    This file contains information on the following subjects:               
   
    1. Release notes for R09.00.01
 
    2. Creating a new embassy customer directory using the sample 
       embassy data SMP_EMB. 
 
    3. Guidelines for proper installation of ASN or SP tone_dc databases. 
 
------------------------------------------------------------------------------- 
1. Release notes for R09.00.01 
 
The Centracom Series II Plus Field Prom Programming Software Manual
(part number 68-81121E49-F) has a misprint on page IV-57. It reads as 
follows:

"For ASTRO signalling the individual ID must be a 7-digit decimal number 
greater than zero. The talk group ID entered must be a 4-digit decimal
number between 0001 and 4095 that is prefixed by the system with "A00".

The following should replace the above statement:

"For ASTRO signalling the individual ID must be a 7-digit decimal number 
greater than zero. The talk group ID entered must be a 4-digit decimal
number between 0001 and 4094 (inclusively) that is prefixed by the system 
with "A00".

------------------------------------------------------------------------------- 
           
2.  Guidelines for creating a new EMBASSY customer. 
    ----------------------------------------------- 
 
    A CEB template, CEB2, is provided with the SMP_EMB sample embassy 
    customer data.  This template contains only one CRT operator position 
    with no channels or other data. 
 
    You can create a new embassy customer from this CEB2 data template 
    with the following steps.  
     
    A. Create a new AEB directory using the DOS command 'md'. 
       Eg., C:\>MD NEW_AEB 
 
 
    B. Then go to that new directory. 
       Eg., C:\>CD NEW_AEB 
 
 
    C. Make all of the CEB directories off of the AEB directory, 
       Eg., C:\NEW_AEB>MD CEB1 
            C:\NEW_AEB>MD CEB2 
            etc. 
                          ------- 
                          | C:\ | 
                          ------- 
                             | 
                        ------------ 
                        | NEW_AEB  |    
                        ------------ 
                       /     |      \ 
                     /       |       \ 
               --------   --------    -------- 
               | CEB1 |   | CEB2 |    | CEBn | 
               --------   --------    -------- 
     
    D. From your AEB directory copy the NEW_TRK file from the sample 
       data's AEB directory to TRK_RED. 
       Eg.,  C:\NEW_AEB>COPY \SMP_EMB\NEW_TRK TRK_RED 
 
       This example assumes that the sample data is located on the  
       same disk drive as your new AEB. 
 
       This is the only file you will need from the sample AEB  
       directory.  The other files will be created. 
     
     
    E. Copy all of the files from the CEB template directory to all 
       of your CEB directories. 
       Eg., C:\NEW_AEB>COPY \SMP_EMB\CEB2 CEB1 
            C:\NEW_AEB>COPY \SMP_EMB\CEB2 CEB2 
            etc. 
 
          
    F. You must now give each CEB a unique ID before adding/changing 
       data in your new embassy system (after step 'E' each CEB will have 
       a CEB ID of 2).  Using the FPP change the CEB ID for each CEB,  
       menu 0498. 
 
                                                
------------------------------------------------------------------------------- 
 
 
3.  Guidelines for proper installation of ASN or SP tone_dc databases         
    ----------------------------------------------------------------- 
                             
 
    INTRODUCTION:  
 
       A tone_dc database is a group of tones delivered by a particular base  
    station at specific frequencies or DC currents.  
       This file outlines the steps in choosing a tone_dc database that is 
    best suited for a given system configuration. 
 
 
    A)  Once all current Personality Proms are downloaded into the FPP 
        the TDM address which requires the ASN or sp tone_dc can be modified. 
 
  
    B)  Select one of the following databases for the TDM slot that requires 
        an ASN or sp tone_dc database. 
 
        1.  FILE NAME => TONE_DC.SPA 
 
            a. SP 1 will provide the TDM with a T1 standard CCM to Key on 
               Freq. 4 function tone(1250Hz) or Freq. 4 DC current(-12.5ma). 
 
                       VALUE                  TONE FREQUENCY 
                    
               tone1  : ORD(sq_dsb)              2050 Hz 
               tone2  : $FF                      1950 Hz 
               tone3  : ORD(pl_str_f1)           1850 Hz 
               tone4  : ORD(r2_off)              1750 Hz 
               tone5  : ORD(r2_on)               1650 Hz 
               tone6  : ORD(rptr_off)            1550 Hz 
               tone7  : ORD(rptr_on)             1450 Hz 
               tone8  : $FF                      1350 Hz 
               tone9  : ORD(freq1)               1250 Hz 
               tone10 : ORD(wcii_on)             1150 Hz 
               tone11 : ORD(wcii_off)            1050 Hz 
               tone12 : ORD(pl4)                  950 Hz 
               tone13 : ORD(pl1)                  850 Hz 
               tone14 : ORD(pl2)                  750 Hz 
               tone15 : ORD(pl3)                  650 Hz 
   
            b. SP 2 will provide the TDM with a T1 standard CCM to key on 
               Freq. 3 function tone(1350Hz) or Freq. 3 DC current(-5.5ma). 
 
                       VALUE                  TONE FREQUENCY 
                    
               tone1  : ORD(sq_dsb)              2050 Hz 
               tone2  : $FF                      1950 Hz 
               tone3  : ORD(pl_str_f1)           1850 Hz 
               tone4  : ORD(r2_off)              1750 Hz 
               tone5  : ORD(r2_on)               1650 Hz 
               tone6  : ORD(rptr_off)            1550 Hz 
               tone7  : ORD(rptr_on)             1450 Hz 
               tone8  : ORD(freq1)               1350 Hz 
               tone9  : $FF                      1250 Hz 
               tone10 : ORD(wcii_on)             1150 Hz 
               tone11 : ORD(wcii_off)            1050 Hz 
               tone12 : ORD(pl4)                  950 Hz 
               tone13 : ORD(pl1)                  850 Hz 
               tone14 : ORD(pl2)                  750 Hz 
               tone15 : ORD(pl3)                  650 Hz 
 
            c. SP 3 will provide the TDM with a T1 standard CCM to Key on 
               Freq. 2 function tone(1850Hz) or Freq. 2 DC current(12.5ma). 
 
                       VALUE                  TONE FREQUENCY 
                    
               tone1  : ORD(sq_dsb)              2050 Hz 
               tone2  : $FF                      1950 Hz 
               tone3  : ORD(freq1)               1850 Hz 
               tone4  : ORD(r2_off)              1750 Hz 
               tone5  : ORD(r2_on)               1650 Hz 
               tone6  : ORD(rptr_off)            1550 Hz 
               tone7  : ORD(rptr_on)             1450 Hz 
               tone8  : ORD(wci_on)              1350 Hz 
               tone9  : ORD(wci_off)             1250 Hz 
               tone10 : ORD(wcii_on)             1150 Hz 
               tone11 : ORD(wcii_off)            1050 Hz 
               tone12 : ORD(pl4)                  950 Hz 
               tone13 : ORD(pl1)                  850 Hz 
               tone14 : ORD(pl2)                  750 Hz 
               tone15 : ORD(pl3)                  650 Hz 
 
        2. FILE NAME => TONE_DC.SPB 
 
            a. SP 3 will provide the TDM with a T4 CCM to be able to send  
               4PL control codes as function tones for key on Freq. 1(1350Hz) 
               key on Freq. 2(1250Hz), key on Freq. 3(1150Hz), and key on 
               Freq. 4(1050Hz).  NOTE: Tone Only 
 
                       VALUE                  TONE FREQUENCY 
                    
               tone1  : ORD(sq_dsb)              2050 Hz 
               tone2  : ORD(pl1)                 1950 Hz 
               tone3  : ORD(pl2)                 1850 Hz 
               tone4  : $FF                      1750 Hz 
               tone5  : $FF                      1650 Hz 
               tone6  : ORD(rptr_off)            1550 Hz 
               tone7  : ORD(rptr_on)             1450 Hz 
               tone8  : ORD(freq1)               1350 Hz 
               tone9  : ORD(freq2)               1250 Hz 
               tone10 : ORD(freq3)               1150 Hz 
               tone11 : ORD(freq4)               1050 Hz 
               tone12 : ORD(pl4)                  950 Hz 
               tone13 : ORD(pl1)                  850 Hz 
               tone14 : ORD(pl2)                  750 Hz 
               tone15 : ORD(pl3)                  650 Hz 
 
            b. SP 2 will provide on/off repeat control on a T8 CCM. 
 
                       VALUE                  TONE FREQUENCY 
                    
               tone1  : ORD(sq_dsb)              2050 Hz 
               tone2  : ORD(freq1)               1950 Hz 
               tone3  : ORD(freq2)               1850 Hz 
               tone4  : ORD(freq7)               1750 Hz 
               tone5  : ORD(freq8)               1650 Hz 
               tone6  : ORD(rptr_off)            1550 Hz 
               tone7  : ORD(rptr_on)             1450 Hz 
               tone8  : ORD(freq3)               1350 Hz 
               tone9  : ORD(freq4)               1250 Hz 
               tone10 : ORD(freq5)               1150 Hz 
               tone11 : ORD(freq6)               1050 Hz 
               tone12 : ORD(pl4)                  950 Hz 
               tone13 : ORD(pl1)                  850 Hz 
               tone14 : ORD(pl2)                  750 Hz 
               tone15 : ORD(pl3)                  650 Hz 
 
        3.  FILE NAME => TONE_DC.ASN 
             
            This file basically contains the same tones as the old tone_dc 
            file, except for the addition of ASN tones to the following tone 
            tables: 
 
            a. T1 Standard will provide the TDM with a T1 standard CCM to 
               send the following: Mute Receiver R2 or Select Key 5 tone 
               at 1750Hz, Unmute Receiver R2 or Select Key 6 tone at 1650Hz, 
               Wild Card I On or Select Key 7 tone at 1350Hz, Wild Card I Off 
               or Select Key 8 tone at 1250Hz, Select Key 4 tone at 950Hz, Select 
               Key 1 tone at 850Hz, Select Key 2 tones at 750Hz, and Select 
               Key 3 tone at 650Hz. 
 
                       VALUE                  TONE FREQUENCY 
                    
               tone1  : ORD(sq_dsb)              2050 Hz 
               tone2  : ORD(freq1)               1950 Hz 
               tone3  : ORD(pl_st_f1)            1850 Hz 
               tone4  : ORD(r2_off)              1750 Hz 
               tone5  : ORD(r2_on)               1650 Hz 
               tone6  : ORD(rptr_off)            1550 Hz 
               tone7  : ORD(rptr_on)             1450 Hz 
               tone8  : ORD(wci_on)              1350 Hz 
               tone9  : ORD(wci_off)             1250 Hz 
               tone10 : ORD(wcii_on)             1150 Hz 
               tone11 : ORD(wcii_off)            1050 Hz 
               tone12 : ORD(pl4)                  950 Hz 
               tone13 : ORD(pl1)                  850 Hz 
               tone14 : ORD(pl2)                  750 Hz 
               tone15 : ORD(pl3)                  650 Hz 
 
            b. T2 Standard will provide the TDM with a T2 standard CCM to 
               send the following: Mute Receiver R2 or Select Key 5 tone 
               at 1750Hz, Unmute Receiver R2 or Select Key 6 tone at 1650Hz, 
               Wild Card I On or Select Key 7 tone at 1350Hz, Wild Card I Off 
               or Select Key 8 tone at 1250Hz, Select Key 4 tone at 950Hz, Select 
               Key 1 tone at 850Hz, Select Key 2 tones at 750Hz, and Select 
               Key 3 tone at 650Hz. 
 
                       VALUE                  TONE FREQUENCY 
                    
               tone1  : ORD(sq_dsb)              2050 Hz 
               tone2  : ORD(freq1)               1950 Hz 
               tone3  : ORD(freq2)               1850 Hz 
               tone4  : ORD(r2_off)              1750 Hz 
               tone5  : ORD(r2_on)               1650 Hz 
               tone6  : ORD(rptr_off)            1550 Hz 
               tone7  : ORD(rptr_on)             1450 Hz 
               tone8  : ORD(wci_on)              1350 Hz 
               tone9  : ORD(wci_off)             1250 Hz 
               tone10 : ORD(wcii_on)             1150 Hz 
               tone11 : ORD(wcii_off)            1050 Hz 
               tone12 : ORD(pl4)                  950 Hz 
               tone13 : ORD(pl1)                  850 Hz 
               tone14 : ORD(pl2)                  750 Hz 
               tone15 : ORD(pl3)                  650 Hz 
 
            c. T4 Standard will provide the TDM with a T4 standard CCM to 
               send the following: Select Key 4 tone at 950Hz, Select 
               Key 1 tone at 850Hz, Select Key 2 tone at 750Hz, and Select 
               Key 3 tone at 650Hz. 
 
                       VALUE                  TONE FREQUENCY 
                    
               tone1  : ORD(sq_dsb)              2050 Hz 
               tone2  : ORD(freq1)               1950 Hz 
               tone3  : ORD(freq2)               1850 Hz 
               tone4  : ORD(r2_off)              1750 Hz 
               tone5  : ORD(r2_on)               1650 Hz 
               tone6  : ORD(rptr_off)            1550 Hz 
               tone7  : ORD(rptr_on)             1450 Hz 
               tone8  : ORD(freq3)               1350 Hz 
               tone9  : ORD(freq4)               1250 Hz 
               tone10 : ORD(wcii_on)             1150 Hz 
               tone11 : ORD(wcii_off)            1050 Hz 
               tone12 : ORD(pl4)                  950 Hz 
               tone13 : ORD(pl1)                  850 Hz 
               tone14 : ORD(pl2)                  750 Hz 
               tone15 : ORD(pl3)                  650 Hz 
 
            NOTE: TONE_DC.SPA and TONE_DC.SPB also contain the above ASN 
                  tones in the respective tone tables. 
  
 
    C)  Copy the desired database from Disk 5 to the customer's DATA directory  
        into the tone_dc database.  
 
            a. Log into drive which contains the customers directory. 
                       
                   Example => If the directory is in the C drive then     
                              move to the C prompt(C:). 
                    
            b. Change directories to the Customers Data directory. 
 
                   Example => CD <customers directory pathname>           
 
            c. Copy the current tone_dc file in the customers directory to 
               tone_dc.old. 
 
                   Example => Copy tone_dc tone_dc.old 
 
            d. Copy the selected ASN or sp tone_dc file from Disk 5 into the 
               customer's directory. 
 
                   Example => (Assuming Disk 5 is in Drive A and that you are 
                              currently in the customers data directory which  
                              is on Drive C.) 
                                 
                              Copy A:tone_dc.spa tone_dc 
 
                                                                         
    D)  Edit Base Station type of TDM requiring the ASN or SP tone_dc database. 
 
            a. Invoke the FPP program with the associated customer's   
               Data directory. 
        
            b. Select "F4 = Change/Create/View console codeplug data" from the 
               MAIN MENU.  
 
            c. Select "F4 = Reconfigure TDM slots in CEB" from the  
               CHANGE DATABASES MENU.                              
            
            d. Select "F2" to edit the TDM which requires the tone_dc 
               database. 
            
            e. Edit the "Base Station Type" to either T1 Standard, T2 Standard, 
               T4 Standard, SP 1, SP 2 or SP 3.  
               Refer to part B for definitions of the ASN/SP databases.      
 
 
    E)  Refer to sample Data for Examples on Sp tone_dc databases. 
 
            a. TDM 40 is equipped to key on Freq. 4 function tone(1250Hz). 
 
            b. TDM 20 is equipped to key on Freq. 2 DC current(12.5ma). 
 
            c. TDM 21 is equipped to key on Freq. 2 function tone(1850Hz). 
         