  0)Select OP Position TDM Slot Number: 
  1)Enter Alias Type 
  2)Aliasing Information for Channel
  3)Aliasing Information for Trunking Unit
  4)Aliasing Information for RF Signalling Unit
  5)Enter up to 8 Character Alias: 
  6)Enter Channel Type (1=Conv., 2=Trunking, 3=Private Call 4=Deassign): 
  7)BID Code: 
  8)Trunking System ID : 
  9)Trunking Fleet     : 
 10)Trunking Subfleet  : 
 11)Trunking Individual: 
 12)Failsoft TDM Slot  : 
 13)Regroupable (Y/N)  : 
 14)Enter RF Signalling 7 Digit Unit ID: 
 15)Number of Aliases Left: 
 16)Current Number of Aliases: 
 17)Do you wish to save your changes
 18)for OP Position %s (Y/N): 
 19)*SIG_OPID
 20)Select OP position TDM slot number: 
 21)Enter RF Signalling Modem TDM slot: 
 22)Are All Individual OPIDs the same(S) or different(D)
 23)  for this modem across ops in this system? (S or D):
 24)Enter Individual Operator ID for Selected Modem and OP: 
 25)Enter Talk Group ID for Selected Modem and OP: %X
 26)Do you really want to change OPIDS system-wide?(Y or N):
 27)Do you really want to change INDIVIDUAL IDS system-wide?(Y or N):
 28)Do you really want to change GROUP IDS system-wide?(Y or N):
 29)Please verify - do you want to change op positions?(Y or N):
 30)Do you wish to save your changes for this op position?(Y or N):
 31)(1=Unit Id, 2=Channel Name, 3=Unchanged):
 32)Do you wish to save your changes
 33)Select OP Position TDM Slot Number: 
 34)Brightness Level for all DCCMs on Selected Op (1 - 5): 
 35)for OP Position %s (Y/N): 
 36)for OP Position %s before you exit (Y/N): 
 37)Valid Brightness Levels are 1 to 5 only.
 38)SMARTNET System Type (1=Type I, 2=Type II, 3=Type I Aliased): 
 39)Private Call Capable? (Y/N)   : 
 40)Private Call Enhanced (Ring Enabled)? (Y/N)  : 
 41)Individual ID  : 7
 42)Fleet or Subfleet? (F/S): 
 43)Group ID       : 80
 44)SMARTNET System Type (1=Type I, 2=Type II): 
 45)Do you have an ENTER ID (K519) switch? (Y/N): 
 46)Enter Mobiles/Portables Type (1=PCII, 2=PCII Enhanced, 3=APC):
 47)Enter Operator Status Number for Selected Modem and OP:
 48)*OPSTAT_NUM
 49)Enter RF Signalling System id (0 or 1):
 50)Initial Display Type After Unselecting Channels
 51)Initial Display Type After Selecting Channels
 52)Select Location and Character for Primary Channel Indicator:
 53)Valid Channel Types are 1 to 3 only.
 54)Valid Response is one character in one position.
 55)WARNING: space is a valid primary channel indicator.
 56)Are you sure you want to delete this entry? (Y/N): 
 57)     DIALER Alias Name        Phone Number     
 58)     -----------------    --------------------
 59)Failsoft Rptr Num  : 
 60)CEB_ID:
 61)AEB_ID:
 62)*RF SIGNALLING MENU
 63)CHANGE RF SIGNALLING MENU
 64)F1 = Help
 65)F2 = Change RF Signalling Operator IDS 
 66)F3 = Change RF Signalling Bim Parameters
 67)F4 = Change Data Logger Partitioning
 68)F5 = 
 69)F6 = 
 70)F7 = 
 71)F8 = 
 72)F9 = 
 73)F10 = Exit
 74)*rf channel busy criteria fields
 75)Select RF Signalling Modem TDM Slot:
 76)*modem tdm slot field
 77)RF Channel Busy Criteria is Based on:
 78)Carrier Operated Relay (y or n):
 79)Lack of Channel Free Tone (y or n):
 80)Enter Channel Free Tone Frequency (1200):
 81)Integrated Voice Activity (y or n):
 82)Enter Voice Activity Drop-out Time (100 to 10000 ms in 100 ms steps):
 83)*voice activity integration time field
 84)Enable the Channel Busy Wait Timer (y or n):
 85)Is the Base Station Wire Line Full Duplex? (y or n):
 86)Enter Pre-Time Delay (0 to 1500 ms in 100 ms steps):
 87)Enter the Acknowledgement Delay (0 to 3000 ms in 100 ms steps):
 88)Enter a Constant to Determine the Length of the Retry Delay (2 to 17):
 89)Enter the Intersequence Delay (10 to 2500 ms in 10 ms steps):
 90)Enter the DOS Muting Hold-Out Delay (10 to 1500 ms in 10 ms steps):
 91)Enter the DOS Coast Time (0 to 1000 ms in 10 ms steps):
 92)Send PTT ID for Voice Transmissions (y or n):
 93)Enable TX Display (y or n):
 94)Enter Stack Size (2-10):
 95)Enable Selective Signalling Muting on this BIM (y or n):
 96)Repeater Access Type (A=Auto. M=Man. N=None):
 97)Enter Access Code:
 98)Repeater Access Pre-Time (300 to 1500 ms in 100 ms steps):
 99)Generate Closure for Sending Data on a Coded Channel (y or n):
100)Enter Desired Display System Number (0 to %d):
101)*CHANGE_ALIASING_MENU
102)CHANGE ALIASING MENU
103)F1 = Help
104)F2 = Assign DCCM Aliases
105)F3 = Update Dialer Aliases
106)F4 = 
107)F5 = 
108)F6 = 
109)F7 = 
110)F8 = 
111)F9 = 
112)Change Aliasing Menu
113)Enable Stack Delete and Update RCVD LED on
114)Parallel Operator Positions (y or n): 
115)Enter Talk Group ID for Selected Modem and OP:
116)  (1=Channel, 2=Trunk Unit, 3=MDC Unit, 4=Select V Unit, 5=ASTRO Unit): 
117)Enter Stack Size for Talkgroups/Subfleets (2-10):
118)LIFD or FIFD Stacking for Talkgroups/Subfleets (L or F):
119)Enter Stack Size for Multigroups/Fleetwide (2-10):
120)LIFD or FIFD Stacking for Multigroups/Fleetwide (L or F):
121)Enter Stack Size for PCIIE's (2-10):
122)LIFD or FIFD Stacking for PCIIEs (L or F):
123)25)Enter Talk Group ID for Selected Modem and OP: %X00