
interleave status.
- Pronto# 2755ES10P - *.PKZ file download support
for Flexihopper Plus.
- Pronto# 2597ES11P - Display of Interleave staus in commissioning report and Fading Margin button
is enabled when there is no OU connected.
- Pronto# 2649ES10P - Setting new modulation from
the OU settings dialog, doesn’t change the
modulation if capacity has to be changed at the same time.
The Element Manager changes in release
3.2 (build 3.2.10) are:
Features Added
- It shall be possible to calibrate the
free-run PDH node clock by management action, without the need to be locally
present or to use an external measurement device.
- Q1 scriptor
tool can be launched from the manager.
- D-BUS Support for MetroHub if RRI is
DNCU - Disabling PIF 15
Features Modified
- New Sync functionality.
- SW Download File type options changed.
- It's possible to enter "," and
"." in user notes with ITN C2.2 node SW.
- Unit software download - Software ID and
version modification in EM. If inactive bank SW is 2.2 or higher and
active bank SW is 2.1 or less.
Bugs Fixed
- Pronto# 1-21087249 - NTI416:Wind FXC RRI HSB.
- Pronto# 3368ES08P - RRI Manager Interface
counter reset in statistics resets also CPU counter.
- Pronto# 3368ES08P - The used LMP speed and adress are not restored after Node factory default is
given with stand alone RRI manager.
The Element Manager changes in release
3.3 (build 3.3.4) are:
Features Added
- It shall be possible to install/delete licences to licencing
compatible units. Currently only Flexihopperplus
units support licensable features.
- ALCQ and ATPC support added to Flexihopper units.
- Scrambling polynom
support added to Flexihopper units.
- BER change.The EM
uses K command to get the BER value instead of the m command. BER is
changed to FEC (Forward Error Correction) everywhere in the UI.
- Help Updated.
Bugs Fixed
- Prontos# 1-43467532 & 8704ES11P: Loss of
TRXSIG channel when expanding TRXSIG from 16 to 32kbit/s.
- Pronto# 10257ES11P: Cingular case with
launching RRI and E1T1 manager.
- Pronto# 9249ES11P: Max TX Power for FH+ not
successfully sent.
- Pronto# 10711ES11P: Switch from 4-state to
16-state is possible although Max TX power value is out of range.
- Pronto# 10779ES11P: eFeature:
In HSB mode RRI Radio Wizard don't check or install license for OU2.
- Pronto# 10651ES11P: Missing alarm desriptions for elicensing
related alarms.
- Pronto# 10714ES11P: Incorrect warning is
displayed when negative TX power value is set while 4-state modulation is
used.
- Pronto# 8259ES11P: TX power setting range wrong
when changing between 4 and 16-state in FH+.
- Pronto# 10495ES11P: When Flexihopper+ radio is
connected, functional error comes during opening configuration report.
- Pronto# 10497ES11P: ALCQ/ATPC set point has
incorrect value in configuration report.
- Pronto# 10562ES11P: Problem with Fading Margin
Measurement in RRI Manager.
- Pronto# 10782ES11P: eFeature:
In RRIMan Radio Wizard it's not possible to
return to license install window.
- Pronto# 13249ES09P:eFeature: RRIMan doesn't give any error message when trying to
activate OU SW when downgrading is not allowed.
- Pronto# 10896ES11P: Chosen scrambler polynome is missing in commissioning report.
- Pronto# 10766ES11P: Alarm location '1-RRI SB73'
not very helpful.
- Pronto# 10809ES11P: FXC RRI Flexbus BER
measurement named wrong in RRIMan.
- Pronto# 8160ES10P: Radio commisssioning
of FHPlus: Tx power
not set.
The Element Manager changes in release
4.0 (build 4.0.15) are:
Features Added
Features Modified
- COM port change - Number of selectable COM
ports should be more than 4.
Requirements implemented
- ITN_SysRqt0847 : Space diversity.
- ITN_SysRqt0916 : Configurable number of
D-busses.
- ITN_SysRqt0764 : SW to be downloaded matches
with the unit type prior to downloading it.
- ITN_SysRqt0906 : Default settings to be same
with Node SW.
- ITN_SysRqt0808 : Support of xml formatted files
for backup of configuration data.
- ITN_SysRqt0826 : G.826 OU PM data history
records.
- ITN_SysRqt0778 : RX level min/max performance
records.
- ITN_SysRqt0774 : G.826 PM data history records
for 2M platform interfaces on FXC RRI.
- ITN_SysRqt0937 : MetroHopper
XL support for Factory defaults to OU.
- ITN_SysRqt0825 : Reset of "Incoming signal
level incorrect" alarm.
- ITN_SysRqt0835 : Backup of OU settings to IU
(manual) - FIU.
- ITN_SysRqt0836 : Backup of OU settings to IU
(automatic) - FIU.
- ITN_SysRqt0837 : Restore of OU settings from IU
- FIU.
- ITN_SysRqt0943 : EM hides cryptic part of
Circuit Manager created CC.
- ITN_SysRqt0951 : Support of Site ID as string
and using Site ID to select node instead of Site Name.
- ITN_SysRqt0880 : User access levels to Element
Managers.
- ITN_SysRqt0940 : Addition, modification support
for nx8k CC.
- ITN_SysRqt0842 : G.826 statistics FB & PM
records (via EM).
- ITN_SysRqt0957 : E-Licensing support for FB
Capacity.
- ITN_SysRqt0910 : same pilot bit within one node
for different protected bi-directional cross-connects.
- Retransmission support while downloading a node
software.
- New structures related to BTS Manager added.
- EM setups should clean the registry during
uninstallation.
Bugs Fixed
- Pronto# 10496ES11P : Refresh all icon
has different name in toolbar than in connection menu.
- Pronto# 10654ES11P :
Master/Slave-setting (MetroHopper) is not
correctly stored in node file.
- Pronto# 10827ES11P : MetroHopper
link down after checking/unchecking 'Active
Synchronization Master'.
- Pronto# 2152ES11P : The Metrohopper Hop End is always saved as Slave and
Transmission Frequency as 0 into XML file when online.
- Pronto# 8425ES11P : Differences between RRIMan offline 'Alarm properties list' and specified
values.
- Pronto# 8923ES11P : Help button is
missing.
- Pronto# 8962ES11P : FlexiHopperPlus
16-state-mode tries with 4x2Mbit capacity with FXC RRI.
- Pronto# 9231ES11P : In RRIMan Radio Wizard Commissioning report MH HopId is displayed as hexadecimal.
- Pronto# 11560ES11P : Manager crashes
when saving in file mode.
- Pronto# 11564ES11P : Can't open files,
which are made by older managers.
- Pronto# 11665ES11P : Problems with
platform interface measurements dialog.
- Pronto # 9268ES11P : Trunet settings not
stored in configuration file.
- Pronto # 9164ES11P : Traffic cut (1s
AIS) when adding/removing a second priority to PDH synchronization list.
- Pronto # 11103ES11P : NodeManager hanging after changing OperationMode
while Flexbus Power is off.
- Pronto # 2901ES43 : EOC-dialog-shows no
available e1b-channels.
- Pronto # 11601ES11P : RRI Manager does
not save the set Manager options anymore on exit.
- Pronto # 11562ES11P : Timeslot
monitoring doesn't work.
- Pronto # 11152ES11P : FMM warnbox is displayed twice.
- Pronto # 9166ES11P : Loss of frame
alignment (2M) when switching from Sync Input to another synchronization
source.
- Pronto # 8058ES11P : Inactive XC bank
does not empty after HW Reset when Bridge in node.
- Pronto # 11123ES11P : Strange values
from Radio Wizard in FlexiHopper settings
window.
- Pronto # 10815ES11P : In RRIMan Radio Wizard Commissioning report MH M/S
displayed as 'SUPERMASTER' is confusing.
- Pronto # 11318ES11P : Manager Options
'Save Setting on Exit' not working.
- Pronto # 10657ES11P : FMM values
displayed cannot be assigned to a specific measurement.
- Pronto # 8654ES10P : Tx
frequency limits in RRI commissioning wizard are incorrect.
- Pronto # 8301ES11P : Interleave Status
setting missing for MH in RRIMan Radio Wizard.
- Pronto # 11073ES11P : There is wrong
information in help.
- Pronto # 2589ES11P : The FMM display
fields in the ITN Managers lists measurement results inconsequently.
- Pronto # 5692ES11P : Severity state
change of alarms - handled differently on different cards / different
equipment.
- Pronto # 2846ES08P : MHMan
allows interfaces with pending CCs to be selected in timeslot monitoring
even if they can't be read.
- Pronto # 10580ES11P : RRI Manager
displays only 2 values when doing Fading Margin Maeasurement.
- Pronto # 6577ES11P : Incorrect Alarm
& LED visualization.
- Pronto # 3076ES08P : Limitations in
Configuration Report.
- Pronto # 9154ES11P : Even though
Settings is selected for one OU the info os read
from both radios.
- Pronto # 2924ES08P : Inconsistancy
with FMM buttons in Radio wizard hop status detection and reporting in
single mode.
- Pronto # 2560ES08P : When creating a 2M
bypass CC, the manager doesn´t detect if channel
1 is already used by synchronization list.
- Pronto # 12418ES11P : RRI DBus settings in MS and US cabinet doesn't work.
- Pronto # 9103ES10P : FXC RRI - Q1 - When
reading the RRI Unit Settings, the NM reads the wrong PIF for D-Bus.
- Pronto # 10701ES11P : FH plus seems to
do extra HW reset when modulation change is forced by selecting 2x2M or
4x2M FB capacity.
- Pronto # 11874ES11P : cancellation of
RRI card software download leads to wrong SW indication in both banks.
- Pronto # 4374ES10P : FMM fails with HSB
(RRIC and RRI).
- Pronto # 8660ES10P : SW download is slow
when FHP is used with FXC-RRI.
- Pronto # 7748ES11P : Problems with
remote SW activation on RRI cards.
- Pronto # 11495ES11P : FMM measurement
for HSB link with FH+ does not work with newer version of radio SW (B4).
- Pronto # 2924ES08P : Inconsistancy
with FMM buttons in Radio wizard hop status detection and reporting in
single mode.
- Pronto # 4362ES10P : FMM possible with
ALC switched on.
- Pronto
# 12948ES11P : GUI: Q1-Management dialogs
- Pronto # 1-54191373 : Combined 32K
OMU&TRXSIG on TCH.
- Pronto # 9422ES11P : CC-import and PIF15
reservation if chaining enabled.
- Pronto # 11270ES08P : CC wizard keyboard
keys not same as previous releases.
- Pronto # 2741ES11P : It's not possible
to make CC with Tab and arrow keys.
- Pronto # 12937ES11P : Commissioning
report help button is missing.
- Pronto # 12898ES11P : Help button is
missing from CC properties dialog.
- Pronto # 12946ES11P : Extra space
character in splash screen.
- Pronto # 14886ES09P : Saving node
settings with HubMan / USBTSHubMan fails.
- Pronto # 2376ES11P : & Symbol not
displayed in CC Bank.
- Pronto # P234602 : Time stamp in the top
of the alarm-view doesn't update when Refresh All is pressed.
- Pronto # 9994ES11P : Q1 Ext connection
does not recover after chainging speed.
- Pronto # 9036ES11P : MetroHub Manager
Alarm Window Locked.
- Pronto # 10819ES11P : RRIMan doesn't support use of old FH and FHP
(T55xxx.xx) in HSB configuration.
- Installation Problem related to GCS -
Failure message changed.
- Frequency step field to be made ready
only static text with 1Khz.
- Pronto # 13571ES11P : PM records not
shown correctly for FB IF.
- Pronto # 2160ES11P : The Fading Margin
Measurement does not always work when used from the Commissioning wizard
or the Outdoor Unit dialog if FlexiHopper plus
radios are used.
- Pronto # 12941ES11P : FMM in HSB not
done correctly in element manager.
- Pronto # 13570ES11P : Rx level records,
time is wrong.
- Pronto # 8303ES11P : Problems with FM
measurement in RRIMan when FH+, 16-state, single
mode.
- Pronto # 13555ES11P : Help problems with
RRI manager.
- Pronto # 9170ES10P : FXC RRI - LMP does
not connect after Q1ext connection.
- Pronto # 9149ES11P : 'An unsupported
operation was attempted' message during remote connection.
- Pronto # 2588ES11P : In MetroHub HubMan
FMM result is sometimes shown as 298 even though it should be sometihng like 0,1.
- Pronto # 6020ES08P : RRI Node Manager's
UI is hanging.
- Pronto # 13722ES11P : Faulty data
structure when sending Circuit Managent data -
First char of site name overwritten.
- Pronto # 13702ES11P : FMM with
attenuated radio hop returns wrong response in MHB.
- Pronto # 13703ES11P : FMM in MHB
Commissioning Wizard is NOK if far end radio FE changes.
- Pronto # 13731ES11P : Circuit-related
cross-connections not shown as pending in EM's cross-connection window.
- Pronto # 13832ES11P : Deleting MCB/LCB
´s also removes the 2M CC´s from the payload
cross connections in the active CC Bank.
- Pronto # 13896ES11P : Creating CC gives
error message.
- Pronto # 13898ES11P : Help button and
help text is missing from conflicting CC's window.
- Pronto # 13962ES11P : The pending CC ´s
and semi pending CC´s are not shown with the
correct font and colout if a FXC unit is ripped
out.
- Pronto # 14039ES11P : RRI CC NM
- Creating a cross-connection with RRI generates an error message always.
- Pronto # 14523ES08P : Fading margin
measurement problem with old FXC RRI.
- Pronto # 13955ES11P : Far end management
(in element manager) in case of HSB does work.
- Pronto # 14038ES11P : RRI PM NM -
Flexbus Statistic History shows EB in wrong scale.
- Pronto # 13686ES11P : interleaver status of OU not visible in EM in case of
HSB with SD.
- Pronto # 14468ES11P : FMM result added
for far end even if connection cut.
- Pronto # 14156ES11P : FMM far end OU
wrong in Radio Wizard report.
- Pronto # 14235ES11P : RRIMan measurements do not allow FEC Corr. rate measurement to be selected for FHP SW D6.
- Pronto # 14298ES11P : Offline changing
of Operation mode to HSB with RRIMan can cause FB
capacity mismatch.
- Pronto # 14400ES11P : Pressing enter in RRIMan OU User Notes field updates installation time
and date.
- Pronto # 14401ES11P : Too difficult to
enter RRIMan OU SB name editing mode.
- Pronto # 14466ES11P : Radio Wizard
report displays only FMM result for one hop.
- Pronto # 14470ES11P : If radio hop is
attenuated for some time to more than BER3 during FMM result displayed
wrong.
- Pronto # 14803ES11P : Wrong version info
in Print review.
- Pronto # 10539ES10P : Change in CC type
causes a traffic cut.
- Pronto # 9164ES11P : Traffic cut (1s
AIS) when adding/removing a second priority to PDH synchronization list.
- Pronto # 15047ES11P : UALC feature does
not prohibit remote modification of system although feature installed and
enabled.
- Pronto # 15042ES11P : Payload
cross-connection modified and traffic cut after synchronization source was
removed or modified.
- Pronto # 14141ES11P : Frequency and
power limits not always displayed in RRIMan.
- Pronto # 15027ES11P : In FH Statistics
History the newest records are reported as oldest.
- Pronto # 15026ES11P : In FlexBus Statistics History the newest records are
reported as oldest.
- Pronto # 14978ES11P : no statistic
history data for HSB is shown.
- Pronto # 15025ES11P : FlexBus Statistics History NOK in HSB mode.
- Pronto # 8983ES11P : Connection type,
speed and address is not shown in the status bar of the Standalone RRIMan when connected remotely.
- Pronto # 15154ES11P : A unnecessary 2M
Payload CC is left in the CC bank if a RRI sync source is edited from one
channel to another channel with a Remote connection to a MSBTS.
- Pronto # 15173ES11P : When trying to add
a MCB/LCB remotely with a standalone RRI Manager, the RRImanager
disappears as soon as Apply is pressed.
- Pronto # 15210ES11P : A 2M payload CC is
left in the active CC bank after a MCB/LCB is deleted from a FXC RRI.
- Pronto # 15169ES11P : "Fading
margin measurements are not visible in commissioning report ".
- Pronto # 15320ES11P : RRI manager starts
in read-only mode in local connection if it's started via BTS manager.
- Pronto # 14826ES11P :
"Configuration of Trunet probably caused SiteName
being deleted in identifications".
- Pronto # 15354ES11P : Pressing enter in RRIMan OU User Notes field causes all text after this
to be lost.
- Pronto # 15621ES11P : PIF Statistics History
not selectable in RRIMan when HSB mode in use.
- Pronto # 15408ES11P : EM shows wrong
FE-info incase OU is uninstalled.
- Pronto # 15576ES11P : CrossConnection Import/Export fails with FXCRRI in
MetroSite and RRI manager 4.0.9.
- Pronto # 15683ES11P : fxcrriman.exe
Application Error.
- Pronto # 15643ES11P : When a sync
priority is deleted with local LMP connection, the 2M CC is removed from
the payload CC in the same channel in the active CC bank.
- Pronto # 15869ES11P : Not possible to
set 16-state modulation on for FHP with RRIMan.
- Pronto # 14542ES11P : FMM result not
added to MHB Commissioning Report for OU connected to old RRI.
The Element Manager changes in release
4.1 (build 4.1.2) are:
Features Added
Features Modified
Requirements implemented
- ITN_SysRqt0962 : Harmonized PM data view
of E1/T1, STM-1 and RRI
- ITN_SysRqt0963 : Reduce configuration
upload and download times
- ITN_SysRqt0863 : RRI-FMM dialog
- ITN_SysRqt0922 : A user shall be
informed if there are inconsistencies between the cross-connection data
represented towards the user via Element Manager and the actual
cross-connection data at the ITN/FC STM node. If a inconsistency occured user shall be able to upload the
cross-connection data from the ITN/FC STM node to re-establish consistency
- ITN_SysRqt0829 : Hub manager shall
support "Yellow alarm" for OU miss-configuration indication in
far-end view
Bugs Fixed
- Pronto # 15440ES11P : Node Managers do
not fullfil ITN_SysRqt0951
- Pronto # 14735ES11P : Site Identifier
restricted to alphanumerical strings
- Pronto # 15171ES11P : RRIMan Statistics History max block limit wrong for
FHP
- Pronto # 15106ES11P : RRIMan Statistics History max block limit wrong for FB
- Pronto # 15149ES11P : Dbus12 and 13 settings
with RRI able to be changed with misleading warning
- Pronto # 18377ES11P : D-Bus usage
settings don't work properly
The Element Manager changes in release
5.0 (build 5.0.11) are:
Features Added
Features Modified
Requirements implemented
- ITN_SysRqt0787 : Polling of Alarms in a
separate thread.
- ITN_SysRqt0967 : Full Loop Wizard(Undo
the code for LoopWizard).Pilotbits
check box functionality should be developed.
- ITN_SysRqt0922 : A user shall be
informed if there are inconsistencies between the cross-connection data
represented towards the user via Element Manager and the actual
cross-connection data at the ITN/FC STM node. If a inconsistency occured user shall be able to upload the
cross-connection data from the ITN/FC STM node to re-establish
consistency.
- ITN_SysRqt0309 : Remote change of Q1 NE
address and baudrate.
- ITN_SysRqt0775 : The ITN element manager
shall be able to display the BER infinity FEC corr.
rate counters from the outdoor units connected to a FXC RRI unit. It shall
be possible to reset the counter.(notice, requirement text changed, needs
still review with CT although feedback already received from Antti, can be
placed under measurements, probably already implemented, needs only a name
change from FEC to FEC corr. rate).
- ITN_SysRqt0863 : Alignment of FMM GUI.
- ITN_SysRqt0773 : Save the PM data in a
text file for further analysis.
- ITN_SysRqt0830 : Button to change
threshold for incoming signal level incorrect alarm.
- ITN_SysRqt0866 : Protection switching
schemes => Lazy switchover support.
- ITN_SysRqt0969 : conflicting settings
dialog.
- FXC_SysRqt_0407: RAML 2.1 support
limited to updation of
"AdaptationVersionMajor".
- ITN_SysRqt0972 : Error handling.
- ITN_SysRqt0975 : Alarm Rationalization.
- ITN_SysRqt0977 : Node status report.
- ITN_SysRqt0978 : Part of Node Status
report(ITN_SysRqt0977) : generation of the customer report from one
dialog, excluding ability to cancel.
- ITN_SysRqt0978 : Part of Node Status
report (ITN_SysRqt0977)and same as above : representing only the ability
to cancel generation of node status report.
- COMITN_xxx : Change of Version
number of the EM to C5. Internal version to be changed to 5.0
Bugs Fixed
- Pronto # 18464ES11P : FMM doesn't work.
- Pronto # 18463ES11P : Manager crashed
when opening far-end settings.
- Pronto # 18493ES11P : Measurements of
Far End Not Available.
- Pronto # 18496ES11P : FEM - Hub Manager
crashes after click on FarEnd Identification- UnitId.
- Pronto # 18500ES11P : Far End Outdoor
Unit Settings displayed wrongly as Protected when Operating on single
mode.
- Pronto # 18517ES11P : Far End Outdoor
Unit Settings doesn't work on HSB mode. MetroHub Manager Crashes.
- Pronto # 18514ES11P : FEM - None of the
Menu options working with FIU on FarEnd and RRI on Near End.
- Pronto # 18510ES11P : Warning Message
Incomplete while changing Far End Outdoor Unit Modulation.
- Pronto # 18628ES11P : Q1 loop protection
is not deleted by EM.
- Pronto # 18542ES11P : FEM - FarEnd
Management support is NOT available on the MetroSite.
- Pronto # 15237ES11P : FMM-dialog does
not show actual value after opening.
- Pronto # 18739ES11P : No 15-min and
24-hour performance data for 2M platform interfaces available in RRI
Manager standalone mode when using old RRI HW.
- Pronto # 18396ES11P : RRI FB(Flexbus)
message window for 'statistics history' menu is misleading.
- Pronto # 19092ES11P : Disabling D-Bus
may cause misconfiguration occurs when enabling
Platform Interfaces (PIF).
- Pronto # 11991ES10P : FXCRRIMan: OU replacement in HSB configuration fails
if OU's modulation setting changed.
- Pronto # 16004ES11P : RRI manager is
crashing if modulation mode of Flexihopper OU with license file is
changed.
- Pronto # 18500ES11P : Far End Outdoor
Unit Settings displayed wrongly as Protected when operating on single
mode.
- Pronto # 16093ES11P : RRIManager: missing alarm activation times.
- Pronto # 19218ES11P : FarEnd related
menus are disabled after send to indoor unit operation.
- Pronto # 18982ES11P : Unit Software of
RRI Card is displayed incorrect.
- Pronto # 15685ES11P : RRIMan displays wrong error messages when there is no
FMM result available in OU.
- Pronto # 15446ES11P : Not possible to
select Protected hop BER in RRI Measurement window.
- Pronto # 15554ES11P : RRIMan doesn't notify correctly when trying to connect
to the wrong cabinet.
- Pronto # 19083ES11P : RRI 2M control CC
can be removed from CC dialog window.
- Pronto # 19084ES11P : RRI 2M CCs are not
created after default sync. priority is set.
- Pronto # 19663ES11P : Changes to the
Near End OU are not applied to the Far End OU causing a break in the Hop.
- Pronto # 19672ES11P : FarEnd Statistics
with FIU as far end does not show stats for OU.
- Pronto # 19687ES11P : Metrohub crashes with far end measurements monitoring
ON .
- Pronto # 19702ES11P : Far End OU label
wrongly displayed on Performance Monitoring Window.
- Pronto # 15164ES11P : D12 & D13 are
available in D-bus after they are disabled from unit settings.
- Pronto # 17100ES11P : Export of alarm
history in file contains only deactivation dates, activations dates are
missing.
- Pronto # 15592ES11P : Changing the Q1
address or speed is not possible with a remote connection.
- Pronto # 1-97391385 : Disabled Q1 port
settings.
- Pronto # 19661ES11P : Inconsistencies in
Far End 'Measurements' view with FIU on the far end.
- Pronto # 20014ES11P : Element manager
hangs if refresh all is pressed.
- Pronto # 19776ES11P : On HSB Mode, wrong
Identifications of far end OU opens with FIU19(E) as far end.
- Pronto # 19792ES11P : On HSB Mode with
FIU19E as far end, changes of far end OU settings doesn't work.
- Pronto # 19901ES11P : With HSB Mode,
Changes of OU Settings switches the OU to 'Forced control on'.
- Pronto # 19961ES11P : DBus 13 doesn't work.
- Pronto # 19660ES11P : FarEnd Statistics
data shows negative values, this is NOK.
- Pronto # 9120ES11P : Incorrect
information in status bar after send to indoor unit.
- Pronto # 15498ES11P : Scrambler
selection missing if scrambler different in OU1 and OU2 when switching to
HSB mode.
- Pronto # 20261ES11P : SB Number
displayed for Location of Far end alarm with FIU 19 as Far end.
- Pronto # 20395ES11P : Can not modify the
new EOC via remote connection.
- Pronto # 15687ES11P : CC test fails when
OU TX
power off.
- Pronto # 16726ES08P : USBTS: Q1
2400bit/s problem in slave RRI-card.
- Pronto # 19187ES11P : Unit settings of
RRI card are not changed without any error message, when modifying takes
several minutes.
- Pronto # 20770ES11P : FEM view displays OUs in not correct order.
- Pronto # 20262ES11P : Structure and
Location of Far end alarm is not displayed as specified in specification
document.
- Pronto # 19482ES11P : Statistics History
15mins records for RRI displayed incorrect.
- Pronto # 20530ES11P : Sync Priority is
changed after activating inactive CC bank.
- Pronto # 19806ES11P : EDAP modification
failed on MetroSite.
- Pronto # 19673ES11P : 'Refresh All'
Doesn't refresh Far End View.
- Pronto # 14629ES11P : All FlexiHopper plus alarms are not listed correctly by
RRI manager in offline mode.
- Pronto # 20766ES11P : Set PDH Node to
factory defaults command is not sent by nodemanager
in some cases.
- Pronto # 15741ES11P : When creating a
MCB/LCB the manager does not check if the FB hannel
is already reserved by a 2M bypass CC.
- Pronto # 21152ES11P : Text missprinted in Action section of enhance Error
Handling.
- Pronto # 21250ES11P : Pending and
blocked cross-connection information is missing from CC-view.
- Pronto # 20982ES11P : EM does not allow
to reconfigure the Sync settings in one go.
- Pronto # 16028ES11P : Hub Manager -
Restore factory defaults for Metro Hopper XL stops at 38%.
- Pronto # 21166ES11P : Display of actual
cross-connection status information doesn't work in RRI-standalone.
- Pronto # 20530ES11P : Sync Priority is
changed after activating inactive CC bank.
- Pronto # 20893ES11P : Alarm suppressions
in ITN C3 CD1.
- Pronto # 20892ES11P : Functional error
messages when opening alarm properties in RRI-standalone.
- Pronto # 20831ES11P : Far End OU1
Settings are displayed with label as OU2.
- Pronto # 31728ES09P : It is possible to
change Operation Mode in read only mode.
- Pronto # 4992C01 : Far End Unit Software
window doesnot open, it gives error.
- Pronto # 21473ES11P : The 'incoming
signal level incorrect' -alarm thresholds not saved in FH+ and not
configurable in metrohopper.
- Pronto # 19808ES11P : Setting Window dataches itself from the Main window in the RRI
Manager.
- Pronto # 31545ES09P : FarEnd OU settings
helps are not working.
- Pronto # 31730ES09P : Configuration
report doesn't open in file mode.
- Pronto # 5117C01 : Error message is not
displayed when connection is lost and Unit settings of RRI are opened.
- Pronto # 21792ES11P : Wrong help file
opened in Ultrasite.
- Pronto # 5223C01 : Metrohub
manager crashes while accessing the Outdoor unit 2 settings.
- Pronto # 22062ES11P : UltraSite Hub
Manager crashes when accesing OU Settings.
- Pronto # 22119ES11P : FarEndMeasurement not done with MS BTS (RRI Manager
5.0.7) and MetroHopper as FE radio.
- Pronto # 21869ES11P : slightly different
naming conventions for PM history export files.
- Pronto # 19901ES11P : With HSB Mode,
Changes of OU Settings switches the OU to 'Forced control on'.
- Pronto # 21845ES11P : Changing the
interleave status of a MetroHopper Link cuts of
the RadioLink continuously.
- Pronto # 21429ES11P : Signal lost for
one minute when switching OU tx-power back on in
HSB configuration.
- Pronto # 21666ES11P : USBTS EM:
Inconsistency between graphical view and list view of Cross Connections.
- Pronto # 19220ES11P : Restore of backup
settings failed.
- Pronto # 21650ES11P : Problem at
creation of Uni_Directional CC in FC-STM1 EM.
- Pronto # 21793ES11P : Non-functioning
helps when commissioning Metrosite.
- Pronto # 21819ES11P : TX frequency
change of OU via FEM doesn´t work.
- Pronto # 20274ES11P : Error in
CC-overview dialog.
- Pronto # 22237ES11P : EM crashes when
pressing additional settings button.
- Pronto # 34017ES09P : Company name
incorrect in splash screen.
- Pronto # 22249ES11P : Near end Radio
frequency is not changed when changing several settings at once.
- Pronto # 22307ES11P : Protecting ABIS on
SDH interface is shown as CHAIN in Traffic Manager.Necessary
Information Missing.
- Pronto # 22383ES11P : Apply button does
not get active, when TX Max Power of Far-End OU is modified.
- Pronto # 22385ES11P : If OU Far End Identification
User Notes contains a comma (,), user note is not stored in Radio (Far End
Radio connected to FIFA).
- Pronto # 22398ES11P : Frequency change
of HSB Link between UltraSite and FIFA does fail, when it’s
done with Far End Management of ITN Manager.
- Pronto # 11991ES10P : OU replacement in
HSB configuration fails if OU's modulation
setting changed.
The
Element Manager changes in release 6.0 (build 6.0.9) are:
Features Added
Features Modified
Requirements implemented
- C3CD2_2 : Automatic timeslot monitoring
refresh.
- C3CD2_1 : Measurement/Display of
internal +5V/-5V
- C3CD2_21 : Reduce remote communication
time
- C3CD2_28 : Resource conflict checking
- C3CD2_14 : It shall be possible to
switch all XCs of the node with one command
- C3CD2_26 : Alarm Rationalization (phase
2)
- C3CD2_23 : Improvement of alarm logging
file
- C3CD2_25 : MWR far end equipment view
with MetroSite BTS
- C3CD2_12 : Re-branding UI to Nokia
Siemens Networks style
- C3CD2_5 : A new Unit should enable to
upgrade a complete node to the new SW status
Bugs Fixed
- Pronto # 15577ES11P : FB2 is visible
even HSB is 'on'
- Pronto # 5327C01 : Saving of the PM data
is not aborted in case of interruption in management connection
- Pronto # 5836C02 : Softkeys
are not working properly in dialogues of Metrohub
manager
- Pronto # 5831C02 : Softkeys
are not working in Synchronization, traffic Manager, configuration report
dialogues
- Pronto # 5832C02 : Missing help in
"Help-Help Topics-Contents" dialogue
- Pronto # 5830C02 : Softkeys
are not working for menu in FXC RRI, FXC E1T1, FXC STM1 manager
- Pronto # 22466ES11P : After a software
download to a radio is aborted the selection of the alarm window results
in an 'Could not sent command'
- Pronto # 8901ES05X : Links under help
are not working for RRI manager
- Pronto # 22282ES11P : FxcRRImanager-Changing FarEnd
identifications does not work correctly with NearEnd
RRI in MetroHub and FarEnd FIFA
- Pronto # 22246ES11P : Modification of
8*64k CC to 2M CC not possible. Deleting 8*64k CC and creating 2M CC
works.
- Pronto # 31743ES09P : Corrupted CC
modifying doesn't work correctly.
- Pronto # 8878ES05X : Controls in TS
Monitoring do not get enabled when same TP is used in an active as well as
in a pending CC
- Pronto # 22497ES11P : FarEndManagement with MetroHubManager
5.0.9: reset interface statistics clears also unit reset counters
- Pronto # 22491ES11P : Changing the
modulation and tx frequency simultaneously from
far-end settings leaves the tx frequency not set
- Pronto # 6223C02 : E1T1 Delete Signal
for OMUSIGTRXSIG1 is not working properly
- Pronto # 6198C02 : US,MH:Manager
is not able to handle conflict for TRXSIG on TCH
- Pronto # 14052ESPE01: The +5/-5V unit
measurement values are displayed incorrectly in the node status report.
- Pronto # 6186C02 : E1T1,RRI:Disabled OK
button on RRI&E1T1 MGR in file mode
- Pronto # 18998ES11P : k-command
mentioned under Details in warning box
- Pronto # 9261ES05X : RRI:'Could
not send command' error dialogue is not seen when Clear Alarm History
command fails
- Pronto # 9318ES05X : TRX numbers used in
EDAP are displayed under the title 'Traffic Manager' in Traffic Manager
window
- Pronto # 9411ES05X : BTS Manager hangs
when attempted to delete multiple conflicts
- Pronto # 6043ESPE06 : Cross connection
mismatch window occurs unexpected
- Pronto # PR9471ES05X: MH US_EMA Manager
crashes when deleting a conflicting signal from a imported file
- Pronto # 9482ES05X : Help for Far End
View in Manager Options is unavailable in RRI Manager
- Pronto # 9483ES05X : RRI_EMA: click on
OK button of Configuration- Settings - Outdoor Unit1 dialogue leads to
manager crash.
- Pronto # 9611ES05X : SW activation is
not happening via SW upgrade dialogue.
- Pronto # 9581ES05X : USMGR OK button is
enabled on Traffic Manager when conflict is present
- Pronto # 9474ES05X : US_EMA Conflict is
not getting detected for imported files
- Pronto # 6537ESPE06 : OU settings not
changed when far-end OU is in FB2
- Pronto # 6044ESPE06 : MH Manager crashs when protected XC condition bit values are selected
- Pronto # 7394ESPE07 : Near-end scrambler
polynom not changed when using MetroHub manager
far-end settings dialog
- Pronto # 9767ES05X : MHMGR: Manager
crashing when OU Settings-Interleave status is changed
- Pronto # 8983ES05X : Resource Conflict
is not indicated when 8k CC is created on even numbered bit.
- Pronto # 15055ESPE01: Traffic Manager
allows Invalid configurations
- Pronto # 9655ES05X : Far End Indoor Unit
is shown as '?' in far end view of Metrosite
- Pronto # 5327C01 : Saving of the PM data
is not aborted in case of interruption in management connection
- Pronto # 22466ES11P : After a software
download to a radio is aborted the selection of the alarm window results
in an 'Could not sent command'
- Pronto # 9793ES05X : US/MH: Manager
crashes when imported .abs file (Dbus).
- Pronto # 6687ESPE06: FB capacity doesn't
change when changing modulation from OU settings and capacity needs to be
changed at the same time.
- Pronto # 6688ESPE06: The maximum tx power is not set correctly when commissioning a metrohub with a node file.
The Element Manager changes in release
7.0 (build 7.0.8) are:
Features Added
Features Modified
Requirements implemented
- Migrated the Help from Win Help to chm
format.
- Look & Feel of the EM will be as per
the look & Feel of the respective OS
Bugs Fixed
The Element Manager changes in release
7.0 (build 7.0.9) are:
Requirements Implemented
- “Nokia Siemens Networks”
folder shall be in ‘Start’ menu instead of
‘Start->Programs’ menu.
Features Removed
Features Added
Features Modified
Bugs Fixed
Back to Contents
Known Issues
The following issues are known for this
Element Manager version:
Back to Contents
Other Information
Product codes for some of the products:
|
Product
|
Code
|
|
LMP Cable
|
CS 72451.01 / T55270.01
|
|
SiteWizard
6 CD4.0 (via NOLS)
|
471919A.105
|
|
SiteWizard
6 CD4.0 (CD-ROM)
|
471918A.105
|
Pentium is a trademark of Intel Corporation.
Windows Vista, Windows 2003, Windows 2000
and Windows XP are registered trademarks of Microsoft Corporation.
Other products may be trademarks or
registered trademarks of their respective manufacturers.
© 2009 Nokia Siemens Networks. All rights
reserved.
Nokia Siemens Networks operates on a
policy of continuous improvement. Therefore we reserve the right to make
changes and improvements to any of the products described in this guide without
prior notice.
Nokia Siemens Networks is not responsible
for any loss of data, income or any consequential damage howsoever caused.
Back to Contents