<?xml version="1.0" encoding="utf-8" standalone="yes"?><html xmlns="http://www.w3.org/1999/xhtml">
<head>
<title>Impact on NetAct products</title>
<meta content="text/html; charset=utf-8" http-equiv="Content-Type" />
<meta content="text/css" http-equiv="Content-Style-Type" />
<script src="NED?action=retrieve&amp;identifier=dn00188761&amp;edition=1&amp;language=none&amp;coverage=global&amp;encoding=javascript&amp;component=data&amp;item=data" type="text/javascript" xml:space="preserve">
</script>
<?conversion name="Pub2XHTML" version="2.0" source="urn:mars:dn03501863:2:en:global:publishing_online_1_0:data:data:*:*:*" date="2005-02-17T16:11:05Z"?>
<link href="NED?action=retrieve&amp;identifier=dn01158124&amp;edition=1&amp;language=en&amp;coverage=global&amp;encoding=css&amp;component=data&amp;item=data" rel="stylesheet" title="Nokia Networks default online style" type="text/css" />
<meta content="draft" name="status" />
<?conversion name="SplitHTML" version="1.9" source="urn:mars:dn03501863:2:en:global:publishing_online_1_0:data:data:6:*:*" date="2005-02-17T16:11:05Z"?>
</head>
<body lang="en" xml:lang="en">
<p><a name="sep2831552316" shape="rect"></a>
<a name="ned_15" shape="rect"></a></p>

<div class="div">
<table width="100%">
<tr>
<td align="center" colspan="1" rowspan="1" width="20%"><?NED5 annotation?>
<br clear="none" /><?NED5 printview?>
</td>
<td align="center" colspan="1" rowspan="1" width="20%"></td>
<td align="center" colspan="1" rowspan="1" width="20%"></td>
<td align="center" colspan="1" rowspan="1" width="20%"><a href="NED?action=retrieve&amp;identifier=dn03501863&amp;edition=2&amp;language=en&amp;coverage=global&amp;encoding=xhtml_1_0&amp;component=data&amp;item=data&amp;pointer=ned_1#ned_1" onclick="sync(this);return true" shape="rect">System impact of Automated Planning Enhancements</a></td>
<td align="center" colspan="1" rowspan="1" width="20%"><a href="NED?action=retrieve&amp;identifier=dn03501863_about&amp;edition=2&amp;language=en&amp;coverage=global&amp;encoding=xhtml_1_0&amp;component=data&amp;item=data&amp;pointer=ned_top#ned_top" onclick="openSmallPopup(event,'NED?action=retrieve&amp;identifier=dn03501863_about&amp;edition=2&amp;language=en&amp;coverage=global&amp;encoding=xhtml_1_0&amp;component=data&amp;item=data&amp;pointer=ned_top#ned_top');return false" shape="rect" target="_blank"><img alt="Document information" border="0" class="Metainfo" src="NED?action=retrieve&amp;identifier=dn01158003&amp;edition=1&amp;language=en&amp;coverage=global&amp;encoding=gif&amp;component=data&amp;item=data" /></a></td>
</tr>
</table>


<div class="div">
<h2>Impact on NetAct products</h2>

<a name="jan841324262" shape="rect"></a>
<div class="topic">
<h3>NetAct
Planner</h3>
</div>


<p>No impact.</p>


<a name="jan841325405" shape="rect"></a>
<div class="topic">
<h3>NetAct
Radio Access Configurator</h3>

<p>The MBAL object and related parameters can be managed only
with RAC, except for the BTS parametr <span class="parameter-sem">Measurement List
Used During Measurements</span> that is manageable with both NetAct and MML
commands.</p>
</div>


<a name="jan124133501" shape="rect"></a>
<div class="topic">
<h3>NetAct
Measurement Manager</h3>

<p>Defining the measurement period and activating the measurement
collection in BSC</p>
</div>


<a name="jan124134242" shape="rect"></a>
<div class="topic">
<h3>NetAct
Reporter</h3>

<p>Storing the measurement data into NetAct database from
BSCs</p>


<p>Automated Planning Enhancement measurements may cause additional
load to PM database if Channel Finder, Defined Adjacent Cell and FEP measurements
are retrieved hourly.</p>
</div>


<a name="jan124135343" shape="rect"></a>
<div class="topic">
<h3>NetAct
Optimizer</h3>

<p>Optimizer retrieves measurement data automatically from
NetAct PM database and configuration data from CM database and generates cell
pair interference probability on the basis of that information. The interference
information is used in the integrated frequency allocation tool in Optimizer.
The new frequency and BSIC plan is automatically stored in NetAct CM database
waiting for provisioning.</p>


<p>The interference matrix can be visualized and verified in Optimizer
so that, for example, the interfering cells are shown, the cells not measured
are identified, and measurement validity evaluated. It is essential to ensure
that the measurements are complete before using them in frequency allocation.</p>


<p>Optimizer supports Automated Planning Enhancements in two ways. The
FEP measurement can be used as the source for interference matrix instead
of CF and DAC measurements. Optimizer provides the means to define the Measurement
BA list content, define the amount of neighouring cell BCCHs kept in the BA
list during measurements and means to rank the adjacencies based on HO statistics.
When managing the BA lists in Optimizer it is also possible to ensure that
the automated BA list circulation process does not generate lists including
illegal channel amount combinations in dual band case (<em>3GPP TS 44.018</em>)</p>
</div>
</div>
</div>
</body>
</html>